Literature DB >> 33252844

Nasal preparation with local anesthetic should be considered an aerosol-generating procedure.

Rana S Dhillon1, Lana V Nguyen1, Wagih Abu Rowin2, Ruhi S Humphries3, Kevin Kevin2, Jason D Ward3, Andrew Yule4, Tuong D Phan5, David Wynne1, Peter M McNeill1, Nicholas Hutchins2, David A Scott5, Yi Chen Zhao6.   

Abstract

Entities:  

Keywords:  Endoscopic Endonasal Approach to the pituitary; Endoscopic Sinus Surgery; Endoscopic minimally invasive surgery of the skull base; Endoscopy

Mesh:

Substances:

Year:  2020        PMID: 33252844      PMCID: PMC7753550          DOI: 10.1002/alr.22753

Source DB:  PubMed          Journal:  Int Forum Allergy Rhinol        ISSN: 2042-6976            Impact factor:   5.426


× No keyword cloud information.
There are concerns regarding the risk of coronavirus‐2019 (COVID‐19) transmission to health‐care workers during aerosol‐ generating procedures (AGPs) in otolaryngology. Nasal preparation with local anesthetic is a valuable adjunct to many of these procedures as it is locally vasoconstrictive and provides topical anesthesia. To date, there have been no studies on aerosol generation during nasal preparation in live patients. In this study we have aimed to characterize aerosols generated during nasal preparation in intubated patients in an operating theater (OR) setting.

Patients and methods

Ethics approval and informed consent was obtained. We recruited a convenience sample of 3 patients scheduled to undergo endonasal pituitary surgery. Surgery was performed in a 126‐m3 OR under 20 Pa of positive pressure. After induction of general anesthesia, nasal preparation commenced with lidocaine hydrochloride at 5 mg/spray combined with phenylephrine hydrochloride at 500 µg/spray (CoPhenylcaine Forte Spray; ENT Technologies, Hawthorn East, Victoria, Australia), This was delivered as 4 metered sprays from a 50‐mL bottle with an atomizing nozzle via each nostril. This was followed by submucosal infiltration of the nasal septum with 1.8 mL of lidocaine hydrochloride 2% with adrenaline 1:80,000 (Lignospan Special; Septodont, Saint‐Maur‐des‐Fossés, France) using a 25G needle on a dental syringe. Each nostril was then packed with 3 CoPhenylcaine Forte‒soaked cottonoid patties for a duration of 5 minutes. Particle image velocimetry (PIV) was used to detect relatively larger particles by capturing disturbances in a laser light sheet with high‐ and low‐speed cameras. Trajectory lines and tracking algorithms were used to calculate airborne distances and durations (Fig. 1). Air sampling with time‐of‐flight spectrometry was used to detect relatively smaller particles, with an aerodynamic particle sizer (APS) and a mini wide‐range aerosol spectrometer. Background noise was evaluated with normal theater traffic to set detection limits. Statistical analysis was performed using an independent‐samples t test to compare mean values using open source SciPy version 1.5.2 (Scientific computing in Python).
FIGURE 1

Subtracted gray‐scale high‐speed image obtained during submucosal injection showing trajectory lines used to calculate particle dispersion.

Subtracted gray‐scale high‐speed image obtained during submucosal injection showing trajectory lines used to calculate particle dispersion.

Results

Nasal preparation generated significantly more aerosols than baseline concentrations (p < 0.005). Specifically, the CoPhenylcaine spray produced a 40‐fold increase above background noise (Fig. 2), with particle sizes ranging from 0.1 to 5 µm, which decreased to baseline noise levels after 180 seconds and traveled to the boundaries of the theater walls. Submucosal injection produced a 50‐ to 100‐fold increase above baseline with particle sizes >75 µm, with a total airborne duration of 3 seconds traveling a distance of 1.7 meters. Due to the larger particle sizes generated, this was not captured as signal on APS measurements but was captured on the PIV system. Nasal packing with CoPhenylcaine‐soaked patties did not produce signals above background noise.
FIGURE 2

Time‐series demonstrating number concentrations generated during nasal preparation measured by aerodynamic particle sizing (aps). Dashed lines represent background noise.

Time‐series demonstrating number concentrations generated during nasal preparation measured by aerodynamic particle sizing (aps). Dashed lines represent background noise.

