Literature DB >> 33169104

Submillisievert chest CT in patients with COVID-19 - experiences of a German Level-I center.

Christina M Hamper1, Florian Nima Fleckenstein1,2, Laura Büttner1, Bernd Hamm1, Nadine Thieme1, Hans-Martin Thiess1, Oriane Scholz1, Felix Döllinger1, Georg Böning1.   

Abstract

PURPOSE: Computed tomography (CT) is used for initial diagnosis and therapy monitoring of patients with coronavirus disease 2019 (COVID-19). As patients of all ages are affected, radiation dose is a concern. While follow-up CT examinations lead to high cumulative radiation doses, the ALARA principle states that the applied dose should be as low as possible while maintaining adequate image quality. The aim of this study was to evaluate parameter settings for two commonly used CT scanners to ensure sufficient image quality/diagnostic confidence at a submillisievert dose.
MATERIALS AND METHODS: We retrospectively analyzed 36 proven COVID-19 cases examined on two different scanners. Image quality was evaluated objectively as signal-to-noise ratio (SNR)/contrast-to-noise ratio (CNR) measurement and subjectively by two experienced, independent readers using 3-point Likert scales. CT dose index volume (CTDIvol) and dose-length product (DLP) were extracted from dose reports, and effective dose was calculated.
RESULTS: With the tested parameter settings we achieved effective doses below 1 mSv (median 0.5 mSv, IQR: 0.2 mSv, range: 0.3-0.9 mSv) in all 36 patients. Thirty-four patients had typical COVID-19 findings. Both readers were confident regarding the typical COVID-19 CT-characteristics in all cases (3 ± 0). Objective image quality parameters were: SNRnormal lung: 17.0 ± 5.9, CNRGGO/normal lung: 7.5 ± 5.0, and CNRconsolidation/normal lung: 15.3 ± 6.1.
CONCLUSION: With the tested parameters, we achieved applied doses in the submillisievert range, on two different CT scanners without sacrificing diagnostic confidence regarding COVID-19 findings.
© 2020 The Author(s).

Entities:  

Keywords:  COVID-19; Coronavirus; Dose reduction; German Level-I center; Low-dose chest CT; SARS-CoV2

Year:  2020        PMID: 33169104      PMCID: PMC7609045          DOI: 10.1016/j.ejro.2020.100283

Source DB:  PubMed          Journal:  Eur J Radiol Open        ISSN: 2352-0477


Introduction

The new coronavirus (SARS-CoV-2) and the disease it causes (COVID-19) were first reported in the city of Wuhan, China, in December 2019 [1,2]. In most cases, SARS-CoV-2 manifests with only mild symptoms, but some patients develop a severe disease, which can lead to acute respiratory distress syndrome (ARDS), multiple organ failure, and death [3,4]. There are specific pulmonary findings associated with COVID-19 in chest computed tomography (CT), including bilateral ground-glass opacities (GGO) with peripheral distribution, consolidations, and the “crazy-paving” pattern or “reverse halo” sign [[5], [6], [7], [8], [9], [10], [11], [12], [13]]. In the course of the disease, CT can show these typical changes, even if no virus is detected in the nasopharyngeal or throat swab [14,15]. Reverse transcription polymerase chain reaction (RT-PCR) testing is limited by a longer waiting time for results. Therefore, CT imaging can speed up diagnosis of COVID-19 and provide valuable findings in the further course of disease [16]. Kang et al. even recommended low-dose CTs for initial diagnosis and to monitor the course of COVID-19 [14]. They underline that a CT can be very helpful early at the onset of symptoms or when the swab test is negative [14,15]. Esposito et al. also conclude that chest CT is a good and fast imaging modality for first-line triage of patients with suspected COVID-19 [17]. Radpour et al. focus on the advantages of low-dose CT especially in regions with many patients and limited availability of RT-PCR tests [18]. Nevertheless, the results should be interpreted with caution, as they depend on the disease status, testing method, and imaging technique (e.g., applied dose). As all age groups are affected by COVID-19 according to a multi-center study of Yang et al., which was also summarized in an article of Yi et al. [19], the potential risks arising from the radiation dose associated with CT need to be addressed [14] as findings like GGO are sometimes not visible in chest radiographs [20]. Nevertheless, the diagnostic confidence of chest CT must be guaranteed regarding typical pulmonary findings associated with COVID-19. The aim of this study was therefore, based on experiences of a German center, to evaluate parameter settings for two commonly used CT scanners that potentially ensure sufficient image quality/diagnostic confidence regarding COVID-19 findings at submillisievert dose levels.

