Literature DB >> 22640661

Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI).

S Tzamtzis1, J Viquerat, J Yap, M J Mullen, G Burriesci.   

Abstract

A better understanding of the mechanisms producing the radial force in transcatheter heart valves is essential in order to reduce the reported cases of migration and atrio-ventricular block and improve the effectiveness of the treatment. This paper presents a numerical study of the different mechanisms responsible for the radial force exerted on the aortic annulus by self-expanding and balloon-expandable prostheses. The behavior of the Medtronic CoreValve (self-expanding) and the Edwards SAPIEN (balloon-expandable) devices, both of size 26, has been simulated and compared. The results indicate that, for both prostheses, the radial force may vary considerably within the recommended functional range for the valve implantation and is substantially higher at the smallest annular sizes. In particular, in the case of the self-expanding valve the radial force is essentially dependent on the diameter of the left ventricular outflow tract, while for the balloon-expandable valve the radial force produced is influenced by both the geometry and stiffness of the host tissue. The outcomes of this study provide a better insight into the phenomenon and useful information that could support the development of improved solutions.
Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22640661     DOI: 10.1016/j.medengphy.2012.04.009

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  30 in total

1.  In Vitro and Ex Vivo Hemodynamic Testing of an Innovative Occluder for Paravalvular Leak After Transcather Aortic Valve Implantation.

Authors:  Paolo Peruzzo; Gaetano Burriesci; Francesca Maria Susin; Andrea Colli
Journal:  J Cardiovasc Transl Res       Date:  2019-07-30       Impact factor: 4.132

Review 2.  Pacemaker implantation after transcatheter aortic valve: why is this still happening?

Authors:  Stefan Toggweiler; Richard Kobza
Journal:  J Thorac Dis       Date:  2018-11       Impact factor: 2.895

Review 3.  Clinical significance of conduction disturbances after aortic valve intervention: current evidence.

Authors:  Manuel Martinez-Selles; Peter Bramlage; Martin Thoenes; Gerhard Schymik
Journal:  Clin Res Cardiol       Date:  2014-07-04       Impact factor: 5.460

Review 4.  Transcatheter aortic valve implantation-induced left bundle branch block: causes and consequences.

Authors:  Thomas T Poels; Patrick Houthuizen; Leen A F M Van Garsse; Jos G Maessen; Peter de Jaegere; Frits W Prinzen
Journal:  J Cardiovasc Transl Res       Date:  2014-05-07       Impact factor: 4.132

5.  Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre.

Authors:  Dayimi Kaya; Zulkif Tanriverdi; Huseyin Dursun; Tugce Colluoglu
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-09       Impact factor: 2.357

Review 6.  Permanent pacemaker insertion in patients with conduction abnormalities post transcatheter aortic valve replacement: a review and proposed guidelines.

Authors:  Tamunoinemi Bob-Manuel; Amit Nanda; Samuel Latham; Issa Pour-Ghaz; William Paul Skelton; Rami N Khouzam
Journal:  Ann Transl Med       Date:  2018-01

7.  Quantification of biomechanical interaction of transcatheter aortic valve stent deployed in porcine and ovine hearts.

Authors:  Joseph Mummert; Eric Sirois; Wei Sun
Journal:  Ann Biomed Eng       Date:  2012-11-17       Impact factor: 3.934

8.  Numerical Parametric Study of Paravalvular Leak Following a Transcatheter Aortic Valve Deployment Into a Patient-Specific Aortic Root.

Authors:  Wenbin Mao; Qian Wang; Susheel Kodali; Wei Sun
Journal:  J Biomech Eng       Date:  2018-10-01       Impact factor: 2.097

9.  Short-term pacemaker dependency after transcatheter aortic valve implantation.

Authors:  Christiana Schernthaner; Johannes Kraus; Franz Danmayr; Matthias Hammerer; Jens Schneider; Uta C Hoppe; Bernhard Strohmer
Journal:  Wien Klin Wochenschr       Date:  2016-01-08       Impact factor: 1.704

10.  Simulations of transcatheter aortic valve implantation: implications for aortic root rupture.

Authors:  Qian Wang; Susheel Kodali; Charles Primiano; Wei Sun
Journal:  Biomech Model Mechanobiol       Date:  2014-04-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.