Discussion

To our knowledge, nasal preparation has not been previously assessed in live patients for its ability to generate aerosols. Our data suggest that nasal preparation with local anesthetic spray and submucosal injection generates aerosols. These findings are not altogether surprising. It is likely that nasal spray generates an airflow jet that reflects off nasal walls back through the nasal aperture. Likewise, particles can be generated during submucosal injection if the bevel of the needle is not entirely submucosal, or if high enough submucosal pressures are generated that an airflow jet forces its way around the submucosal needle tip. These events are hypothesized to carry a combination of particles that are both introduced and the patient's own. The particle profile is important in understanding the risk that such events may present. Nasal spray generated small particles, which are known to remain suspended in airflows for long durations and are transported long distances by airflows within the room. On the other hand, injection generated large particles of >75 µm. These behave ballistically, remaining airborne for short durations, and traveling short distances before settling on surfaces. These findings have important clinical implications, not just in ORs but also in clinics. First, local anesthetic spray is used commonly in an outpatient clinic setting before endonasal procedures such as nasoendoscopy or nasal cautery. Our findings suggest that this step generates small particles that remain suspended for 180 seconds in the OR with 26 volume air exchanges per hour. US Centers for Disease Control and Prevention recommendations for similar rates of air exchange indicate that approximately 14 minutes is required to remove 99% of airborne contaminants. In an outpatient setting, the rate of air exchange is much lower and thus one would expect the particles to remain suspended for longer. This means that, for outpatient procedures that require nasal preparation, it is critically important to have appropriate personal protective equipment for staff. Second, nonessential staff should vacate the OR after nasal spray administration for ≥180 seconds and, during submucosal injection, should maintain a distance of ≥1.7 meters from the patient's nose. These times are likely to be longer in an outpatient setting. This study has several limitations. First, the sample size was small. Second, aerosols were not assessed as biologically active. Third, PIV requires a clean line of sight for the laser light sheet, and air sampling is a point measurement. Local anesthetic spray administration generates small particles that persist for durations dependent on the rate of room air exchange. In the OR, this duration is ≥180 seconds, but in an outpatient setting this may be longer. On the other hand, local anesthetic submucosal injection generates larger particles that travel a distance of approximately 1.7 meters. Nasal preparation should be treated as an AGP and particle‐size‒appropriate personal protective equipment should be worn.
  8 in total

1.  Characterizations of particle size distribution of the droplets exhaled by sneeze.

Authors:  Z Y Han; W G Weng; Q Y Huang
Journal:  J R Soc Interface       Date:  2013-09-11       Impact factor: 4.118

2.  Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC).

Authors:  Lynne Sehulster; Raymond Y W Chinn
Journal:  MMWR Recomm Rep       Date:  2003-06-06

Review 3.  Rhinologic Practice Special Considerations During COVID-19: Visit Planning, Personal Protective Equipment, Testing, and Environmental Controls.

Authors:  Brittany E Howard; Devyani Lal
Journal:  Otolaryngol Head Neck Surg       Date:  2020-06-02       Impact factor: 3.497

Review 4.  Assessing the safety and efficacy of drugs used in preparing the nose for diagnostic and therapeutic procedures: a systematic review.

Authors:  A M Saif; A Farboud; E Delfosse; L Pope; M Adke
Journal:  Clin Otolaryngol       Date:  2016-02-11       Impact factor: 2.597

5.  How far droplets can move in indoor environments--revisiting the Wells evaporation-falling curve.

Authors:  X Xie; Y Li; A T Y Chwang; P L Ho; W H Seto
Journal:  Indoor Air       Date:  2007-06       Impact factor: 5.770

6.  Aerosolisation during tracheal intubation and extubation in an operating theatre setting.

Authors:  R S Dhillon; W A Rowin; R S Humphries; K Kevin; J D Ward; T D Phan; L V Nguyen; D D Wynne; D A Scott
Journal:  Anaesthesia       Date:  2020-11-03       Impact factor: 6.955

Review 7.  Clinical evidence based review and recommendations of aerosol generating medical procedures in otolaryngology - head and neck surgery during the COVID-19 pandemic.

Authors:  Andrew Thamboo; Jane Lea; Doron D Sommer; Leigh Sowerby; Arman Abdalkhani; Christopher Diamond; Jennifer Ham; Austin Heffernan; M Cai Long; Jobanjit Phulka; Yu Qi Wu; Phillip Yeung; Marc Lammers
Journal:  J Otolaryngol Head Neck Surg       Date:  2020-05-06

8.  Nasal preparation with local anesthetic should be considered an aerosol-generating procedure.

Authors:  Rana S Dhillon; Lana V Nguyen; Wagih Abu Rowin; Ruhi S Humphries; Kevin Kevin; Jason D Ward; Andrew Yule; Tuong D Phan; David Wynne; Peter M McNeill; Nicholas Hutchins; David A Scott; Yi Chen Zhao
Journal:  Int Forum Allergy Rhinol       Date:  2020-12-21       Impact factor: 5.426

  8 in total
  1 in total

1.  Nasal preparation with local anesthetic should be considered an aerosol-generating procedure.

Authors:  Rana S Dhillon; Lana V Nguyen; Wagih Abu Rowin; Ruhi S Humphries; Kevin Kevin; Jason D Ward; Andrew Yule; Tuong D Phan; David Wynne; Peter M McNeill; Nicholas Hutchins; David A Scott; Yi Chen Zhao
Journal:  Int Forum Allergy Rhinol       Date:  2020-12-21       Impact factor: 5.426

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.