Abstract
BACKGROUND: Tuberculous meningitis (TBM) is a severe form of extrapulmonary tuberculosis and its early diagnosis is very difficult leading to present with severe disability or die. The current study aimed to assess the accuracy of metagenomic next generation sequencing (mNGS) for TBM, and to identify a new test for the early diagnosis of TBM.Entities:
Year: 2020 PMID: 33259541 PMCID: PMC7707562 DOI: 10.1371/journal.pone.0243161
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Flow chart of literature retrieval.
In total, 507, 53, 0, 242, and 295 articles were found in Embase, PubMed, Cochrane Library, CNKI, and Wanfang Data, respectively.
Characteristics of the included studies.
| Author | Year | County | sample type | reference | N | TP | FP | FN | TN | Type of research | Sample condition | Homogenisation | sample pre-treatment | patient selection method | patient population |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Wang S | 2019 | China | CSF | CRS | 29 | 18 | 0 | 5 | 6 | Retrospective | Frozen | Mechanical | With bead-beating | Convenience | Low |
| Zhou X | 2019 | China | CSF | CRS | 49 | 7 | 1 | 9 | 32 | Prospective | Fresh/Frozen | No | Without bead-beating | Consecutive | Low |
| Xing X | 2020 | China | CSF | CRS | 213 | 12 | 6 | 32 | 163 | Prospective | Frozen | No | With bead-beating | Convenience | Low |
| Yan L | 2020 | China | CSF | CRS | 51 | 38 | 0 | 7 | 6 | Retrospective | Fresh | Mechanical | With bead-beating | Convenience | Low |
CSF, cerebrospinal fluid; CRS, composite reference standard; TP, true-positive; FP, false-positive; FN, false-negative; TN, true-negative.
Fig 2Methodological quality graphs (risk of bias and applicability concerns) were presented as percentages across the included studies using a composite reference standard.
Fig 3Forest plot for the sensitivity and specificity of mNGS for the diagnosis of tuberculosis meningitis using a composite reference standard.
Meta-regression analysis for different parameters.
| Parameter | Sensitivity (95% CI) | Specificity (95% CI) | |
|---|---|---|---|
| Type of study | Prospective (2 studies) | 32% (20–43%) | 97% (94–99%) |
| Retrospective (2 studies) | 82% (73–91%) | 100% (100–100%) | |
| Meta-regression | <0.01 | <0.01 | |
| Homogenization | Mechanical (2 studies) | 82% (73–91%) | 100% (100–100%) |
| No (2 studies) | 32% (20–43%) | 97% (94–99%) | |
| Meta-regression | <0.01 | <0.01 | |
| Sample pre-treatment | With bead-beating (3 studies) | 66% (38–93%) | 98% (94–100%) |
| Without bead-beating (1 study) | 43% (11–98%) | 97% (91–100%) | |
| Meta-regression | 0.39 | 0.03 | |
| Patient selection | Consecutive (1 study) | 43% (11–98%) | 97% (91–100%) |
| Convenience (3 studies) | 66% (38–93%) | 98% (94–100%) | |
| Meta-regression | 0.44 | 0.21 | |
CI: confidence interval