Jessica V Jasien1, Massimo A Fazio2, Brian C Samuels2, James M Johnston3, J Crawford Downs2. 1. Vision Science Graduate Program, School of Optometry, The University of Alabama at Birmingham, Birmingham, AL, USA. 2. Department of Ophthalmology and Visual Sciences, School of Medicine, The University of Alabama at Birmingham, Birmingham, AL, USA. 3. Department of Neurosurgery, School of Medicine, The University of Alabama at Birmingham, Birmingham, AL, USA.
Abstract
Purpose: Recent retrospective clinical and animal studies suggest that cerebrospinal fluid pressure (CSFP) is important in glaucoma pathogenesis. Intraocular pressure (IOP) and CSFP are the driving components of translaminar pressure (TLP = IOP - CSFP), which acts across the lamina cribrosa (LC) thickness to create the translaminar pressure gradient (TLPG = TLP/LC thickness). Methods: We developed an implantable wireless telemetry system based on a small piezoelectric sensor with low temporal drift. IOP, measured in the anterior chamber, and intracranial pressure (ICP), measured in the brain parenchyma (as a surrogate for CSFP) were measured at 200 Hz in three male rhesus macaques (nonhuman primates, NHPs) on a 10% duty cycle (15 seconds of every 150-second period). Three-dimensional LC thickness was autosegmented as the mean thickness of the visible hyperreflective band in 48 radial spectral-domain optical coherence tomography b-scans centered on the optic nerve head. Results: Results indicated the rank order of IOP, ICP, TLP, and TLPG for waking, sleeping, and 24-hour periods averaged across all days. NHP 150110 had the highest IOP and ICP in all periods; however, it had the lowest TLPG in all periods due to its relatively thick LC. The other two NHPs showed similar shifts in the rank order of possible glaucoma risk factors. Conclusions: IOP is the only modifiable and readily measurable pressure-based risk factor for glaucoma. However, other potential risk factors such as ICP, TLP, and TLPG, as well as their rank-order patterns, differed compared to IOP across subjects, demonstrating that a comprehensive view of relevant risk factors is warranted. Translational Relevance: Future studies should consider including CSFP, TLP, and TLPG in addition to IOP as potential risk factors when assessing eye-specific glaucoma susceptibility. Copyright 2020 The Authors.
Purpose: Recent retrospective clinical and animal studies suggest that cerebrospinal fluid pressure (CSFP) is important in glaucoma pathogenesis. Intraocular pressure (IOP) and CSFP are the driving components of translaminar pressure (TLP = IOP - CSFP), which acts across the lamina cribrosa (LC) thickness to create the translaminar pressure gradient (TLPG = TLP/LC thickness). Methods: We developed an implantable wireless telemetry system based on a small piezoelectric sensor with low temporal drift. IOP, measured in the anterior chamber, and intracranial pressure (ICP), measured in the brain parenchyma (as a surrogate for CSFP) were measured at 200 Hz in three male rhesus macaques (nonhuman primates, NHPs) on a 10% duty cycle (15 seconds of every 150-second period). Three-dimensional LC thickness was autosegmented as the mean thickness of the visible hyperreflective band in 48 radial spectral-domain optical coherence tomography b-scans centered on the optic nerve head. Results: Results indicated the rank order of IOP, ICP, TLP, and TLPG for waking, sleeping, and 24-hour periods averaged across all days. NHP 150110 had the highest IOP and ICP in all periods; however, it had the lowest TLPG in all periods due to its relatively thick LC. The other two NHPs showed similar shifts in the rank order of possible glaucoma risk factors. Conclusions: IOP is the only modifiable and readily measurable pressure-based risk factor for glaucoma. However, other potential risk factors such as ICP, TLP, and TLPG, as well as their rank-order patterns, differed compared to IOP across subjects, demonstrating that a comprehensive view of relevant risk factors is warranted. Translational Relevance: Future studies should consider including CSFP, TLP, and TLPG in addition to IOP as potential risk factors when assessing eye-specific glaucoma susceptibility. Copyright 2020 The Authors.
