Plasmonic-based impedance microspectroscopy of optically heterogeneous samples.

Sidahmed A Abayzeed1.   

Abstract

A robust impedance microscopy technique is presented. This optical tool enables high resolution imaging of electrical properties with promising biophysical applications. The underlying principle is that surface plasmon resonance (SPR) sensors are able to measure perturbations of surface charge density and therefore can be used to compute the impedance of surface-adhered cells. However, the ability to perform reliable quantitative impedance imaging is affected by the optical heterogeneity of the cell-sensor interface. To address this issue, a novel method for quantitative time-resolved resonance angle tracking is developed and applied to correct for the effect of the optical properties. To demonstrate the capability of this technique, impedance microspectroscopy of bovine serum albumin (BSA) patterns was performed enabling measurements of capacitance with submicroscopic resolution. The work presented offers an impedance microspectroscopy method that will create new avenues in studying the electrical properties of single cells and biomolecules as well as bio-electrical currents. Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI.

Entities:  

Year:  2020        PMID: 33282482      PMCID: PMC7687972          DOI: 10.1364/BOE.395474

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


Introduction

Current biomedical challenges require extensive research efforts to widen the reach of optical microscopy to probe chemical [1,2], mechanical [3] or electrical properties of cells and tissue samples [4]. A significant advancement in sub-microscopic imaging of electrical current was made by Tao and colleagues using surface plasmon resonance (SPR) microscopy [5,6]. Based on this method, a scan-free impedance microscopy technique was developed and applied to study cellular processes such as apoptosis [6] and cell signaling [7]. The method has also been applied, by Gheorghiu’s group, to study molecular interactions in comparison with standard SPR sensing [8]. Impedance spectroscopy of adherent cells, a method that was developed in a pioneering work by Giaever and Keese, demonstrated a great success as a cell assay [9] with applications in monitoring of stem cell differentiation [10], studying signal transduction [11] and characterizing epithelial barrier function [12]. As well as providing complementary information to the present impedance sensing techniques [13,14], the emerging plasmonic-based technique creates new avenues to study electrical heterogeneity at the sub-cellular level. In a typical impedance spectroscopy system, the impedance of a population of adherent cells is measured using a two-electrode (i.e. working and reference electrode) configuration [14]. A small alternating voltage is applied between these electrodes, for a set of frequencies, while measuring current flow across the sample. The resulting impedance spectrum is used to construct the sample equivalent electrical network [9] and characterise the behavior of the cell population under different conditions. Recently, spatially-resolved impedance spectroscopy has been developed using micro-fabricated electrodes [15] or field-effect transistors [16,17], with a resolution that goes down to a single cell [17]. Extending the capabilities of these approaches to perform measurements at a smaller scale promises enhanced sensitivity and the ability to characterize sub-microscopic structures. Furthermore, performing high resolution impedance measurements using an optical microscopy method would allow the integration with standard microscopy techniques. This, in particular, supports the trend of developing information-rich bioimaging systems with the ability to perform spectroscopic measurements with sub-cellular resolution. Plasmonic-based optical measurements of the electrical impedance was demonstrated by imaging a pattern of 1-dodecanethiol (DDT) printed on the gold surface [5]. The work was followed by implementing a widefield SPR microscopy method to monitor the dynamic impedance of living cells [6,18]. The underpinning principle of this method is that SPR sensors are sensitive to charge density modulation and therefore are able to detect voltage optically and without fluorescent labels [19,20]. Externally-applied voltage alters the charge density at metal-electrolyte interface which changes the resonance conditions, as a result [19]. Thus, SPR sensors can be seen as two-dimensional electrodes with optical readout in addition to their ability to spatially resolve electrical current. A widefield SPR microscopy system was used to image local charge density modulation and compute electrochemical impedance at a sub-micrometer scale [6]. In such an optical arrangement [21,22], the sample is illuminated with a collimated beam, fixed at a specific angle of incidence normally at the highest gradient of the SPR curve, as shown in Fig. 1. This approach transforms the changes in resonance angle to pixelated changes in reflectivity in a scan-free manner as illustrated in Fig. 1-(b). Using this setup, a map of electrical impedance of surface-adhered objects can be computed, with the knowledge of the applied voltage (V) and the experimental resonance angle modulation () at the angular frequency (), using this expression [6]: where is a parameter that relates the resonance angle modulation to charge perturbation at the sensor-sample interface, =, , and are complex quantities. The estimation of the parameter is discussed in detail in the results section. As described by Eq. (1), one needs to obtain quantitative information on the spatial variation of the voltage-modulated resonance angle. This information is used to compute charge density modulation, given by this term: . The measured local charge density provides information about the local impedance of the sample.
Fig. 1.