Materials and methods

Study design/patient cohort

This retrospective study was approved by the Local Ethics Committee of our hospital (EA4/074/20). Based on published data and our experience, we selected acquisition parameters for low-dose chest scans in patients with suspected COVID-19 (see Table 1) examined on two scanners from different vendors. We retrospectively included 36 patients from two sites (n = 17/19) of our German Level-I university center, who were treated between March 30 and April 22, 2020. All patients included were positive for SARS-CoV-2 (RT-PCR of nasopharyngeal and oropharyngeal swab samples; patients with a negative RT-PCR test result were excluded (Fig. 1)). Maximum axial and sagittal body diameters of patients` chest CTs were measured to assess body size.
Table 1

Detailed technical parameters of the two CT scanners investigated: The parameters were chosen on the basis of published experience and experience at our center.

GE Light-Speed VCTCanon Aquilion Prime
Voltage100 kVp100 kVp
Tube current20−120 mA10−120 mA
Noise parameterNI: 40SD: 27
Rotation time0.4 s0.35 s
Pitch1.3751.388
Recon IR levelASIR 50AIDR 3D standard
Collimation64 × 0.625 mm80 × 0.5 mm
ATCMonon
Recon modeslice (axial)volume 1/0.8
Recon section interval0.625 mm1 mm
Field of viewDFOV: depending on patient sizeSFOV: 50 cmDFOV: depending on patient sizeSFOV: 50 cm
Fig. 1

Patient cohort.

We retrospectively enrolled 36 patients from two sites (n = 17/19) of our central European Level-I university center. All patients included were positive for SARS-CoV-2 (RT-PCR of nasopharyngeal and oropharyngeal swab samples); patients with a negative RT-PCR test result were excluded.

Detailed technical parameters of the two CT scanners investigated: The parameters were chosen on the basis of published experience and experience at our center. Patient cohort. We retrospectively enrolled 36 patients from two sites (n = 17/19) of our central European Level-I university center. All patients included were positive for SARS-CoV-2 (RT-PCR of nasopharyngeal and oropharyngeal swab samples); patients with a negative RT-PCR test result were excluded.

Technical CT parameters

We established chest CT examinations with new low-dose protocols immediately when the first cases of COVID-19 appeared. Parameters for the protocols were selected on the basis of published data and our center’s experience with clinical CT protocols (Table 1) [14,[21], [22], [23], [24]]. At each site of our center, all patients who were positive for SARS-CoV-2 or highly suspected of having COVID-19 were examined on a CT scanner equipped with these low-dose-protocols (Table 1).

Subjective image quality

Two experienced radiologists with 5 and 10 years of expertise in the evaluation of chest CTs independently read the scans and scored image quality/diagnostic confidence regarding the presence of typical pulmonary COVID-19 CT findings (peripheral GGO, consolidations, etc.) on a 3-point Likert scale (1-no diagnosis possible, 2-limited diagnostic confidence, 3-full diagnostic confidence).

Objective image quality

For objective image quality analysis, two experienced readers in consensus manually placed circular regions of interest (ROIs) in normal lung, surrounding air, and, if present, GGO and consolidation while carefully avoiding interfering structures such as larger blood vessels or airways. Example positions of ROIs are shown in Fig. 2.
Fig. 2

Example cases of six patients with typical findings of COVID-19 in low-dose-chest CT.

a): 75-year-old woman with peripheral GGO, ED 0.5 mSv

b): 78-year-old man with peripheral GGO, ED 0.4 mSv

c): 71-year-old man with peripheral GGO, ED 0.4 mSv

d): 62-year-old man with mixed GGO and reticular pattern, ED 0.4 mSv

e): 67-year-old man with peripheral GGO and consolidations, ED 0.4 mSv

The red circles in E show the positions of ROIs for measurement of objective image quality

f): 51-year-old man with peripheral GGO, ED 0.4 mSv.