Intraocular pressure (IOP) is a primary risk factor for glaucoma, and lowering IOP is the only proven treatment for the disease; however, the mechanisms of glaucomatous optic nerve injury are not fully understood. Optic nerve head (ONH) biomechanics, which are the physical manifestations of the force distribution in the tissues, are thought to be important to glaucoma pathophysiology.– However, to our knowledge, no studies to date have directly linked ONH biomechanics to disease in humanpatients or fully elucidated the pathways through which mechanical stress and strain damages the retinal ganglion cell axons as they pass through the ONH. Although there are many studies suggesting that ONH biomechanics– and remodeling– are important in glaucoma, other aspects of ocular physiology, such as vascular compromise,– metabolic deficiency,– and general neurodegeneration, likely contribute to the eye-specific risk of glaucoma development and/or progression. Although the biomechanical framework of glaucoma seemingly focuses on IOP, cerebrospinal fluid pressure (CSFP), and tissue strain, it also encompasses the vascular and cellular pathways of axonal damage. For example, blood flow is reduced in intrascleral vessels and intraocular capillaries under increased IOP and/or strain, and increased variable cyclic mechanical strain alters cell metabolism via mechanotransduction in many cell types, including vascular endothelial cells.–It has been hypothesized that CSFP is a driving factor in glaucoma, as it provides a counter-pressure to IOP, but only at the ONH.– Although IOP acts on the entire globe and affects ONH biomechanics through both laminar and scleral canal stress and strain, CSFP only acts as a retrolaminar pressure. CSFP effects are therefore limited to the ONH and contained lamina cribrosa (LC). Given this interplay of pressures acting on the ONH, it is plausible that the translaminar pressure (TLP = IOP – CSFP) is more relevant to glaucoma than either IOP or CSFP alone, although IOP and CSFP may affect the ONH differently according to some numerical simulations and experimental studies. It is also important to note that TLP is different from the translaminar pressure gradient (TLPG = TLP/laminar thickness), which is the pressure gradient acting across the thickness of the lamina cribrosa. TLPG captures additional structural information that may also prove relevant to glaucoma. Although snapshot IOP measurements can be performed noninvasively in the clinic, CSFP assessment is generally accomplished through lumbar puncture in the lateral decubitus position or measuring intracranial pressure (ICP) with an intraparenchymal sensor. As a result, little is known about either IOP or CSFP dynamics; however, continuous measurement of TLP fluctuations may provide insight into the mechanisms underlying glaucoma pathogenesis and/or progression.Recent retrospective clinical studies and animal experiments have suggested that higher CSFP (measured with a single lumbar puncture) is protective against glaucoma, and low CSFP increases glaucoma risk., Prospective studies have found that CSFP decreases with age and is lower in patients with primary open-angle glaucoma and normal-tension glaucoma compared to healthy controls or patients with ocular hypertension., However, TLP estimates in these reports are extrapolated because the CSFP and IOP measurements occurred at different time points, sometimes months apart. In addition, very little is known about TLP dynamics, as characterization of the true, 24-hour TLP exposure in individual eyes has not been possible due to the lack of accurate, continuous measurement of both IOP and CSFP in patients or large animal models of glaucoma, such as nonhuman primates (NHPs). Changes in IOP, CSFP, and TLP occur frequently and at multiple time scales; yet, it is not known if these fluctuations impact glaucoma development and/or progression.,,There are currently no science-based tools to predict the IOP and/or TLP/TLPG levels at which an individual's ONH will be damaged or what levels lead to progression when disease onset has occurred. Understanding the relationships among IOP, CSFP, TLP, and TLPG and their fluctuations will drive the clinical assessment of safe target IOP, TLP, and/or TLPG. Although IOP is easily measured and therapeutically altered, retrobulbar CSFP can only be estimated. To address this gap in knowledge, we have developed and validated a fully implantable, wireless telemetry system (TSE Systems Stellar, Chesterfield, MO) that can measure IOP and intracranial pressure at the level of the eye (a surrogate measure of CSFP) continuously in NHPs to elucidate the IOP, CSFP, TLP, and TLPG dynamics over long periods. The purpose of this preliminary study was to assess the differences in IOP, TLP, and TLPG and their rank order among NHPs to demonstrate stratification of potential glaucoma risk factors.
