Literature DB >> 3320091

Comparison of conventional and revised isolator blood culture tubes.

B A Basille1, K A Easley, G S Hall, J A Washington.   

Abstract

A paired clinical study compared bacterial and fungal recovery from 4,553 blood cultures processed by the conventional Isolator (Du Pont Co.) and a revised Isolator consisting of a single-stoppered, round-bottom tube containing the same ingredients as the conventional tube except for an inert fluorochemical. Excluding contaminants, there were 425 positive blood cultures with 450 isolates representing 208 patients. There were no statistically significant differences between systems in the number of positive cultures or patients with positive cultures for each organism group studied, nor were there any statistically significant differences between systems in the time required for detection of positive cultures.

Entities:  

Mesh:

Year:  1987        PMID: 3320091      PMCID: PMC269448          DOI: 10.1128/jcm.25.11.2221-2222.1987

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Mycobacterium tuberculosis bacteremia detected by the Isolator lysis-centrifugation blood culture system.

Authors:  T E Kiehn; J W Gold; P Brannon; R J Timberger; D Armstrong
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

2.  Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from blood.

Authors:  J Bille; L Stockman; G D Roberts; C D Horstmeier; D M Ilstrup
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

3.  Clinical evaluation of a lysis-centrifugation technique for the detection of septicemia.

Authors:  M T Kelly; M F Fojtasek; T M Abbott; D C Hale; J R Dizikes; R Boshard; G E Buck; W J Martin; J M Matsen
Journal:  JAMA       Date:  1983-10-28       Impact factor: 56.272

4.  Microbiological and clinical evaluation of the isolator lysis-centrifugation blood culture tube.

Authors:  N K Henry; C A McLimans; A J Wright; R L Thompson; W R Wilson; J A Washington
Journal:  J Clin Microbiol       Date:  1983-05       Impact factor: 5.948

  4 in total
  2 in total

1.  Conventional and revised isolator tubes.

Authors:  J A Washington; A Philip
Journal:  J Clin Microbiol       Date:  1988-01       Impact factor: 5.948

2.  Comparison of the lysis-centrifugation and agitated biphasic blood culture systems for detection of fungemia.

Authors:  P R Murray
Journal:  J Clin Microbiol       Date:  1991-01       Impact factor: 5.948

  2 in total