Example cases of six patients with typical findings of COVID-19 in low-dose-chest CT. a): 75-year-old woman with peripheral GGO, ED 0.5 mSv b): 78-year-old man with peripheral GGO, ED 0.4 mSv c): 71-year-old man with peripheral GGO, ED 0.4 mSv d): 62-year-old man with mixed GGO and reticular pattern, ED 0.4 mSv e): 67-year-old man with peripheral GGO and consolidations, ED 0.4 mSv The red circles in E show the positions of ROIs for measurement of objective image quality f): 51-year-old man with peripheral GGO, ED 0.4 mSv. We calculated ROI-based signal-to-noise ratio (SNR) of normal lung and contrast-to-noise ratios (CNRs) of GGO to normal lung and consolidations to normal lung. SNR was defined as: CNRGGO to lung as: CNRconsolidation to lung as: Measurements were done in lung kernel reconstructions of 0.625 mm (GE Lightspeed VCT) or 1 mm (Canon Aquilion Prime) slice thickness, according to our clinical standards.

Applied dose

Effective dose (ED) was estimated with CT-Expo 2.5® software (Dr. rer. nat. Georg Stamm, Medizinische Hochschule Hannover, Hannover, Germany) based on the CTDIvol and DLP extracted from the dose reports. It was in line with calculations by multiplying the dose-length-product (DLP) by 0.0144 mSv/mGy cm as the conversion factor for thoracic imaging according to ICRP (International Commission on Radiological Protection) 103 [25].

Statistical analysis

Calculations and graphs were created with GraphPad Prism v. 5 ® (GraphPad Software, San Diego, CA, USA). Based on parameter scale and the outcome of the Shapiro-Wilk test for normal distribution, results are given as mean and standard deviation (SD) or median and interquartile range (IQR).

Results

Patient cohort

The study population consisted of a total of 36 patients (men: n = 27 (75 %), women: n = 9 (25 %)) with a mean age of 59.2 ± 15.4 years (range: 24–90 years) (Fig. 3). Thirty-four of 36 patients (94 %) had findings typical for COVID-19 in CT imaging.
Fig. 3

a) Age and b) body diameter distribution in the patient population.

Mean patient age was 59.2 years; mean diameters were 24.7 cm and 24.6 cm in a sagittal and axial orientation, respectively.

a) Age and b) body diameter distribution in the patient population. Mean patient age was 59.2 years; mean diameters were 24.7 cm and 24.6 cm in a sagittal and axial orientation, respectively. Maximum patient diameters were 24.7 ± 3.2 mm and 24.6 ± 3.3 mm (sagittal and axial orientation) (Fig. 3). Thirty-four of 36 patients had typical findings of COVID-19 including peripheral GGO, consolidations, and/or crazy paving; however, all 36 CT studies were rated for diagnostic confidence. The two independent raters scored all scans as completely confident (3 ± 0). Calculated SNR/CNR values for the assessment of objective image quality were in line with expectations based on our earlier experience and are consistent with subjective scoring. For all cases taken together, we obtained the following ratios: SNRlung: 17.0 ± 5.9, CNRGGO to lung: 7.5 ± 5.0, and CNRconsolidation to lung: 15.3 ± 6.1. For further deails see Fig. 4.
Fig. 4

a-c: CNRs for a) pulmonary GGO, b) consolidations and c) SNR for total lung.

The mean SNRlung was 17.0, the mean CNRGGO to lung: 7.5 and the mean CNRconsolidation to lung: 15.3

a-c: CNRs for a) pulmonary GGO, b) consolidations and c) SNR for total lung. The mean SNRlung was 17.0, the mean CNRGGO to lung: 7.5 and the mean CNRconsolidation to lung: 15.3 CTDIvol was 0.9 ± 0.3 mGy, retrospectively resulting in a DLP of 35 ± 10.2 mGy*cm and a median ED of 0.5 mSv (IQR: 0.2 mSv, range: 0.3−0.9 mSv) (Fig. 5). Mean ED was 0.5 ± 0.2 mSv (Fig. 5).
Fig. 5

a-c: Applied doses as a) CTDI, b) DLP and c) ED.

Mean CTDIvol was 0.9 mGy, mean DLP 35 mGy*cm, and mean ED 0.5 mSv.