(a) A diagram describes the optical configuration for widefield SPR microscopy. Linearly-polarized light is focused on the BFP to produce a collimated beam on the image plane (i.e. the sensor surface) and the spot on the BFP is translated radially to scan the angle of incidence. A two-electrode configuration is also illustrated where gold thin film is used as an electrode; drawing is not to scale. (b) The sketch shows the transformation of resonance angle modulation to a pixelated change in the reflected intensity, when the sample is illuminated at a fixed angle at the highest gradient of the SPR curve. (c) and (d) show how the response of the sensor (i.e. the gradient changes with refractive index, for a fixed angle of illumination.)

(a) A diagram describes the optical configuration for widefield SPR microscopy. Linearly-polarized light is focused on the BFP to produce a collimated beam on the image plane (i.e. the sensor surface) and the spot on the BFP is translated radially to scan the angle of incidence. A two-electrode configuration is also illustrated where gold thin film is used as an electrode; drawing is not to scale. (b) The sketch shows the transformation of resonance angle modulation to a pixelated change in the reflected intensity, when the sample is illuminated at a fixed angle at the highest gradient of the SPR curve. (c) and (d) show how the response of the sensor (i.e. the gradient changes with refractive index, for a fixed angle of illumination.) Quantifying the time-resolved resonance angle is not straightforward, since the angle scanning methods, which employ minimum finding algorithms [21,22], require recording a series of images and therefore are not suited to quantify the dynamic voltage signals. To overcome this issue, calibration between the resonance position shift and the reflectivity change is determined by Foley et al [5] and validated experimentally. This approach is applicable to specific scenarios where local variations of refractive index are negligible. Since, this calibration depends on the local gradient of the SPR curve, denoted by in this paper, it changes with the refractive index of the sample as described by Eq. (2). This can be understood by considering the case presented in Fig. 1(c) and (d) where a patterned layer of a dielectric material with a thickness of 10 nm and refractive index of 1.45 is attached to the gold surface in aqueous environment. In this case, the local gradient of the SPR curve (i.e. at a fixed angle of incidence) changes by approximately a factor of 3 when compared to the bare gold in contact with aqueous environment (refractive index 1.3329). This local variation in refractive index results in anomalies in impedance images, if it is not corrected. Accounting for the effect of the refractive index is essential when imaging the electrical properties of optically heterogeneous samples such as cells adhered to gold surface. For instance, inhomogeneous adhesion of cells on the sensor, in addition to variability in the optical properties of the cell membrane, results in a spatially heterogeneous refractive index at the cell-sensor interface. This problem becomes more significant when both optical and electrical properties [6,7] change over time resulting in a time-varying response of the sensor. Therefore, there is still a challenge to develop a resonance angle retrieval method that is suitable to the dynamic measurements of the voltage signal applied in the impedance microscopy. In this brief paper, a new method for quantitative time-resolved measurements of the resonance angle is presented and applied to plasmonic-based impedance imaging. A novel approach for dynamic plasmonic-based current density microscopy is presented using a gradient mapping technique. The method is described in the following analysis. For the low alternating voltage that is applied in impedance sensing, the spatio-temporal dynamics of the reflectivity, at a fixed angle of incidence, can be expressed as: where is the mean reflectivity at a fixed angle of incidence , is the spatially-variable refractive index and is the static impedance of the sample. (1/deg) is the local gradient of the SPR curve, (deg/V) is a factor that relates the resonance angle modulation to the applied voltage ; it depends on the local impedance of the sample. Changes in reflectivity [] can be correlated or anti-correlated to the resonance angle change for angles of illumination and respectively where represents the mean resonance angle, with the reflectivity change (i.e. gradient) approaches zero at this resonance position, as shown in Fig. 1-(d). Eq. (2) also states that the sensitivity of the method to probe localised electrical properties is affected by the value of the gradient of the SPR curve and therefore by the variations in refractive index, if a fixed angle of illumination is selected (Fig. 1-(d)). In order to obtain the resonance angle modulation, the change in reflectivity is divided by the gradient of the SPR curve at the angle of incidence of choice, as Where is reflectivity modulation obtained by taking the Fourier transform of Eq. (2). For this reason, the gradient of the SPR curve at the angle of illumination () is computed for each pixel to obtain the local response of the sensor and perform localized impedance measurements. Eq. (3) is based on the assumption that gradient does not change over time. This assumption only holds when measuring the static electrical properties of cells and it will be extended to develop a dynamic gradient mapping method in a subsequent work. This method is demonstrated by imaging the impedance of bovine serum albumin (BSA) patterns printed on the gold surface. This sample is selected to test for the effect of refractive index of the sample on the impedance measurements. It is also used to discuss the selection of the angle of incidence, since the variation in the refractive index results in attenuation of the sensitivity of the plasmonic-based impedance method.

