| Literature DB >> 33109799 |
Tanveer Singh Kundra1, Ashwini Thimmarayappa2, Sunder Singh Subash3, Parminder Kaur4.
Abstract
Background: Intra and postoperative perfusion monitoring should be used in critical limb ischemia patients undergoing vascular surgery to improve outcomes and reduce costs. While a pulse oximeter can be applied on the affected limb to monitor the arterial saturation of the limb, thus reflecting flow in that limb, we need to focus on other important parameters like muscle oxygen consumption and regional blood flow for a good outcome. Near-infrared spectroscopy (NIRS) can be used in such patients to monitor regional and tissue oxygenation. Methodology: In this prospective observational study, 30 adult patients undergoing infra-inguinal bypass were recruited. All these patients were given combined spinal-epidural anesthesia. In addition to routine monitoring, a pulse oximeter and NIRS electrodes were applied on the affected limb. rsO2, limb spO2, and Doppler signals were noted before the induction of anesthesia (baseline) and postoperatively at 0, 6, and 12 h. Improvement in rsO2 and limb spO2 values after surgery was noted and fall in these values was evaluated. Pearson correlation between rsO2 and limb spO2 was assessed. The data was analyzed using repeated-measures ANOVA.Entities:
Keywords: Near-infrared spectroscopy; rest pain; tissue perfusion
Year: 2020 PMID: 33109799 PMCID: PMC7879884 DOI: 10.4103/aca.ACA_137_19
Source DB: PubMed Journal: Ann Card Anaesth ISSN: 0971-9784
Demographics and co-morbidities of the recruited patients
| Demographic variables and co-morbid conditions | Observed values/ number of patients with the co-morbid condition |
|---|---|
| Age (in years) | 55.24±10.54 |
| Sex (Male:Female) | 22: 8 |
| Diabetes Mellitus | 18 |
| Hypertension | 20 |
| H/o any previous neurological event (TIA, stroke, motor weakness) | 5 |
| H/o any previous cardiac event (chest pain, MI) | 2 |
Pearson correlation values between rsO2 and spO2
| Correlation coefficient | |
|---|---|
| Baseline | 0.99 |
| At 6 h | 0.90 |
| At 12 h | 0.91 |
Improvement observed in rsO2 values and limb spO2 values after establishment of flow
| Baseline | Post-procedure | At 6 h | At 12 h | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mean | Std. error | 95%CI | Mean | Std. error | 95%CI | Mean | Std. error | 95%CI | Mean | Std. error | 95% CI | ||||
| rsO2 | 27.27 | 3.92 | 19.25-35.28 | 41.97 | 1.25 | 39.42-44.51 | 0.00* | 48.20 | 1.57 | 44.99-51.41 | 0.00* | 53.57 | 2.41 | 48.64-58.49 | <0.00* |
| Limb spO2 | 38.13 | 5.25 | 27.40-48.87 | 58.13 | 1.64 | 54.78-61.48 | 0.00* | 68.47 | 2.65 | 63.04-73.89 | 0.00* | 74.67 | 3.57 | 67.36-81.97 | <0.00* |
*P significant when compared with baseline value