Literature DB >> 33194106

Assessment of Bone Quality Using Radiogrammetric Parameters of Proximal Humerus in India: Defining the Osteoporotic Fracture Risk Limit Value and its Reliability.

Sonali Jain1, Sumit Arora2, Swati Gupta3, Siddharth Sharma2, Nitish Bansal2, Shashi Ranjan2.   

Abstract

BACKGROUND: World health organization (WHO) has defined osteoporosis clinically on the basis of bone mineral density (BMD) measurement by dual-energy X-ray absorptiometry (DXA) scan and the presence of fractures. This facility is expensive and not readily available in majority of the centers in India. The authors have attempted to study defined measurements on radiographs (radiogrammetric parameters) to diagnose osteoporosis in Indian population. PATIENTS AND METHODS: We prospectively studied 200 proximal humerus radiographs for measuring radiogrammetric parameters and divided into Group A and B (N = 100 in each group). Group A involved patients with age < 50 years and without any illness affecting bone quality. Group B involved patients with age > 50 years and sustained acute osteoporotic fractures of distal radius/ anterior wedge vertebral fracture/intertrochanteric fracture following trivial trauma. Three parameters (cortical thickness, cortical index and deltoid tuberosity index) were measured by 3 observers at 2 different occasions.
RESULTS: The mean age of patients was 37.87 years and 58.38 years for group A and B, respectively. The 'cortical thickness' of the proximal humerus diaphysis had the mean value for Group A and B to be 0.4 ± 0.07 cm and 0.33 ± 0.06 cm respectively. The mean values for the 'cortical index' of proximal humerus came out to be 0.4 ± 0.07 for group A and 0.32 ± 0.06 for group B. The 'deltoid tuberosity index' measurements showed the mean values for group A and B were 1.81 ± 0.23 and 1.55 ± 0.16, respectively. Inter-observer reliability for single measures was excellent for deltoid tuberosity index (ICC 0.8077) and good for cortical thickness (ICC 0.7032) and cortical index (ICC 0.7357). Observer 1 had excellent intra-observer reliabilities for all the three parameters. Observer 2 and 3 had excellent reliability for deltoid tuberosity index and good intra-observer reliability for cortical thickness and cortical index. The cortical thickness had a cut off of ≤ 0.372 cm with a sensitivity of 86.02 and specificity of 82.12. The cortical index had a cut off of ≤ 0.378 with a sensitivity of 89.16 and specificity of 84.22. The deltoid tuberosity index had a cut off of ≤ 1.684 with a sensitivity of 96.61 and specificity of 84.08.
CONCLUSION: The outcome of this study is likely to help in early diagnosis of osteoporosis at the community level in the absence of DXA scan as it identifies threshold values for radiogrammetric parameters which can be a predictor of the osteoporosis. The deltoid tuberosity index was found to be the most suitable of these parameters. © Indian Orthopaedics Association 2020.

Entities:  

Year:  2020        PMID: 33194106      PMCID: PMC7609647          DOI: 10.1007/s43465-020-00224-1

Source DB:  PubMed          Journal:  Indian J Orthop        ISSN: 0019-5413            Impact factor:   1.251


  12 in total

1.  Bone health in healthy Indian population aged 50 years and above.

Authors:  R K Marwaha; N Tandon; M K Garg; R Kanwar; A Narang; A Sastry; A Saberwal; K Bhadra; A Mithal
Journal:  Osteoporos Int       Date:  2011-01-27       Impact factor: 4.507

2.  The cortical thickness of the proximal humeral diaphysis predicts bone mineral density of the proximal humerus.

Authors:  Markus J Tingart; Maria Apreleva; Dietrich von Stechow; David Zurakowski; Jon J Warner
Journal:  J Bone Joint Surg Br       Date:  2003-05

Review 3.  Epidemiology of osteoporosis and osteoporotic fractures.

Authors:  S R Cummings; J L Kelsey; M C Nevitt; K J O'Dowd
Journal:  Epidemiol Rev       Date:  1985       Impact factor: 6.222

4.  The diagnosis of osteoporosis.

Authors:  J A Kanis; L J Melton; C Christiansen; C C Johnston; N Khaltaev
Journal:  J Bone Miner Res       Date:  1994-08       Impact factor: 6.741

5.  Osteoporosis in Asia: a call to action.

Authors:  Ambrish Mithal; Parjeet Kaur
Journal:  Curr Osteoporos Rep       Date:  2012-12       Impact factor: 5.096

6.  Bone quality measured by the radiogrammetric parameter "cortical index" and reoperations after locking plate osteosynthesis in patients sustaining proximal humerus fractures.

Authors:  Pierre Hepp; Jan Theopold; Georg Osterhoff; Bastian Marquass; Christine Voigt; Christoph Josten
Journal:  Arch Orthop Trauma Surg       Date:  2009-05-14       Impact factor: 3.067

Review 7.  DXA scanning in clinical practice.

Authors:  A El Maghraoui; C Roux
Journal:  QJM       Date:  2008-03-10

8.  Age- and gender-related distribution of bone tissue of osteoporotic humeral head using computed tomography.

Authors:  Mitsuko Yamada; Jêrome Briot; Annaig Pedrono; Nicolas Sans; Pierre Mansat; Michel Mansat; Pascal Swider
Journal:  J Shoulder Elbow Surg       Date:  2007-07-23       Impact factor: 3.019

9.  Proximal humerus cortical bone thickness correlates with bone mineral density and can clinically rule out osteoporosis.

Authors:  James Mather; Joy C MacDermid; Kenneth J Faber; George S Athwal
Journal:  J Shoulder Elbow Surg       Date:  2012-11-22       Impact factor: 3.019

Review 10.  Calcaneal quantitative ultrasound as a determinant of bone health status: what properties of bone does it reflect?

Authors:  Kok-Yong Chin; Soelaiman Ima-Nirwana
Journal:  Int J Med Sci       Date:  2013-10-25       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.