Results and discussions

This section presents the gradient mapping as a method for quantitative time-resolved imaging using SPR microscopy. The method is used to compute the resonance angle modulation while canceling the effect of refractive index. The use of quantitative resonance angle information to calculate localised impedance of the sample is presented followed by discussions on the factors that affect the parameter ().

Gradient mapping

Impedance imaging of samples with spatially-variable refractive index, using widefield intensity-based SPR microscopy, requires computation of localised sensor response. This is found by mapping the gradient of the SPR curve at the angle of incidence of choice. This is achieved by stepping the angle of incidence by in the range of (). The gradient of the SPR curve at this angle is then found from the derivative of the experimental reflectivity as a function of the angle of incidence, as explained in more detail in Appendix C. Results obtained from mapping the gradient of the SPR curve are shown in Fig. 2. For BSA patterns printed on the surface of the gold thin film, SPR curves for both the background and the BSA pattern are presented in Fig. 2(a) fitted to theoretical curves. Theoretical and experimental gradient of the SPR curves are presented in Fig. 2(c), obtained by differentiating the reflectivity with respect to the angle of incidence. Fig. 2(a)-(c) are plotted only for illustration purposes to describe the gradient mapping method and the selection of the angle of incidence, however obtaining these curves is not necessary in an impedance imaging experiment.
Fig. 2.

Gradient mapping: (a) SPR curves for bare gold and BSA regions; (b) reflectivity map at =, (i.e. the operating point selected for the impedance measurements); (c) theoretical and experimental gradient of the SPR curves for Au and BSA; and (d) gradient map at =69.8. BSA regions can be distinguished from the negative gradient values in (d). Scale bar 8 m.

Gradient mapping: (a) SPR curves for bare gold and BSA regions; (b) reflectivity map at =, (i.e. the operating point selected for the impedance measurements); (c) theoretical and experimental gradient of the SPR curves for Au and BSA; and (d) gradient map at =69.8. BSA regions can be distinguished from the negative gradient values in (d). Scale bar 8 m. Maps of the reflectivity and the gradient are presented in Fig. 2(b) and (d) respectively, for the angle of incidence of that is used to perform the impedance imaging. These maps show that both the reflectivity and the gradient vary spatially due to the inhomogeneous refractive index of the sample which results in a spatially-variable response to the applied voltage. The contrast in these maps depends on the position of the angle of illumination. It is worth commenting on the selection of the angle of incidence as it is important for sensitive measurements of current density. To perform quantitative measurements of the electrical properties, this angle is set to a point at which both object and background can respond to the applied voltage. This means that the operating point (i.e. the angle of incidence) is not necessarily at the highest gradient for each of the two curves since they are located at two different angles (i.e. 68.5, from Fig. 2-(c)) respectively. For instance, if the first operating point (i.e. 68.5) is selected, the system will only report on the electrical properties of the gold electrolyte interface and the response approaches zero at the BSA patterns. For this reason, the operating point is selected at where both object and the background can respond to the applied voltage. The approach described above is required, in general, for experiments where signals from single cells are compared to the background.

