Literature DB >> 33092461

Pipeline Flex embolisation device with Shield Technology for the treatment of patients with intracranial aneurysms: periprocedural and 6 month outcomes.

James Yeomans1, Lilian Sandu1, Anand Sastry1.   

Abstract

BACKGROUND AND
PURPOSE: The Pipeline Flex embolisation device with Shield Technology (Pipeline Shield) is a novel flow diverter which reduces intra-vessel thrombogenicity. This study summarises periprocedural outcomes and 6-month follow-up results following its introduction in a tertiary interventional neuroradiology centre.
MATERIALS AND METHODS: This prospective, single-arm study assessed 32 aneurysms treated over a 21-month time period from the time of procedure to 6 months post-procedure. Data collected included patient demographics, aneurysm features and intraprocedural and 6-month post-procedural complications.
RESULTS: The mean age of the cohort was 58.8 ± Standard Deviation 8.5 years. Twenty-eight aneurysms were treated electively and four acutely. The elective cases received dual antiplatelet therapy post-procedure. The acute cases received single antiplatelet therapy post-procedure. Of the target aneurysms, 16/32 (50%) were small (<10 mm), 13/32 (41%) were large (10-25 mm) and 3/32 (9%) were giant (≥25 mm). There was no mortality in the series. There were two periprocedural complications (2/32, 6.2%): a stroke and a dissection. There were no post-procedural complications. At 6 months post-procedure, satisfactory occlusion (defined as Raymond-Roy 1 or 2) was achieved in 90.6% and 93.8% by way of magnetic resonance angiography and digital subtraction angiography assessment, respectively. There was no implant migration, no significant intraluminal hyperplasia or in-stent stenosis and no cases of aneurysm recurrence.
CONCLUSION: The Pipeline Shield has an excellent 6- month safety profile with an acceptable rate of intraprocedural complications, no post-procedure complications and no mortality in this case series of 32 acute and elective cases.

Entities:  

Keywords:  Aneurysm; Pipeline; flow diverter

Year:  2020        PMID: 33092461      PMCID: PMC7788678          DOI: 10.1177/1971400920966749

Source DB:  PubMed          Journal:  Neuroradiol J        ISSN: 1971-4009


  32 in total

1.  A second-generation, endoluminal, flow-disrupting device for treatment of saccular aneurysms.

Authors:  D F Kallmes; Y H Ding; D Dai; R Kadirvel; D A Lewis; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2009-04-15       Impact factor: 3.825

2.  New Pipeline Flex device: initial experience and technical nuances.

Authors:  Vitor Mendes Pereira; Michael Kelly; Pedro Vega; Eduardo Murias; Hasan Yilmaz; Gorislav Erceg; Alain Pellaton; Karl-olof Lovblad; Timo Krings
Journal:  J Neurointerv Surg       Date:  2014-10-03       Impact factor: 5.836

3.  FRED Flow Diverter: A Study on Safety and Efficacy in a Consecutive Group of 50 Patients.

Authors:  H Luecking; T Engelhorn; S Lang; P Goelitz; S Kloska; K Roessler; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2017-01-19       Impact factor: 3.825

4.  Endovascular treatment of unruptured aneurysms.

Authors:  D Roy; G Milot; J Raymond
Journal:  Stroke       Date:  2001-09       Impact factor: 7.914

Review 5.  Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis.

Authors:  Waleed Brinjikji; Mohammad H Murad; Giuseppe Lanzino; Harry J Cloft; David F Kallmes
Journal:  Stroke       Date:  2013-01-15       Impact factor: 7.914

6.  Stroke: current concepts.

Authors:  Megan Albertson; Jitendra Sharma
Journal:  S D Med       Date:  2014-11

7.  Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the pipeline embolization device.

Authors:  David Fiorella; Henry H Woo; Felipe C Albuquerque; Peter K Nelson
Journal:  Neurosurgery       Date:  2008-05       Impact factor: 4.654

8.  Aneurysm Study of Pipeline in an Observational Registry (ASPIRe).

Authors:  David F Kallmes; Waleed Brinjikji; Edoardo Boccardi; Elisa Ciceri; Orlando Diaz; Rabih Tawk; Henry Woo; Pascal Jabbour; