Outcome of transcatheter aortic valve replacement in bicuspid aortic valve stenosis with new-generation devices.

Riccardo Gorla1, Matteo Casenghi1, Alice Finotello2, Federico De Marco1, Simone Morganti3, Damiano Regazzoli4, Giovanni Bianchi1, Elena Acerbi1, Antonio Popolo Rubbio1, Nedy Brambilla1, Luca Testa1, Fausto Castriota5, Ferdinando Auricchio6, Bernhard Reimers4, Francesco Bedogni1.   

Abstract

OBJECTIVES: To compare device success and paravalvular leak rates of 3 new-generation transcatheter aortic valve replacement devices in patients with bicuspid aortic valve stenosis and to test their biomechanical performance in a computer-based simulation model of aortic root with increasing ellipticity.
METHODS: This retrospective multicentre study included 56 bicuspid aortic valve patients undergoing transcatheter aortic valve replacement with new-generation devices: Lotus/Lotus Edge (N = 15; 27%), Evolut-R (N = 20; 36%) and ACURATE neo (N = 21; 37%). Three virtual simulation models of aortic root with increasing index of eccentricity (0-0.25-0.5) were implemented. Stress distribution, stent-root contact area and paravalvular orifice area were computed.
RESULTS: Device success was achieved in 43/56 patients (77%) with comparable rates among Lotus (87%), Evolut-R (60%) and ACURATE neo (86%; P = 0.085). Moderate paravalvular leak rate was significantly lower in the Lotus group as compared to Evolut-R group (0% vs 30%; P = 0.027) and comparable to the ACURATE neo group (0% vs 10%; P = 0.33). By index of eccentricity = 0.5, Lotus showed a uniform and symmetric pattern of stress distribution with absent paravalvular orifice area, ACURATE neo showed a mild asymmetry with small paravalvular orifice area (1.1 mm2), whereas a severely asymmetric pattern was evident with Evolut-R, resulting in a large paravalvular orifice area (12.0 mm2).
CONCLUSIONS: Transcatheter aortic valve replacement in bicuspid aortic valve patients with new-generation devices showed comparable device success rates. Lotus showed moderate paravalvular leak rate comparable to that of ACURATE neo and significantly lower than Evolut-R. On simulation, Lotus and ACURATE neo showed optimal adaptability to elliptic anatomies as compared to Evolut-R.
© The Author(s) 2020. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Bicuspid aortic valve; Computational simulation; New-generation devices; Transcatheter aortic valve replacement

Mesh:

Year:  2021        PMID: 33201993      PMCID: PMC8906794          DOI: 10.1093/icvts/ivaa231

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  26 in total

1.  Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI).

Authors:  S Tzamtzis; J Viquerat; J Yap; M J Mullen; G Burriesci
Journal:  Med Eng Phys       Date:  2012-05-27       Impact factor: 2.242

2.  Optimal Implantation Depth and Adherence to Guidelines on Permanent Pacing to Improve the Results of Transcatheter Aortic Valve Replacement With the Medtronic CoreValve System: The CoreValve Prospective, International, Post-Market ADVANCE-II Study.

Authors:  Anna S Petronio; Jan-Malte Sinning; Nicolas Van Mieghem; Giulio Zucchelli; Georg Nickenig; Raffi Bekeredjian; Johan Bosmans; Francesco Bedogni; Marian Branny; Karl Stangl; Jan Kovac; Molly Schiltgen; Stacia Kraus; Peter de Jaegere
Journal:  JACC Cardiovasc Interv       Date:  2015-05       Impact factor: 11.195

3.  Transcatheter aortic valve implantation using the ACURATE neo in bicuspid and tricuspid aortic valve stenosis: a propensity-matched analysis of a European experience.

Authors:  Antonio Mangieri; Alaide Chieffo; Won-Keun Kim; Giulio G Stefanini; Giuseppe Rescigno; Marco Barbanti; Corrado Tamburino; Andreas Rück; Matteo Pagnesi; Rickard Linder; Stefan Toggweiler; Matteo Montorfano; Antonio Colombo
Journal:  EuroIntervention       Date:  2018-12-20       Impact factor: 6.534

4.  Bicuspid Aortic Valve Anatomy and Relationship With Devices: The BAVARD Multicenter Registry.

Authors:  Didier Tchetche; Chiara de Biase; Lennart van Gils; Radoslaw Parma; Andrzej Ochala; Thierry Lefevre; Thomas Hovasse; Ole De Backer; Lars Sondergaard; Sabine Bleiziffer; Rudiger Lange; Ran Kornowski; Uri Landes; Bjarne Linde Norgaard; Luigi Biasco; Raphaël Philippart; Javier Molina-Martin de Nicolas; Darren Mylotte; Caroline Lemee; Nicolas Dumonteil; Nicolas M Van Mieghem
Journal:  Circ Cardiovasc Interv       Date:  2019-01       Impact factor: 6.546

5.  Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients.