Methods
Animals
All animals were treated in accordance with the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research under an approved Institutional Animal Care and Use Committee protocol monitored by the University of Alabama at Birmingham. Three male rhesus macaques, 4.5 to 6.5 years old (Table 1), with no ocular abnormalities, were used in this study. All animals were kept on a 6:00 AM/6:00 PM light/dark cycle and fed daily at approximately 6:00 AM and 2:00 PM, with water available ad libitum through a continuous feed. Food and water intake were not monitored.
Table 1.
Animal Demographics
NHP
Age, y
Sex
Number of Days of IOP and ICP Telemetry Monitoring
Number of OCT Imaging Sessions
150069
4.5
Male
69
8
12.38
6.5
Male
88
3
150110
4.5
Male
281
9
Animal Demographics
Stellar IOP, ICP, and Arterial BP Telemetry System
We have developed and validated an implantable pressure telemetry system based on a small piezoelectric transducer with low temporal drift that accurately measures IOP in the anterior chamber, ICP in the parenchyma of the brain (as a surrogate for CSFP), and arterial blood pressure (BP) in the lumen of a major artery (data not shown) (Fig. 1). As previously described by our group, the IOP transducer was placed in the anterior chamber of the right eye and the ICP transducer was placed in the right frontal lobe, ∼2.5 cm from the midline of the brain at the same height as the IOP transducer when the animal is upright (Fig. 1). The telemetry system wirelessly records 200 measurements of each physiologic pressure per second on a 10% duty cycle (15 seconds of every 150-second period), 24 hours per day. An in-depth description of the surgical procedure and placement of the wireless telemetry implant and each pressure transducer has been previously described in our recent study describing the diurnal cycle of TLP.
Figure 1.
(A) TSE Systems Stellar IOP/ICP/BP total implant system. (B) Top view of the IOP transducer and integrated scleral baseplate for affixing the transducer to the sclera under Tenon's capsule and conjunctiva. (C) Side view of the IOP transducer and integrated scleral baseplate. (D) En face photograph of the piezoelectric IOP transducer in the anterior chamber. (E) Slit-lamp photograph of the intraocular placement of the piezoelectric IOP transducer in the anterior chamber relative to the cornea and iris. Reprinted with permission from Jasien et al.
(A) TSE Systems Stellar IOP/ICP/BP total implant system. (B) Top view of the IOP transducer and integrated scleral baseplate for affixing the transducer to the sclera under Tenon's capsule and conjunctiva. (C) Side view of the IOP transducer and integrated scleral baseplate. (D) En face photograph of the piezoelectric IOP transducer in the anterior chamber. (E) Slit-lamp photograph of the intraocular placement of the piezoelectric IOP transducer in the anterior chamber relative to the cornea and iris. Reprinted with permission from Jasien et al.
IOP and ICP Calibration
Anesthesia was induced using ketamine (3 mg/kg) with dexmedetomidine (50 µg/kg via intramuscular injection) and maintained using inhaled isoflurane (1%–3%) for ONH imaging and transducer calibrations. Proparacaine hydrochloride (0.5% ophthalmic solution) was applied to anesthetize the cornea prior to anterior chamber cannulation. During all calibration procedures, the NHPs were kept warm with a warming blanket and systemically monitored for heart rate, oxygen saturation, end-tidal CO2 volume, electrocardiogram, and temperature, with documentation every 15 minutes.As previously described, the IOP telemetry transducer was calibrated every 2 weeks via anterior chamber cannulation manometry with a 27-gauge needle placed through the cornea at the limbus under slit-lamp biomicroscopy. To assess the error in the IOP transducer reading, absolute manometric IOP is elevated from 5 to 30 mm Hg in 5-mm Hg steps. All IOP data are corrected for signal drift between calibrations using the 15-mm Hg value; transducer drift is approximately 2 mm Hg a month.The ICP telemetry transducer was calibrated once a month in the same session as the biweekly IOP telemetry transducer calibration. As previously described, a clinical gold-standard Codman ICP Express microsensor (DePuy Synthes Companies, Raynham, MA) was inserted through an indwelling custom titanium port in the cranium that allows access to the left brain parenchyma (Fig. 2). ICP was then measured by both the indwelling Stellar telemetry transducer and the Codman microsensor simultaneously at various body positions. The prone position was used as the calibration reference for all calibration sessions (Fig. 3). ICP transducer drift was similar to IOP transducer drift at approximately 2 mm Hg per month, and calibrated TLP was continuously quantified as IOP – ICP. All IOP and ICP data were recorded with NOTOCORD-hem data acquisition software (Instem, Staffordshire, UK), and all pressure data were drift-corrected continuously between calibration procedures via software postprocessing assuming linear drift between calibrations.