CTIDvol: volume computed tomography dose index, DLP: dose length product, ED: effective dose

a-c: Applied doses as a) CTDI, b) DLP and c) ED. Mean CTDIvol was 0.9 mGy, mean DLP 35 mGy*cm, and mean ED 0.5 mSv. CTIDvol: volume computed tomography dose index, DLP: dose length product, ED: effective dose

Discussion

As CT is frequently used in patients with COVID-19 the risks associated with radiation exposure should be taken into account, especially in younger patients [14]. Following the ALARA principle, a low-dose approach to CT scanning is necessary without sacrificing the diagnostic confidence. The aim of our study was therefore to identify CT parameter settings that fulfil these requirements. The sex distribution of COVID-19 patients in our study - 75 % men and 25 % women - fits to results in literature [26]. In the study of Huang et al., 73 % of patients with COVID-19 were male, whereas in the study of Itelman et al., 65 % of the affected patients were male [4,27]. The mean age of our patients was 59.2 ± 15.4 years (range 24–90 years), which is consistent with the results of other studies such as that of Yang et al., who showed that COVID-19 affects all age groups. In their multicenter study on 8.866 patients, including 4.021 confirmed COVID-19 patients, nearly half of the patients (47.7 %) were older than 50 years, Yi et al. reported [19]. Itelman et al. found a mean age of 52 ± 20 years in 162 patients in Israel [27]. In our study, 94 % of the patients (34/36) with positive RT-PCR testing had typical pulmonary CT findings associated with COVID-19. Pan et al. analyzed typical findings in patients with COVID-19 over time from initial diagnosis to recovery. They concluded that pulmonary manifestations were most severe 10 days after the first symptoms [28]. Of note, four patients did not have typical findings in their initial chest CT but later on [28]. Kanne et al. also show that up to around 50 % of patients with COVID-19 do not have abnormal CT scans in the first two days after onset of symptoms [29]. Thus, the two negative CT scans in our study may be attributable to an early stage of the disease. In our study the readers consistently assigned the highest diagnostic confidence to all scans. Dangis et al. also investigated subjective evaluation of CT images and concluded, that submillisievert chest CT allows for assessment of COVID-19 in patients at the emergency room (ER) [21]. In our study, we additionally determined CNR and SNR for objective image quality assessment, and the results underline our subjective impression. SNRlung was 17.0 ± 5.9, CNRGGO to lung 7.5 ± 5.0, and CNRconsolidation to lung 15.3 ± 6.1. Comparable to our results, Agostini et al. found a median SNRlung of 12.2 (range 9.83–14.21) [22]. Kang et al. reported an SNR of 0.47 and CNR of 1.09 for their low-dose protocol but did not give details on calculation [14]. In each of our 36 patients, ED was lower than 1 mSv with a median of 0.5 mSv (IQR: 0.2mSv, range: 0.3−0.9 mSv) and a mean ED of 0.5 ± 0.2 mSv. Kang et al. compared two adult patients with COVID-19 of similar height, body size, and age examined in a Siemens scanner. One was examined with a low-dose CT protocol, the other with a standard-dose protocol. ED in the low-dose-protocol was 0.203 mSv whereas, in our study of 36 patients, the lowest ED was 0.3 mSv. Furthermore, Kang et al. only examined two patients and did not report details of patients’ age, height, and body size [14]. Agostini et al. examined ten patients with COVID-19 using a standard-dose and a low-dose protocol. Median ED was 0.28 mSv (range 0.25−0.42 mSv) with their low-dose protocol at 100 kVp on a Siemens scanner [22]. Dangis et al. achieved a mean ED of 0.58 ± 0.25 mSv in chest CT examinations with a low-dose protocol of 83 patients with COVID-19, which is comparable to our results [21]. Our mean CTDIvol was 0.9 ± 0.3 mGy, which is higher than that of 0.39 mGy reported by Kang et al. [14]. The median CTDIvol in the study of Agostini et al. was also lower at 0.64 mGy (range 0.47–1.12 mGy) [22]. Dangis et al. had a higher mean CTDIvol of 1.33 ± 0.55 mGy in a group of 83 patients with COVID-19 [21]. Our mean DLP was 35 ± 10.2 mGy*cm, which is again above that of Kang et al. [14], which was 14.5 mGy*cm, and the median DLP reported by Agostini et al. was also lower at 19.5 mGy*cm (17.5–29.02 mGy*cm) [22]. Our median DLP was lower than that of 41.4 ± 17.7 mGy*cm reported by Dangis et al. in a group of 83 patients with COVID-19 [21]. In sum, published results for ED, CTDIvol and DLP are comparable to our results and thus appear to be robust for a mid-European patient collective. Differences may be due to variations in patient size or other technical parameter settings (e.g. iterative reconstruction level). Of course, if CT is not performed for COVID-19 diagnosis alone and there are additional questions to be answered (e.g., pulmonary embolism), administration of contrast medium and use of higher dose settings could be necessary. The main limitation of our study is the small sample size of 36 patients and the retrospective, single-center design. Furthermore, we only evaluated two CT scanners, and the readers were not blinded to technical parameters or the diagnosis. We only included patients > 18 years and did not compare low-dose with normal-dose chest CT. In addition, the results probably cannot be transferred to patients with larger body diameters and dedicated studies should be performed. In conclusion, the presented parameter settings allow acquisition of chest CT scans with dose exposure in the submillisievert range on the two CT scanners used in our study without sacrificing diagnostic confidence regarding the presence of typical pulmonary changes associated with COVID-19.