Authors:  Michael J Mack; Martin B Leon; Vinod H Thourani; Raj Makkar; Susheel K Kodali; Mark Russo; Samir R Kapadia; S Chris Malaisrie; David J Cohen; Philippe Pibarot; Jonathon Leipsic; Rebecca T Hahn; Philipp Blanke; Mathew R Williams; James M McCabe; David L Brown; Vasilis Babaliaros; Scott Goldman; Wilson Y Szeto; Philippe Genereux; Ashish Pershad; Stuart J Pocock; Maria C Alu; John G Webb; Craig R Smith
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

6.  Performance of the Evolut-R 34 mm versus Sapien-3 29 mm in Transcatheter aortic valve replacement patients with larger annuli: Early outcome results of Evolut-R 34 mm as compared with Sapien-3 29 mm in patients with Annuli ≥26 mm.

Authors:  Amnon Eitan; Julian Witt; Jan Stripling; Timo Haselbach; Friedrich-Christian Rieß; Joachim Schofer
Journal:  Catheter Cardiovasc Interv       Date:  2018-03-09       Impact factor: 2.692

7.  Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis.

Authors:  Sung-Han Yoon; Sabine Bleiziffer; Ole De Backer; Victoria Delgado; Takahide Arai; Johannes Ziegelmueller; Marco Barbanti; Rahul Sharma; Gidon Y Perlman; Omar K Khalique; Erik W Holy; Smriti Saraf; Florian Deuschl; Buntaro Fujita; Philipp Ruile; Franz-Josef Neumann; Gregor Pache; Masao Takahashi; Hidehiro Kaneko; Tobias Schmidt; Yohei Ohno; Niklas Schofer; William K F Kong; Edgar Tay; Daisuke Sugiyama; Hiroyuki Kawamori; Yoshio Maeno; Yigal Abramowitz; Tarun Chakravarty; Mamoo Nakamura; Shingo Kuwata; Gerald Yong; Hsien-Li Kao; Michael Lee; Hyo-Soo Kim; Thomas Modine; S Chiu Wong; Francesco Bedgoni; Luca Testa; Emmanuel Teiger; Christian Butter; Stephan M Ensminger; Ulrich Schaefer; Danny Dvir; Philipp Blanke; Jonathon Leipsic; Fabian Nietlispach; Mohamed Abdel-Wahab; Bernard Chevalier; Corrado Tamburino; David Hildick-Smith; Brian K Whisenant; Seung-Jung Park; Antonio Colombo; Azeem Latib; Susheel K Kodali; Jeroen J Bax; Lars Søndergaard; John G Webb; Thierry Lefèvre; Martin B Leon; Raj Makkar
Journal:  J Am Coll Cardiol       Date:  2017-03-18       Impact factor: 24.094

Review 8.  Transcatheter aortic valve implantation in bicuspid aortic valve stenosis.

Authors:  Gidon Y Perlman; Philipp Blanke; John G Webb
Journal:  EuroIntervention       Date:  2016-09-18       Impact factor: 6.534

9.  Transcatheter aortic valve replacement in bicuspid aortic valve disease.

Authors:  Darren Mylotte; Thierry Lefevre; Lars Søndergaard; Yusuke Watanabe; Thomas Modine; Danny Dvir; Johan Bosmans; Didier Tchetche; Ran Kornowski; Jan-Malte Sinning; Pascal Thériault-Lauzier; Crochan J O'Sullivan; Marco Barbanti; Nicolas Debry; Jean Buithieu; Pablo Codner; Magdalena Dorfmeister; Giuseppe Martucci; Georg Nickenig; Peter Wenaweser; Corrado Tamburino; Eberhard Grube; John G Webb; Stephan Windecker; Ruediger Lange; Nicolo Piazza
Journal:  J Am Coll Cardiol       Date:  2014-12-01       Impact factor: 24.094

10.  Simulation of transcatheter aortic valve implantation through patient-specific finite element analysis: two clinical cases.

Authors:  S Morganti; M Conti; M Aiello; A Valentini; A Mazzola; A Reali; F Auricchio
Journal:  J Biomech       Date:  2014-06-20       Impact factor: 2.712

View more
  2 in total

1.  Procedural and clinical outcomes of transcatheter aortic valve replacement in bicuspid aortic valve patients: a systematic review and meta-analysis.

Authors:  Cheng-Hao Jacky Chen; Henry Jiang; Owen Martin; Ashley R Wilson-Smith
Journal:  Ann Cardiothorac Surg       Date:  2022-07

2.  Safety and Efficacy of Myval Implantation in Patients with Severe Bicuspid Aortic Valve Stenosis-A Multicenter Real-World Experience.

Authors:  Ahmed Elkoumy; John Jose; Christian J Terkelsen; Henrik Nissen; Sengottuvelu Gunasekaran; Mahmoud Abdelshafy; Ashok Seth; Hesham Elzomor; Sreenivas Kumar; Francesco Bedogni; Alfonso Ielasi; Santosh K Dora; Sharad Chandra; Keyur Parikh; Daniel Unic; William Wijns; Andreas Baumbach; Darren Mylotte; Patrick Serruys; Osama Soliman
Journal:  J Clin Med       Date:  2022-01-15       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.