Figure 2.
(A) Oblique x-ray of an NHP with the Stellar implant (IOP and ICP transducers) and custom indwelling titanium ICP calibration port installed. The IOP transducer is in the right eye, and the ICP transducer is in the right lobe of the brain, whereas the calibration port is in the left lobe. The IOP and ICP transducers and bottom of the screw post within the calibration port are at the same height when the animal's head is in the upright position. (B) Photograph of the custom indwelling titanium ICP calibration port, showing the bolt with central screw. Note that the screw is sealed to the bolt with a sterile medical-grade silicone washer when installed. Reprinted with permission from Jasien et al.
Figure 3.
Screenshot of the pressure telemetry signals acquired during a typical ICP transducer calibration procedure wherein the NHP is moved from the prone position to a positive 45° incline (head up) to a negative 45° decline (head down) and back to prone. Arterial BP (blue), IOP in the right eye (red), ICP from Stellar Telemetry (green), and ICP from the Codman microsensor (gold) are recorded at 200 Hz during the calibration procedure. The y-axis scale is mm Hg for all signals. Reprinted with permission from Jasien et al.
(A) Oblique x-ray of an NHP with the Stellar implant (IOP and ICP transducers) and custom indwelling titanium ICP calibration port installed. The IOP transducer is in the right eye, and the ICP transducer is in the right lobe of the brain, whereas the calibration port is in the left lobe. The IOP and ICP transducers and bottom of the screw post within the calibration port are at the same height when the animal's head is in the upright position. (B) Photograph of the custom indwelling titanium ICP calibration port, showing the bolt with central screw. Note that the screw is sealed to the bolt with a sterile medical-grade silicone washer when installed. Reprinted with permission from Jasien et al.Screenshot of the pressure telemetry signals acquired during a typical ICP transducer calibration procedure wherein the NHP is moved from the prone position to a positive 45° incline (head up) to a negative 45° decline (head down) and back to prone. Arterial BP (blue), IOP in the right eye (red), ICP from Stellar Telemetry (green), and ICP from the Codman microsensor (gold) are recorded at 200 Hz during the calibration procedure. The y-axis scale is mm Hg for all signals. Reprinted with permission from Jasien et al.
In Vivo Imaging and Quantification of LC Thickness
Spectral-domain optical coherence tomography (SD-OCT; Spectralis 2, Heidelberg Engineering, Heidelberg, Germany) images through the ONH of each NHP were obtained monthly for the duration of the study, resulting in three to nine imaging sessions per animal. In each imaging session, 48 radial, high-resolution b-scans centered in the ONH were acquired in follow-up mode for each eye at an IOP of 10 mm Hg. IOP was set to 10 mm Hg by anterior chamber manometry and allowed to stabilize for 10 minutes prior to imaging.Automated image processing of the OCT scans was used to reduce noise, enhance contrast, and automatically segment the LC. The LC was defined as the hyperreflective band of tissue visible in each radial OCT scan. The automated segmentation algorithm operates by searching in the center of the scan volume for a continuous set of voxels with high light-intensity values. It then grows the targeted region by iteratively minimizing a three-dimensional (3D) functional form of the light intensity that is a weighted sum of the contour length, the enclosed area, and the deviation between the image and the two-level segmentation. This is a particularly effective approach in NHPs because their thinner prelaminar tissues allow for much deeper penetration of the OCT scanning beam in the ONH region. A sharp decrease in reflectivity is typically present 100 to 200 µm below the anterior LC surface, which is segmented as the posterior LC surface (Fig. 4). LC thickness was calculated as the average distance between the anterior and posterior 3D LC surfaces. Two-dimensional projections of the anterior and posterior surfaces were overlaid on each b-scan and then manually reviewed. An overlaid view of the segmentation for the nasal–temporal SD-OCT b-scan of all nine 48 radial scans taken at 10 mm Hg IOP from NHP 150069 is provided in Figure 5; similar figures are provided in the Supplementary Material for all scans at 10 mm Hg IOP for all NHPs (Supplementary Figs. S1–S3).