Quantitative plasmonic-based impedance imaging

Microscopic impedance measurements are degraded by the undesired effects of the local optical properties. In this section, the gradient mapping method is presented as an effective way to suppress the effects of optical properties. A test sample of BSA patterns printed on the gold surface was used to demonstrate this concept. First, a quantitative image of the optical properties of this sample was computed as presented in Fig. 3-(a) by mapping the static resonance angle of the SPR curve. This information is obtained by scanning the angle of incidence and finding the minimum of the SPR curve at each pixel. This procedure gives the average resonance angle, which is not affected by the applied voltage since it only depends on the local optical properties of the sample. In this image, BSA patterns have a higher resonance angle compared to bare gold. Second, Eq. (1) was used to compute the impedance, with the knowledge of the applied voltage and the voltage-modulated resonance angle, as presented in Fig. 3-(b,c). Gradient mapping was implemented using Eq. (3) to obtain quantitative measurements of the voltage-modulated resonance angle. As shown in Appendix D, the latter quantity was used to compute microscopic current flow through the sample.
Fig. 3.

Plasmonic-based imaging of impedance of microscopic structures demonstrated with BSA patterns printed on the sensor surface: (a) quantitative image of the sample showing the static resonance angle that reflects the local refractive index; (b) and (c) are the impedance maps before and after correcting for the effect of the optical properties of the sample, the scale bar is 8m and the impedance is calculated per pixel - pixel size is 400 nm x 400 nm; (d) microscopic impedance spectrum of BSA and bare gold calculated at a single pixel level; (e) surface capacitance mapped by performing equivalent circuit analysis on impedance microspectroscopy data; and (f) the parameter () simulated for a range of wavelengths and compared to the theoretical expression.

