| Literature DB >> 33206760 |
Maria Clara Motta Barbosa Valente1, Aline Tenório Lins Carnaúba2, Janise Dal Pai3, Kelly Cristina Lira de Andrade2, Pedro de Lemos Menezes2.
Abstract
OBJECTIVE: To determine the central tendency measures and variability of vestibular evoked myogenic potential (VEMP) with regard to the latency and wave amplitude when potentials are captured from the flexor muscles of the forearm.Entities:
Mesh:
Year: 2020 PMID: 33206760 PMCID: PMC7603288 DOI: 10.6061/clinics/2020/e2020
Source DB: PubMed Journal: Clinics (Sao Paulo) ISSN: 1807-5932 Impact factor: 2.365
Figure 1Positioning of electrodes on the forearm.
Figure 2VEMP grand average of the right and left forearms.
Figure 3Grand average resulting from all VEMP examinations captured on the forearm, with emphasis on the P34 positive peak and the N44 negative peak.
Latencies, interpeak intervals, and resulting average amplitudes, standard deviations, and normal ranges for VEMP of the forearm.
| Wave component | Average (ms) | Standard deviation | Inferior normal limit (CI 95% IL-SL) | Superior normal limit (CI 95% IL-SL) |
|---|---|---|---|---|
| P34 latency | 34.9 | 2.6 | 29.3 (27.7-30.9) | 40.4 (38.8-42.1) |
| N44 latency | 43.6 | 2.1 | 39.1 (37.7-40.4) | 48.1 (46.7-49.4) |
| N44-P34 interval | 8.7 | 1.5 | 5.4 (4.5-6.4) | 11.9 (10.9-12.8) |
| P34 amplitude | 43.3 | 20.8 | - | - |
| N44 amplitude | -36.9 | 30.0 | - | - |
Note: The limits of normality for amplitudes were not calculated since the asymmetry index was used for this measurement.
Average amplitudes, standard deviation, and asymmetry index between the ears for the forearm VEMP.
| Wave component | Average (ms) | Standard deviation | % Average asymmetry index (SD) |
|---|---|---|---|
| P34 amplitude (R) | 38.0 | 16.4 | 15.4 (±10.7) |
| N44 amplitude (R) | -33.8 | 18.6 | |
| P34 amplitude (L) | 48.6 | 25.1 | |
| N44 amplitude (L) | -40.0 | 40.7 |
R: Right side, L: Left Side.