Figure 4.
(a) Unprocessed SD-OCT reflectance radial b-scan through the ONH in a NHP. (b) The original scan after custom filtering and deep tissue enhancement. (c) The original scan after principal light intensity curvature computation to enhance the different layers of the tissue; the hyperreflective band defining the LC is clearly visible, and LC autosegmentation is shown in Figure 5.
Figure 5.
Lamina cribrosa thickness (µm) in the nasal–temporal b-scans through the ONH in all eight sessions, 1 month apart, for NHP 150069 at an IOP of 10 mm Hg.
(a) Unprocessed SD-OCT reflectance radial b-scan through the ONH in a NHP. (b) The original scan after custom filtering and deep tissue enhancement. (c) The original scan after principal light intensity curvature computation to enhance the different layers of the tissue; the hyperreflective band defining the LC is clearly visible, and LC autosegmentation is shown in Figure 5.Lamina cribrosa thickness (µm) in the nasal–temporal b-scans through the ONH in all eight sessions, 1 month apart, for NHP 150069 at an IOP of 10 mm Hg.
Statistical Analysis
One-way analyses of variance were used to determine if IOP, ICP, TLP, and TLPG were different across NHPs within each time period (wake, sleep, and 24-hour) and to determine the difference in LC thickness across NHPs. In order to test the reproducibility of quantifying LC thickness by autosegmentation, we assessed the intra- and intersubject variability of the LC thickness across imaging sessions (4 weeks apart). F-test significance was computed as the LC thickness variance between animals divided by the variance across imaging sessions (error term).
Results
Translaminar Pressure Gradient
The rank order of IOP, ICP, TLP, and TLPG for the waking, sleeping, and 24-hour periods averaged across all days is shown in Table 2. Although NHP 150110 has the highest IOP and ICP in all periods, it had the lowest TLPG in all periods due to its relatively thick LC. Similar shifts in the rank order of possible glaucoma risk factors were also observed for the other two NHPs. Also, note the relatively small standard deviations, showing low variability and excellent repeatability in all measures. IOP, ICP, TLP, and TLPG were significantly different among the NHPs in the wake, sleep, and 24-hour periods (P < 0.0001), except for the TLP 24-hour period (P = 0.7).
Table 2.
Average IOP, ICP, TLP, and TLPG for the Waking (6:00–18:00), Sleeping (18:00–6:00), and 24-Hour Periods Across All Days by NHP, Presented in Color-Coded Rank Order
Average IOP, ICP, TLP, and TLPG for the Waking (6:00–18:00), Sleeping (18:00–6:00), and 24-Hour Periods Across All Days by NHP, Presented in Color-Coded Rank OrderRank order: green, lowest; yellow, middle; red, highest.
Repeatability of the LC Thickness Autosegmentation
Descriptive statistics of LC thickness variation across animals and IOP are summarized by means and standard deviations in Table 2. Intra- and intersubject variability quantification showed that, across animals, variation of LC thickness (thickness of the hyperreflective band) was significantly larger (NHPs, F-ratio = 96.46) than its variability across imaging sessions (P < 0.001) (Table 3).
Table 3.
