Technical evaluation of image quality in synthetic mammograms obtained from 15° and 40° digital breast tomosynthesis in a commercial system: a quantitative comparison.

Patrizio Barca1, Rocco Lamastra2,3, Raffaele Maria Tucciariello2,3, Antonio Traino4, Carolina Marini5, Giacomo Aringhieri6, Davide Caramella6, Maria Evelina Fantacci2,3.   

Abstract

Digital breast tomosynthesis (DBT) has recently gained interest both for breast cancer screening and diagnosis. Its employment has increased also in conjunction with digital mammography (DM), to improve cancer detection and reduce false positive recall rate. Synthetic mammograms (SMs) reconstructed from DBT data have been introduced to replace DM in the DBT + DM approach, for preserving the benefits of the dual-acquisition modality whilst reducing radiation dose and compression time. Therefore, different DBT models have been commercialized and the effective potential of each system has been investigated. In particular, wide-angle DBT was shown to provide better depth resolution than narrow-angle DBT, while narrow-angle DBT allows better identification of microcalcifications compared to wide-angle DBT. Given the increasing employment of SMs as supplement to DBT, a comparison of image quality between SMs obtained in narrow-angle and wide-angle DBT is of practical interest. Therefore, the aim of this phantom study was to evaluate and compare the image quality of SMs reconstructed from 15° (SM15) and 40° (SM40) DBT in a commercial system. Spatial resolution, noise and contrast properties were evaluated through the modulation transfer function (MTF), noise power spectrum, maps of signal-to-noise ratio (SNR), image contrast, contrast-to-noise ratio (CNR) and contrast-detail (CD) thresholds. SM40 expressed higher MTF than SM15, but also lower SNR and CNR levels. SM15 and SM40 were characterized by slight different texture, and a different behavior in terms of contrast was found. SM15 provided better CD performances than SM40. These results suggest that the employment of wide/narrow-angle DBT + SM images should be optimized based on the specific image task.

Entities:  

Keywords:  Digital breast tomosynthesis; Image quality; Mammography; S-view; Synthetic mammogram; Wide angle DBT

Year:  2020        PMID: 33226534     DOI: 10.1007/s13246-020-00948-2

Source DB:  PubMed          Journal:  Phys Eng Sci Med        ISSN: 2662-4729


  42 in total

1.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

2.  Breast-cancer screening--viewpoint of the IARC Working Group.

Authors:  Béatrice Lauby-Secretan; Chiara Scoccianti; Dana Loomis; Lamia Benbrahim-Tallaa; Véronique Bouvard; Franca Bianchini; Kurt Straif
Journal:  N Engl J Med       Date:  2015-06-03       Impact factor: 91.245

Review 3.  Advances in Digital Breast Tomosynthesis.

Authors:  Regina J Hooley; Melissa A Durand; Liane E Philpotts
Journal:  AJR Am J Roentgenol       Date:  2016-10-27       Impact factor: 3.959

Review 4.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

Review 5.  A review of breast tomosynthesis. Part I. The image acquisition process.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

6.  Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial.

Authors:  Per Skaane; Andriy I Bandos; Loren T Niklason; Sofie Sebuødegård; Bjørn H Østerås; Randi Gullien; David Gur; Solveig Hofvind
Journal:  Radiology       Date:  2019-02-19       Impact factor: 11.105

7.  Digital Mammography versus Digital Mammography Plus Tomosynthesis for Breast Cancer Screening: The Reggio Emilia Tomosynthesis Randomized Trial.

Authors:  Pierpaolo Pattacini; Andrea Nitrosi; Paolo Giorgi Rossi; Valentina Iotti; Vladimiro Ginocchi; Sara Ravaioli; Rita Vacondio; Luca Braglia; Silvio Cavuto; Cinzia Campari
Journal:  Radiology       Date:  2018-06-05       Impact factor: 11.105

8.  Diagnostic Efficacy of Synthesized 2D Digital Breast Tomosynthesis in Multi-ethnic Malaysian Population.

Authors:  N Ab Mumin; K Rahmat; F Fadzli; M T Ramli; C J Westerhout; N Ramli; F I Rozalli; K H Ng
Journal:  Sci Rep       Date:  2019-02-06       Impact factor: 4.379

9.  GPU acceleration of a model-based iterative method for Digital Breast Tomosynthesis.

Authors:  R Cavicchioli; J Cheng Hu; E Loli Piccolomini; E Morotti; L Zanni
Journal:  Sci Rep       Date:  2020-01-08       Impact factor: 4.379

10.  Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial.

Authors:  Aldo Badano; Christian G Graff; Andreu Badal; Diksha Sharma; Rongping Zeng; Frank W Samuelson; Stephen J Glick; Kyle J Myers
Journal:  JAMA Netw Open       Date:  2018-11-02