Literature DB >> 33145701

Digital Variance Angiography in Lower-Limb Angiography with Metal Implants.

M B Bastian1, A M König1, S Viniol1, M Gyánó2,3, D Szöllősi4,3, I Góg5,3, J P Kiss3, S Osvath4,3, K Szigeti4,3, A H Mahnken1, R P Thomas6.   

Abstract

PURPOSE: The presence of metal implants may reduce angiographic image quality due to automated beam adjustments. Digital variance angiography (DVA) is reported to be superior to digital subtraction angiography (DSA) with increased contrast-to-noise ratio (CNR) and better image quality. The aim of the study was to evaluate whether DVA could counterbalance the image quality impairment of lower-limb angiographies with metal implants.
MATERIALS AND METHODS: From November 2019 to January 2020, 85 raw lower-limb iodine contrast angiograms of 12 patients with metal implants were processed retrospectively with DVA analyses. For objective comparison, CNR of DSA and DVA images was calculated and the ratio CNRDVA/CNRDSA was determined. Visual image quality was evaluated in a paired comparison and by a five-grade Likert scale by three experienced radiologists.
RESULTS: The CNR was calculated and compared in 1252 regions of interest in 37 image pairs containing metal implants. The median ratio of CNRDVA/CNRDSA was 1.84 with an interquartile range of 1.35-2.32. Paired comparison resulted in 84.5% in favour of DVA with an interrater agreement of 83.2% (Fleiss κ 0.454, p < 0.001). The overall image quality scores for DSA and DVA were 3.64 ± 0.08 and 4.43 ± 0.06, respectively (p < 0.001, Wilcoxon signed-rank test) with consistently higher individual ratings for DVA.
CONCLUSION: Our small-sample pilot study shows that DVA provides significantly improved image quality in lower-limb angiography with metal implants, compared to DSA imaging. The improved CNR suggest that this approach could reduce radiation exposure for lower-limb angiography with metal implants. LEVEL OF EVIDENCE: Level 4, case studies.

Entities:  

Keywords:  Automated exposure control; Contrast-to-noise ratio; Digital variance angiography; Metal implants

Mesh:

Substances:

Year:  2020        PMID: 33145701      PMCID: PMC7864852          DOI: 10.1007/s00270-020-02697-x

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  17 in total

1.  The principle of digital subtraction angiography and radiological protection.

Authors:  K Okamoto; J Ito; K Sakai; S Yoshimura
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

2.  Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy.

Authors:  Pei-Jan Paul Lin
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

3.  Motion based X-ray imaging modality.

Authors:  Krisztián Szigeti; Domokos Máthé; Szabolcs Osváth
Journal:  IEEE Trans Med Imaging       Date:  2014-06-10       Impact factor: 10.048

4.  Digital Variance Angiography as a Paradigm Shift in Carbon Dioxide Angiography.

Authors:  Viktor Imre Óriás; Marcell Gyánó; István Góg; Dávid Szöllősi; Dániel Sándor Veres; Zsuzsa Nagy; Csaba Csobay-Novák; Oláh Zoltán; János P Kiss; Szabolcs Osváth; Krisztián Szigeti; Ruzsa Zoltán; Péter Sótonyi
Journal:  Invest Radiol       Date:  2019-07       Impact factor: 6.016

5.  Carbon dioxide (CO2) angiography as an option for endovascular abdominal aortic aneurysm repair (EVAR) in patients with chronic kidney disease (CKD).

Authors:  Chiara De Angelis; Francesco Sardanelli; Matteo Perego; Marco Alì; Francesco Casilli; Luigi Inglese; Giovanni Mauri
Journal:  Int J Cardiovasc Imaging       Date:  2017-05-27       Impact factor: 2.357

Review 6.  Contrast alternatives for iodinated contrast allergy and renal dysfunction: options and limitations.

Authors:  Gregory J Nadolski; S William Stavropoulos
Journal:  J Vasc Surg       Date:  2012-12-14       Impact factor: 4.268

7.  Image noise reduction algorithm for digital subtraction angiography: clinical results.

Authors:  Michael Söderman; Staffan Holmin; Tommy Andersson; Charlotta Palmgren; Draženko Babic; Bart Hoornaert
Journal:  Radiology       Date:  2013-06-04       Impact factor: 11.105

Review 8.  Carbon dioxide in angiography to reduce the risk of contrast-induced nephropathy.

Authors:  Irvin F Hawkins; Kyung J Cho; James G Caridi
Journal:  Radiol Clin North Am       Date:  2009-09       Impact factor: 2.303

9.  Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose.

Authors:  Ruediger E Schernthaner; Reham R Haroun; Sonny Nguyen; Rafael Duran; Jae Ho Sohn; Sonia Sahu; Julius Chapiro; Yan Zhao; Alessandro Radaelli; Imramsjah M van der Bom; Maria Mauti; Kelvin Hong; Jean-François H Geschwind; MingDe Lin
Journal:  Cardiovasc Intervent Radiol       Date:  2017-10-31       Impact factor: 2.740

10.  Initial Operating Room Experience with Digital Variance Angiography in Carbon Dioxide-Assisted Lower Limb Interventions: A Pilot Study.

Authors:  Marcell Gyánó; Csaba Csobay-Novák; Márton Berczeli; István Góg; János P Kiss; Krisztián Szigeti; Szabolcs Osváth; Balázs Nemes
Journal:  Cardiovasc Intervent Radiol       Date:  2020-05-31       Impact factor: 2.740

View more
  4 in total

1.  Digital Variance Angiography: A Promising Alternative Technology to Traditional Angiography for Improvement of Image Quality with Reduction of Radiation and Contrast Medium Doses.

Authors:  Zhonghua Sun
Journal:  Cardiovasc Intervent Radiol       Date:  2021-01-03       Impact factor: 2.740

2.  Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions.

Authors:  Viktor I Óriás; Dávid Szöllősi; Marcell Gyánó; Dániel S Veres; Sándor Nardai; Csaba Csobay-Novák; Balázs Nemes; János P Kiss; Krisztián Szigeti; Szabolcs Osváth; Péter Sótonyi; Zoltán Ruzsa
Journal:  Eur J Radiol Open       Date:  2020-11-17

3.  Digital Variance Angiography in Selective Lower Limb Interventions.

Authors:  Rohit P Thomas; Moritz B Bastian; Simon Viniol; Alexander M König; Sandeep S Amin; Osama Eldergash; Johannes Schnabel; Marcell Gyánó; Dávid Szöllősi; István Góg; János P Kiss; Szabolcs Osváth; Krisztián P Szigeti; Andreas H Mahnken
Journal:  J Vasc Interv Radiol       Date:  2021-10-13       Impact factor: 3.464

4.  Digital variance angiography allows about 70% decrease of DSA-related radiation exposure in lower limb X-ray angiography.

Authors:  Marcell Gyánó; Márton Berczeli; Csaba Csobay-Novák; Dávid Szöllősi; Viktor I Óriás; István Góg; János P Kiss; Dániel S Veres; Krisztián Szigeti; Szabolcs Osváth; Ákos Pataki; Viktória Juhász; Zoltán Oláh; Péter Sótonyi; Balázs Nemes
Journal:  Sci Rep       Date:  2021-11-08       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.