| Literature DB >> 33244462 |
Khursheed Ul Islam1, Jawed Iqbal1.
Abstract
A novel strain of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) disease (COVID-19) has been recently identified as an infectious disease affecting the respiratory system of humans. This disease is caused by SARS-CoV-2 that was identified in Chinese patients having severe pneumonia and flu-like symptoms. COVID-19 is a contagious disease that spreads rapidly via droplet particles arising through sneezing and coughing action of an infected person. The reports of asymptomatic carriers changed the scenario of symptom based-diagnosis in COVID-19 and intensified the need for proper diagnosis of the majority of the population to combat the rapid transmission of virus. The diagnosis of positive cases is necessary to ensure prompt care to affected people and also to curb further spread of infection in the population. Collecting samples at the right time and from the exact anatomical site is crucial for proper molecular diagnosis. After the complete genome sequence was available, China formulated RT-PCR as a primary diagnostic procedure for detecting SARS-CoV-2. Many in-house and commercial diagnostic kits have been developed or are under development that have a potential to lower the burden of diagnosis on the primary diagnostic techniques like RT-PCR. Serological based diagnosis is another broad category of testing that can detect different serum antibodies like IgG, IgM, and IgA in an infected patient. PCR-based diagnostic procedures that are commonly used for pathogen detection need sophisticated machines and assistance of a technical expert. Despite their reliable accuracy, they are not cost-effective tests, which a common man can afford, so it becomes imperative to look for other diagnostic approaches, which could be cost effective, rapid, and sensitive with consistent accuracy. To make such diagnostics available to the common man, many techniques can be exploited among, which are Point of Care (POC), also known as bed side testing, which is developing as a portable and promising tool in pathogen diagnosis. Other lateral flow assay (LFA)-based techniques like SHERLOCK, CRISPR-Cas12a (AIOD-CRISPR), and FNCAS9 editor-limited uniform detection assay (FELUDA), etc. have shown promising results in rapid detection of pathogens. Diagnosis holds a critical importance in the pandemic situation when there is no potential drug for the pathogen available in the market. This review sums up the different diagnostic approaches designed or proposed to combat the crisis of widespread diagnosis due to the sudden outbreak of a novel pathogen, SARS-CoV-2 in 2019.Entities:
Keywords: COVID-19; CRISPR-Cas12a; SHERLOCK; Severe Acute Respiratory Syndrome Coronavirus 2; diagnostics; reverse transcription-PCR
Mesh:
Substances:
Year: 2020 PMID: 33244462 PMCID: PMC7683783 DOI: 10.3389/fcimb.2020.560616
Source DB: PubMed Journal: Front Cell Infect Microbiol ISSN: 2235-2988 Impact factor: 5.293
Figure 1Figure depicts the scheme of sample collection and mentions different diagnostic approaches to detect SARS-CoV-2 infection. Nasopharyngeal swabs and serum samples are drawn from the patients which are further subjected to either nucleic acid or protein-based diagnosis depending on the need. Isolated viral RNA can be used for PCR, isothermal and CRISPR based methods whereas viral antigen and antibodies (IgG/IgM) are used for protein-based diagnosis like ELISA and point of care LFA methods.
Figure 2Figure represents schematics regarding the rapid and point of care test based on lateral flow assay (LFA) launched by various biotechnology companies and further approved by FDA to aid the COVID-19 testing. A sample well is flushed with blood/serum and buffer on the strip. Strip consists of three lines among which two are G and M detection lines representing IgG and IgM respectively and a quality control line represented as C line. If a red line appears on control, G and M or control and one among G/M, the test is said to be positive. Negative test shows only single redline on C line only. If C line is not visible the results are considered as invalid which needs to be repeated again.
FDA approved diagnostic kits or kits with an emergency approval in the market to be used for the detection of COVID-19.
| S/No | Name of testing kit | Technology used | Result time | Samples used | Authorization |
|---|---|---|---|---|---|
| 01 | InBios Smart Detect SARS-CoV-2 rRT-PCR Kit | RT-PCR | 4 h | Nasal/Nasopharyngeal swabs | EUA |
| 02 | CO-DIAGNOSTICS INC. Logix Smart Coronavirus 2019 (COVID-19) Kit | RT-PCR | Not mentioned | Respiratory tract samples/serum | EUA |
| 03 | Gnomegen COVID-19 RT-Digital PCR Detection Kit | RT-digital PCR | Not mentioned | Not mentioned | EUA |
| 04 | ScienCell SARS-CoV-2 Coronavirus Detection Kit | RT-qPCR | Not mentioned | Respiratory specimen/serum | EUA |
| 05 | Luminex ARIES SARS-CoV-2 Assay | RT-PCR | 2 h | Nasopharyngeal swabs | EUA |
| 06 | Luminex NxTAG CoV Extended Panel | RT-PCR | >2 h | Nasopharyngeal swabs | EUA |
| 07 | BD BioGX SARS-CoV-2 Reagents for the BD MAX™ System | RT-PCR | Not mentioned | Nasopharyngeal/ | EUA |
| 08 | BD SARS-CoV-2 Reagents for the BD MAX™ System | RT-PCR | Not mentioned | Nasopharyngeal/ | EUA |
| 09 | QIAGEN QIAstat-Dx Respiratory SARS-CoV-2 Panel | RT-PCR | 1 h | Nasopharyngeal swabs | EUA |
| 10 | Abbot ID NOW™ COVID-19 Assay | Point of care/isothermal | 15 min | Nasopharyngeal/ | EUA |
| 11 | BGI Genomics Real-Time Fluorescent RT-PCR Kit | Taq Man RT-PCR | 3 h | Throat swabs | EUA |
| 12 | Avellino CoV-2 Test | RT-PCR | 1 h | Nasopharyngeal/ | EUA |
| 13 | Avellino CoV-2 Test | PCR/point of care | 30 min | Throat and nasal swabs | EUA |
| 14 | BioFire Diagnostics BioFire® COVID-19 Test | Nested/Multiplexed/RT-PCR | 1 h | Throat and nasal swabs | EUA |
| 15 | Primerdesign Ltd. COVID-19 genesig Assay | RT-PCR | <1 h | Nasopharyngeal/ | EUA |
| 16 | ThermoFisher Scientific TaqPath COVID-19 Multiplex Diagnostic Solution | RT-PCR | <2 h | Nasopharyngeal/ | EUA |
| 17 | The Centers for Disease Control and Prevention (CDC) 2019-nCoV Diagnostic Panel | RT-PCR | >2 h | Upper/lower respiratory specimen | EUA |
| 18 | Cellex qSARS-CoV-2 IgG/IgM Rapid Test | LFA | 15-20 min | Blood/serum | EUA |
| 19 | TaqPath™ COVID-19 Combo Kit | RT-PCR | <1 h | Self-collected saliva | FDA |
These approved kits are for the test of SARS-CoV-2 under Emergency Use Approval (EUA) and the information is available till April 9, 2020 which is mentioned here. It includes technique by which the testing kit operates, time of result and sample collection (https://hitconsultant.net/2020/04/23/in-depth-32-fda-approved-covid-19-testing-kits/#.XrZnkUQzbIV).