Credit author statement

CMH and GB analyzed and interpreted the data and were responsible for the manuscript writing. GB was the major contributor of the conceptualization of the study. BH was the major contributor to the administration. GB, FD, NT and OS supported the project’s administration. HMT, LB, FNF, OS, FD and NT supported the conceptualization of this study and the manuscript writing.

Ethical statement

This retrospective study was approved by the Local Ethics Committee of our hospital (EA4/074/20).

Funding

We acknowledge support from the German Research Foundation (DFG) and the Open Access Publication Funds of Charité – Universitätsmedizin Berlin.

Declaration of Competing Interest

The authors declare no conflict of interest.
  22 in total

Review 1.  Radiation dose reduction techniques for chest CT: Principles and clinical results.

Authors:  Yoshiharu Ohno; Hisanobu Koyama; Shinichiro Seki; Yuji Kishida; Takeshi Yoshikawa
Journal:  Eur J Radiol       Date:  2018-12-20       Impact factor: 3.528

2.  Clinical Characterization of 162 COVID-19 patients in Israel: Preliminary Report from a Large Tertiary Center.

Authors:  Edward Itelman; Yishay Wasserstrum; Amitai Segev; Chen Avaky; Liat Negru; Dor Cohen; Natia Turpashvili; Sapir Anani; Eyal Zilber; Nir Lasman; Ahlam Athamna; Omer Segal; Tom Halevy; Yehuda Sabiner; Yair Donin; Lital Abraham; Elisheva Berdugo; Adi Zarka; Dahlia Greidinger; Muhamad Agbaria; Noor Kitany; Eldad Katorza; Gilat Shenhav-Saltzman; Gad Segal
Journal:  Isr Med Assoc J       Date:  2020-05       Impact factor: 0.892

3.  Essentials for Radiologists on COVID-19: An Update-Radiology Scientific Expert Panel.

Authors:  Jeffrey P Kanne; Brent P Little; Jonathan H Chung; Brett M Elicker; Loren H Ketai
Journal:  Radiology       Date:  2020-02-27       Impact factor: 11.105

4.  Time Course of Lung Changes at Chest CT during Recovery from Coronavirus Disease 2019 (COVID-19).

Authors:  Feng Pan; Tianhe Ye; Peng Sun; Shan Gui; Bo Liang; Lingli Li; Dandan Zheng; Jiazheng Wang; Richard L Hesketh; Lian Yang; Chuansheng Zheng
Journal:  Radiology       Date:  2020-02-13       Impact factor: 11.105

5.  Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China.

Authors:  Chaolin Huang; Yeming Wang; Xingwang Li; Lili Ren; Jianping Zhao; Yi Hu; Li Zhang; Guohui Fan; Jiuyang Xu; Xiaoying Gu; Zhenshun Cheng; Ting Yu; Jiaan Xia; Yuan Wei; Wenjuan Wu; Xuelei Xie; Wen Yin; Hui Li; Min Liu; Yan Xiao; Hong Gao; Li Guo; Jungang Xie; Guangfa Wang; Rongmeng Jiang; Zhancheng Gao; Qi Jin; Jianwei Wang; Bin Cao
Journal:  Lancet       Date:  2020-01-24       Impact factor: 79.321

6.  Clinical Characteristics of Coronavirus Disease 2019 in China.

Authors:  Wei-Jie Guan; Zheng-Yi Ni; Yu Hu; Wen-Hua Liang; Chun-Quan Ou; Jian-Xing He; Lei Liu; Hong Shan; Chun-Liang Lei; David S C Hui; Bin Du; Lan-Juan Li; Guang Zeng; Kwok-Yung Yuen; Ru-Chong Chen; Chun-Li Tang; Tao Wang; Ping-Yan Chen; Jie Xiang; Shi-Yue Li; Jin-Lin Wang; Zi-Jing Liang; Yi-Xiang Peng; Li Wei; Yong Liu; Ya-Hua Hu; Peng Peng; Jian-Ming Wang; Ji-Yang Liu; Zhong Chen; Gang Li; Zhi-Jian Zheng; Shao-Qin Qiu; Jie Luo; Chang-Jiang Ye; Shao-Yong Zhu; Nan-Shan Zhong
Journal:  N Engl J Med       Date:  2020-02-28       Impact factor: 91.245