Plasmonic-based imaging of impedance of microscopic structures demonstrated with BSA patterns printed on the sensor surface: (a) quantitative image of the sample showing the static resonance angle that reflects the local refractive index; (b) and (c) are the impedance maps before and after correcting for the effect of the optical properties of the sample, the scale bar is 8m and the impedance is calculated per pixel - pixel size is 400 nm x 400 nm; (d) microscopic impedance spectrum of BSA and bare gold calculated at a single pixel level; (e) surface capacitance mapped by performing equivalent circuit analysis on impedance microspectroscopy data; and (f) the parameter () simulated for a range of wavelengths and compared to the theoretical expression. The effect of the optical properties on the impedance is discussed in Fig. 3-(b,c). The resonance angle modulation that is computed with the assumption of a fixed gradient is presented in Fig. 3-(b) compared to the results of the gradient mapping method shown in Fig. 3-(c). As discussed in the previous section, the response of the sensor to the applied voltage is affected by local optical properties when the sample is illuminated at a fixed angle of incidence. The use of the gradient mapping accounts for the anomalies in the impedance maps due to the effect of the local optical properties. If this is not corrected, the impedance contrast obtained is strongly affected by the local gradient of the sample at the angle of incidence of choice. As observed in Fig. 3-(c) after correcting for the gradient effect, the impedance of the BSA patterns appears higher compared to the background, as one would expect. After this correction, BSA regions showed lower current density, compared to the background (Appendix D). This approach allows both object and the background to be studied simultaneously and can be used to improve the impedance imaging contrast presented in the previous study by Wang et al [6] while enabling a retrieval of reliable quantitative information. Accurate impedance microspectroscopy offers a novel tool for studying microscopic electrical properties of the sample under the test. In order to investigate the nature of the active and passive components constituting the total impedance, spatially-resolved impedance spectra were produced at the single pixel level. An example of both BSA and gold regions is shown in Fig. 3-(d). These results show that the capacitive properties dominate the impedance of the system in the frequency range from 1-100 Hz. Using the least squares method, both curves were fitted to this expression [23,24]: where is the constant phase element describing the capacitive properties of the interface and is a factor correcting for the roughness-induced distributed time constant of the interface, it takes values between 0–1 where zero accounts for the case of a pure resistance and 1 describes a pure capacitance. For the sensor used in these experiments, =0.84 obtained experimentally as described in Appendix D. This analysis is similar to constructing the equivalent circuit of the electrode-electrolyte interface using Randles model. This model represents the electrode as a capacitor in parallel to a charge transfer resistor and the group is in series connection with the solution that is modelled with a resistor. Applying this model to the obtained experimental results, the capacitive route has a dominant effect since it has a lower impedance compared to the charge transfer resistance within the applied frequency range where the contribution of the solution resistance is also negligible. The data analysis approach described above was performed for each pixel to map the interfacial capacitance presented in Fig. 3-(e). Estimation of double-layer capacitance from constant phase element () is described in Appendix D. Contrast in capacitance between BSA and the gold background is observed. This is expected since the protein deposits have a lower static permittivity compared to water molecules that make the dielectric material of the double layer capacitor of the gold electrolyte interface. The static permittivity of BSA is [25] and water has a static permittivity of . Another factor that contributes to the observed contrast in the capacitance is the effect of the thickness of the BSA layer (10 nm) compared to the size of a water molecule (0.5 nm). A simple estimate of BSA capacitance, assuming the layer forms a parallel-plate capacitor, results in 0.04  and this value is very close to the BSA capacitance in Fig. 3-(e). The reported capacitance value for gold electrolyte interface is in the range of 0.1 - 0.13  close to but lower than the previously reported [5,19]. The presence of contaminants from BSA during the printing process could result in deviation from the anticipated capacitance of the gold-electrolyte interface. These findings are extremely important in the context of biosensing of living cells. For instance, capacitance measurements are performed to characterise cells [10] and study processes such as exocytosis [26]. The ability to perform capacitance imaging promises to provide complementary spatially resolved information on the dynamics of cell membrane. To convert the voltage-modulated resonance angle to the equivalent charge density map, an analytical expression was derived previously by Foley et al [5] that is given by: where is the unit charge, is the thickness of the Thomas-Fermi length of the metal film, is electron density in the metal film, is permittivity of the glass substrate, is the permittivity of the sample and is the real permittivity of the metal film. Permittivity here refers to the optical permittivity. This expression (Eq. (5) is derived from the commonly-used dispersion relation of surface plasmons of a noble metal with a semi-infinite thickness. However, this dispersion relation does not consider the effect of the thickness of the gold thin film that is commonly used in SPR sensing [27]. The effect of the metal thickness is only included to the expression when the voltage effect on the electron density is considered as explained below. As shown in Eq. (5), the parameter () of the sensor depends on the electron density at the metal surface. This effect is confined to the sub-atomic layer of the metal film (i.e. Thomas-Fermi screening length [19]) in contrary to the assumption that voltage affects the electron density of the bulk metal. In this study, the parameter () of this sensor is investigated by modeling the voltage effect on SPR sensors combining a multilayer optical model of the sensing structure with the physical chemistry models of the double-layer capacitor at the sensor-electrolyte interface [19]. The results are presented in Fig. 3-(f) compared to the analytical expression Eq. (5) for a series of wavelengths. Other factors such as refractive index of the surface-adhered sample and the applied voltage were investigated but showed a negligible effect. The results presented in Fig. 3-(f) show a strong dependence on the wavelength, the value of () obtained from the numerical model for 633 nm is in a good agreement with the experimental value reported by Lu et al (see supplementary material of Ref. [28]). The discrepancy between the numerical modeling and the analytical expression is expected since the analytical expression is based on an approximated dispersion relation of surface plasmons. The value of () at 688 nm was used to compute the impedance images presented in Fig. 3.

