Literature DB >> 33270326

Voxel-wise partial volume correction method for accurate estimation of tissue sodium concentration in 23 Na-MRI at 7 T.

Sang-Young Kim1, Junghyun Song1, Jong-Hyun Yoon1, Kyoung-Nam Kim2, Jun-Young Chung1,3, Young Noh1,4.   

Abstract

Sodium is crucial for the maintenance of cell physiology, and its regulation of the sodium-potassium pump has implications for various neurological conditions. The distribution of sodium concentrations in tissue can be quantitatively evaluated by means of sodium MRI (23 Na-MRI). Despite its usefulness in diagnosing particular disease conditions, tissue sodium concentration (TSC) estimated from 23 Na-MRI can be strongly biased by partial volume effects (PVEs) that are induced by broad point spread functions (PSFs) as well as tissue fraction effects. In this work, we aimed to propose a robust voxel-wise partial volume correction (PVC) method for 23 Na-MRI. The method is based on a linear regression (LR) approach to correct for tissue fraction effects, but it utilizes a 3D kernel combined with a modified least trimmed square (3D-mLTS) method in order to minimize regression-induced inherent smoothing effects. We acquired 23 Na-MRI data with conventional Cartesian sampling at 7 T, and spill-over effects due to the PSF were considered prior to correcting for tissue fraction effects using 3D-mLTS. In the simulation, we found that the TSCs of gray matter (GM) and white matter (WM) were underestimated by 20% and 11% respectively without correcting tissue fraction effects, but the differences between ground truth and PVE-corrected data after the PVC using the 3D-mLTS method were only approximately 0.6% and 0.4% for GM and WM, respectively. The capability of the 3D-mLTS method was further demonstrated with in vivo 23 Na-MRI data, showing significantly lower regression errors (ie root mean squared error) as compared with conventional LR methods (p < 0.001). The results of simulation and in vivo experiments revealed that 3D-mLTS is superior for determining under- or overestimated TSCs while preserving anatomical details. This suggests that the 3D-mLTS method is well suited for the accurate determination of TSC, especially in small focal lesions associated with pathological conditions.
© 2020 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

Entities:  

Keywords:  23Na-MRI, 3D kernel; linear regression (LR); modified least trimmed square (mLTS); partial volume correction (PVC); spatial blurring; tissue sodium concentration (TSC)

Mesh:

Substances:

Year:  2020        PMID: 33270326      PMCID: PMC7816248          DOI: 10.1002/nbm.4448

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.478


  28 in total

1.  Improved partial volume correction for single inversion time arterial spin labeling data.

Authors:  Xiaoyun Liang; Alan Connelly; Fernando Calamante
Journal:  Magn Reson Med       Date:  2012-04-23       Impact factor: 4.668

2.  Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects.

Authors:  H W Müller-Gärtner; J M Links; J L Prince; R N Bryan; E McVeigh; J P Leal; C Davatzikos; J J Frost
Journal:  J Cereb Blood Flow Metab       Date:  1992-07       Impact factor: 6.200

3.  Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling.

Authors:  Jürgen Rahmer; Peter Börnert; Jan Groen; Clemens Bos
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

4.  Sodium MR imaging detection of mild Alzheimer disease: preliminary study.

Authors:  E A Mellon; D T Pilkinton; C M Clark; M A Elliott; W R Witschey; A Borthakur; R Reddy
Journal:  AJNR Am J Neuroradiol       Date:  2009-02-12       Impact factor: 3.825

Review 5.  Spectroscopic imaging: basic principles.

Authors:  Antonin Skoch; Filip Jiru; Jürgen Bunke
Journal:  Eur J Radiol       Date:  2008-04-22       Impact factor: 3.528

6.  Adaptive non-local means denoising of MR images with spatially varying noise levels.

Authors:  José V Manjón; Pierrick Coupé; Luis Martí-Bonmatí; D Louis Collins; Montserrat Robles
Journal:  J Magn Reson Imaging       Date:  2010-01       Impact factor: 4.813

Review 7.  Understanding the sodium pump and its relevance to disease.

Authors:  A M Rose; R Valdes
Journal:  Clin Chem       Date:  1994-09       Impact factor: 8.327

8.  Topography of brain sodium accumulation in progressive multiple sclerosis.

Authors:  Adil Maarouf; Bertrand Audoin; Simon Konstandin; Audrey Rico; Elisabeth Soulier; Françoise Reuter; Arnaud Le Troter; Sylviane Confort-Gouny; Patrick J Cozzone; Maxime Guye; Lothar R Schad; Jean Pelletier; Jean-Philippe Ranjeva; Wafaa Zaaraoui
Journal:  MAGMA       Date:  2013-08-03       Impact factor: 2.310

9.  Tissue sodium concentration in human brain tumors as measured with 23Na MR imaging.

Authors:  Ronald Ouwerkerk; Karen B Bleich; Joseph S Gillen; Martin G Pomper; Paul A Bottomley
Journal:  Radiology       Date:  2003-03-27       Impact factor: 11.105

10.  Distribution of brain sodium long and short relaxation times and concentrations: a multi-echo ultra-high field 23Na MRI study.

Authors:  Ben Ridley; Armin M Nagel; Mark Bydder; Adil Maarouf; Jan-Patrick Stellmann; Soraya Gherib; Jeremy Verneuil; Patrick Viout; Maxime Guye; Jean-Philippe Ranjeva; Wafaa Zaaraoui
Journal:  Sci Rep       Date:  2018-03-12       Impact factor: 4.379

View more
  1 in total

1.  Voxel-wise partial volume correction method for accurate estimation of tissue sodium concentration in 23 Na-MRI at 7 T.

Authors:  Sang-Young Kim; Junghyun Song; Jong-Hyun Yoon; Kyoung-Nam Kim; Jun-Young Chung; Young Noh
Journal:  NMR Biomed       Date:  2020-12-03       Impact factor: 4.478

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.