Abstract

A low electrode-electrolyte impedance interface is critical in the design of electrodes for biomedical applications. To design low-impedance interfaces a complete understanding of the physical processes contributing to the impedance is required. In this work a model describing these physical processes is validated and extended to quantify the effect of organic coatings and incubation time. Electrochemical impedance spectroscopy has been used to electrically characterize the interface for various electrode materials: platinum, platinum black, and titanium nitride; and varying electrode sizes: 1 cm2, and 900 microm2. An equivalent circuit model comprising an interface capacitance, shunted by a charge transfer resistance, in series with the solution resistance has been fitted to the experimental results. Theoretical equations have been used to calculate the interface capacitance impedance and the solution resistance, yielding results that correspond well with the fitted parameter values, thereby confirming the validity of the equations. The effect of incubation time, and two organic cell-adhesion promoting coatings, poly-L-lysine and laminin, on the interface impedance has been quantified using the model. This demonstrates the benefits of using this model in developing better understanding of the physical processes occurring at the interface in more complex, biomedically relevant situations.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16041993     DOI: 10.1109/TBME.2005.847523

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  83 in total

Review 1.  Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording.

Authors:  Anoop C Patil; Nitish V Thakor
Journal:  Med Biol Eng Comput       Date:  2016-01-11       Impact factor: 2.602

2.  Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity.

Authors:  Thomas J Oxley; Nicholas L Opie; Sam E John; Gil S Rind; Stephen M Ronayne; Tracey L Wheeler; Jack W Judy; Alan J McDonald; Anthony Dornom; Timothy J H Lovell; Christopher Steward; David J Garrett; Bradford A Moffat; Elaine H Lui; Nawaf Yassi; Bruce C V Campbell; Yan T Wong; Kate E Fox; Ewan S Nurse; Iwan E Bennett; Sébastien H Bauquier; Kishan A Liyanage; Nicole R van der Nagel; Piero Perucca; Arman Ahnood; Katherine P Gill; Bernard Yan; Leonid Churilov; Christopher R French; Patricia M Desmond; Malcolm K Horne; Lynette Kiers; Steven Prawer; Stephen M Davis; Anthony N Burkitt; Peter J Mitchell; David B Grayden; Clive N May; Terence J O'Brien
Journal:  Nat Biotechnol       Date:  2016-02-08       Impact factor: 54.908

3.  Design, fabrication and evaluation of a conforming circumpolar peripheral nerve cuff electrode for acute experimental use.

Authors:  Emily L Foldes; D Michael Ackermann; Niloy Bhadra; Kevin L Kilgore; Narendra Bhadra
Journal:  J Neurosci Methods       Date:  2010-12-25       Impact factor: 2.390

4.  Impedance characterization, degradation, and in vitro biocompatibility for platinum electrodes on BioMEMS.

Authors:  Thomas Geninatti; Giacomo Bruno; Bernardo Barile; R Lyle Hood; Marco Farina; Jeffrey Schmulen; Giancarlo Canavese; Alessandro Grattoni
Journal:  Biomed Microdevices       Date:  2015-02       Impact factor: 2.838

5.  Ultra-low Impedance Graphene Microelectrodes with High Optical Transparency for Simultaneous Deep 2-photon Imaging in Transgenic Mice.

Authors:  Yichen Lu; Xin Liu; Ryoma Hattori; Chi Ren; Xingwang Zhang; Takaki Komiyama; Duygu Kuzum
Journal:  Adv Funct Mater       Date:  2018-06-05       Impact factor: 18.808

6.  Background Signal as an in Situ Predictor of Dopamine Oxidation Potential: Improving Interpretation of Fast-Scan Cyclic Voltammetry Data.

Authors:  Carl J Meunier; James G Roberts; Gregory S McCarty; Leslie A Sombers
Journal:  ACS Chem Neurosci       Date:  2017-01-24       Impact factor: 4.418

7.  The dependence of spectral impedance on disc microelectrode radius.

Authors:  Ashish K Ahuja; Matthew R Behrend; John J Whalen; Marks S Humayun; James D Weiland
Journal:  IEEE Trans Biomed Eng       Date:  2008-04       Impact factor: 4.538

8.  Rough Gold Electrodes for Decreasing Impedance at the Electrolyte/Electrode Interface.

Authors:  Anil Koklu; Ahmet C Sabuncu; Ali Beskok
Journal:  Electrochim Acta       Date:  2016-04-14       Impact factor: 6.901

9.  Across-site patterns of electrically evoked compound action potential amplitude-growth functions in multichannel cochlear implant recipients and the effects of the interphase gap.

Authors:  Kara C Schvartz-Leyzac; Bryan E Pfingst
Journal:  Hear Res       Date:  2016-08-10       Impact factor: 3.208

10.  Form-function relations in cone-tipped stimulating microelectrodes.

Authors:  Steve Yaeli; Einat Binyamin; Shy Shoham
Journal:  Front Neuroeng       Date:  2009-08-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.