Conclusion

The method described here can be applied to perform quantitative imaging of electrical current, either produced by electrically-active cell or used in impedance imaging applications. The reported impedance microscopy method offers a reliable and effective way for mapping electrical properties on a submicroscopic scale while removing the effect of optical heterogeneity. This new capability will have a significant impact on studying bioelectricity as well as dielectric properties of materials. The assumption that gradient does not change with time restricts the applicability of the method to imaging the static electrical properties of single cells. However, to study cellular processes such as proliferation and apoptosis [6] where both electrical and optical properties are time-varying, a dynamic gradient mapping is needed. This approach will be useful to compute the response of the sensor to perform measurements for samples with dynamic refractive index (i.e. time-varying gradient). The temporal correction of the gradient method is also important when studying electrochemical heterogeneity since redox reactions are expected to be associated with refractive index dynamics. The ability to perform localised impedance measurements opens new opportunities to study biological structures and processes that occurs at the subcellular scale as well as molecular interactions.
  24 in total

1.  Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing.

Authors:  S Gawad; L Schild; P H Renaud
Journal:  Lab Chip       Date:  2001-08-13       Impact factor: 6.799

2.  Surface plasmon resonance imaging using a high numerical aperture microscope objective.

Authors:  Bo Huang; Fang Yu; Richard N Zare
Journal:  Anal Chem       Date:  2007-02-20       Impact factor: 6.986

3.  Two-path impedance spectroscopy for measuring paracellular and transcellular epithelial resistance.

Authors:  Susanne M Krug; Michael Fromm; Dorothee Günzel
Journal:  Biophys J       Date:  2009-10-21       Impact factor: 4.033

4.  Electrical cell-substrate impedance sensing with field-effect transistors is able to unravel cellular adhesion and detachment processes on a single cell level.

Authors:  A Susloparova; D Koppenhöfer; J K Y Law; X T Vu; S Ingebrandt
Journal:  Lab Chip       Date:  2015-02-07       Impact factor: 6.799

5.  Use of electric fields to monitor the dynamical aspect of cell behavior in tissue culture.

Authors:  I Giaever; C R Keese
Journal:  IEEE Trans Biomed Eng       Date:  1986-02       Impact factor: 4.538

6.  Sensitive detection of voltage transients using differential intensity surface plasmon resonance system.

Authors:  Sidahmed A Abayzeed; Richard J Smith; Kevin F Webb; Michael G Somekh; Chung W See
Journal:  Opt Express       Date:  2017-12-11       Impact factor: 3.894

7.  Capacitance measurements reveal stepwise fusion events in degranulating mast cells.

Authors:  J M Fernandez; E Neher; B D Gomperts
Journal:  Nature       Date:  1984 Nov 29-Dec 5       Impact factor: 49.962

8.  Plasmonic-based electrochemical impedance spectroscopy: application to molecular binding.

Authors:  Jin Lu; Wei Wang; Shaopeng Wang; Xiaonan Shan; Jinghong Li; Nongjian Tao
Journal:  Anal Chem       Date:  2011-12-14       Impact factor: 6.986

9.  Single cells and intracellular processes studied by a plasmonic-based electrochemical impedance microscopy.

Authors:  Wei Wang; Kyle Foley; Xiaonan Shan; Shaopeng Wang; Seron Eaton; Vinay J Nagaraj; Peter Wiktor; Urmez Patel; Nongjian Tao
Journal:  Nat Chem       Date:  2011-01-23       Impact factor: 24.427

10.  Label-Free Imaging of Histamine Mediated G Protein-Coupled Receptors Activation in Live Cells.

Authors:  Jin Lu; Yunze Yang; Wei Wang; Jinghong Li; Nongjian Tao; Shaopeng Wang
Journal:  Anal Chem       Date:  2016-11-15       Impact factor: 6.986

View more
  1 in total

1.  Analysis of the surface plasmon resonance interferometric imaging performance of scanning confocal surface plasmon microscopy.

Authors:  Sorawit Tontarawongsa; Sarinporn Visitsattapongse; Suejit Pechprasarn
Journal:  Biomed Opt Express       Date:  2021-12-24       Impact factor: 3.732

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.