7.  A Novel Coronavirus from Patients with Pneumonia in China, 2019.

Authors:  Na Zhu; Dingyu Zhang; Wenling Wang; Xingwang Li; Bo Yang; Jingdong Song; Xiang Zhao; Baoying Huang; Weifeng Shi; Roujian Lu; Peihua Niu; Faxian Zhan; Xuejun Ma; Dayan Wang; Wenbo Xu; Guizhen Wu; George F Gao; Wenjie Tan
Journal:  N Engl J Med       Date:  2020-01-24       Impact factor: 91.245

8.  COVID-19 Evaluation by Low-Dose High Resolution CT Scans Protocol.

Authors:  Alireza Radpour; Hooman Bahrami-Motlagh; Mohammad Taghi Taaghi; Abdolrasul Sedaghat; Mohammad Ali Karimi; Ali Hekmatnia; Hamid-Reza Haghighatkhah; Morteza Sanei-Taheri; Mehran Arab-Ahmadi; Arash Azhideh
Journal:  Acad Radiol       Date:  2020-04-17       Impact factor: 3.173

9.  COVID-19 pneumonia manifestations at the admission on chest ultrasound, radiographs, and CT: single-center study and comprehensive radiologic literature review.

Authors:  Pascal Lomoro; Francesco Verde; Filippo Zerboni; Igino Simonetti; Claudia Borghi; Camilla Fachinetti; Anna Natalizi; Alberto Martegani
Journal:  Eur J Radiol Open       Date:  2020-04-04

10.  Proposal of a low-dose, long-pitch, dual-source chest CT protocol on third-generation dual-source CT using a tin filter for spectral shaping at 100 kVp for CoronaVirus Disease 2019 (COVID-19) patients: a feasibility study.

Authors:  Andrea Agostini; Chiara Floridi; Alessandra Borgheresi; Myriam Badaloni; Paolo Esposto Pirani; Filippo Terilli; Letizia Ottaviani; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2020-04-01       Impact factor: 6.313

View more
  4 in total

1.  Diagnostic Value of Initial Chest CT Findings for the Need of ICU Treatment/Intubation in Patients with COVID-19.

Authors:  Laura Büttner; Annette Aigner; Florian Nima Fleckenstein; Christina Maria Hamper; Martin Jonczyk; Bernd Hamm; Oriane Scholz; Georg Böning
Journal:  Diagnostics (Basel)       Date:  2020-11-10

2.  Do submillisievert-chest CT protocols impact diagnostic quality in suspected COVID-19 patients?

Authors:  Hans-Martin Thieß; Keno K Bressem; Lisa Adams; Georg Böning; Janis L Vahldiek; Stefan M Niehues
Journal:  Acta Radiol Open       Date:  2022-01-19

3.  A novel Gray-Scale spatial exploitation learning Net for COVID-19 by crawling Internet resources.

Authors:  Mohamed E ElAraby; Omar M Elzeki; Mahmoud Y Shams; Amena Mahmoud; Hanaa Salem
Journal:  Biomed Signal Process Control       Date:  2021-12-05       Impact factor: 3.880

4.  CHEST CT USAGE IN COVID-19 PNEUMONIA: MULTICENTER STUDY ON RADIATION DOSES AND DIAGNOSTIC QUALITY IN BRAZIL.

Authors:  Monica Bernardo; Fatemeh Homayounieh; Maria Cristina Rodel Cuter; Luiz Mário Bellegard; Homero Medeiros Oliveira Junior; Gabriela Oliveira Buril; Juliana Santana de Melo Tapajós; Danilo Moulin Sales; Luiz Claudio de Moura Carvalho; Débora Alves Pinto; Ricardo Varella; Luciano Leitão Tapajós; Shadi Ebrahimian; Jenia Vassileva; Mannudeep K Kalra; Helen Jamil Khoury
Journal:  Radiat Prot Dosimetry       Date:  2021-12-30       Impact factor: 0.972

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.