F-Ratio Values for LC Thickness Variability Across NHPs and Imaging Sessions
Variable
Mean Square
F-Ratio
P
NHPs
37,815.98
96.46
<0.001
Imaging session
392.04
1.00
0.50
Error
586.74
1.50
0.21
Total
2515.68
6.42
0.00
F-Ratio Values for LC Thickness Variability Across NHPs and Imaging Sessions
Discussion
In this preliminary study, IOP and ICP data were collected in three male rhesus macaques on a 10% duty cycle, consisting of 200 measurements per second captured for 15 seconds of every 150-second period over a range of 69 to 281 days. TLPG measurements were calculated as (IOP – ICP)/LC thickness, defined as the overall mean thickness of the hyperreflective band within 48 radial SD-OCT image sets taken through the center of the ONH. Outcomes from the F-ratio analyses show that the hyperreflective band thickness in OCT was repeatable and therefore adequate for detecting the eye-specific variability in LC thickness. We have focused on eye-specific responses to IOP and TLP/TLPG that could contribute to glaucomatous pathophysiology. The purpose of this study was to assess the differences in IOP, TLP, and TLPG and their rank order among NHPs to demonstrate stratification of potential glaucoma risk factors. Results show that other potential risk factors such as ICP/CSFP, TLP, and TLPG, as well as their rank-order patterns, differ compared to IOP across subjects, demonstrating that a comprehensive view of relevant risk factors is warranted.There is a strong and consistent diurnal cycle in ICP and TLP in NHPs, wherein TLP is much higher during waking hours in four NHPs, and this pattern matches that reported for humans. Importantly, the diurnal cycle of TLP is driven primarily by CSFP, not IOP, due to the large magnitude of diurnal CSFP changes, further indicating that CSFP plays an important role in ONH biomechanics and may contribute to glaucoma. As mentioned, TLPG takes laminar morphology into account and may be even more relevant to glaucoma than IOP, CSFP, or TLP. Morgan and colleagues, measured TLPG in dogs and found a strong correlation between the TLPG and TLP when the ICP was greater than 0 mm Hg. Hou and colleagues also showed a positive correlation between ICP and retrolaminar tissue pressure above 3 mm Hg in dogs, although retrolaminar pressure was constant when ICP was less than 3 mm Hg. These studies showed that ICP and retrolaminar pressure are generally similar in dogs; therefore, it is reasonable to use ICP as a surrogate for CSFP when quantifying TLP in NHPs, as done in this study. We have recently shown that both ICP and TLP exhibit a large nychthemeral rhythm in spite of the fact that NHPs sleep sitting up, with TLP showing a 4.2-mm Hg (56%) mean increase during waking hours compared to sleeping hours. A similar relative increase in ICP has been reported in humans when moving from the upright to supine position. Unlike humans, NHPs sleep upright, so the large diurnal cycle in ICP and TLP was somewhat unexpected; the source of this nocturnal ICP increase is still being investigated in our laboratory.The most striking finding in the current study is that the rank order of TLPG in these NHPs, which takes the laminar structure into account and may be even more relevant to glaucoma than IOP, CSFP, or TLP, is completely different from the order of these potential risk factors. Ample evidence suggests that higher IOP increases glaucoma risk. If one presumes that higher TLP and/or higher TLPG also increases glaucoma risk, then stratifying the three NHPs in this study by potential risk using a single variable is problematic, as shown in Table 2. In fact, the NHP with the highest IOP is also the animal with the lowest TLPG, demonstrating that a more comprehensive view of the possible glaucoma risk factors is warranted. Further study of the contributions of IOP, TLP, and TLPG to glaucoma risk are needed.The study is limited by the following considerations. First, the study was limited to a small sample size of three NHPs due to the preliminary nature of the investigation; hence, the reported results may not translate to the larger population of Rhesus macaques, although the results were significantly different among animals across time periods and thus we had adequate statistical power to detect effects. Future studies should be sure to include a larger sample size. Also, these results may not translate to the human population, although similar differences in LC thickness have been reported among patients,, so it is likely that similar variability in TLPG would be present across patients. Second, the repeatability of the number of scans was a closer confidence interval in the animals with more OCT sessions. The repeatability of the segmentation of the LC thickness measurements as the hyperreflective band has to be validated with a larger study and the use of histological measurements, as it is known that posterior identification of the LC using OCT is challenging.IOP is the only modifiable and readily measurable pressure-based risk factor for glaucoma, but other potential risk factors such as ICP, TLP, and TLPG may differ compared to IOP across subjects, demonstrating that a comprehensive view of relevant risk factors is warranted. Future studies should consider including CSFP, TLP, and TLPG in addition to IOP as potential risk factors when assessing eye-specific glaucoma susceptibility.
Authors: Michael D Roberts; Vicente Grau; Jonathan Grimm; Juan Reynaud; Anthony J Bellezza; Claude F Burgoyne; J Crawford Downs Journal: Invest Ophthalmol Vis Sci Date: 2008-09-20 Impact factor: 4.799
Authors: Katy C Liu; David Fleischman; Andrew G Lee; Hanspeter E Killer; John J Chen; M Tariq Bhatti Journal: Surv Ophthalmol Date: 2019-08-23 Impact factor: 6.048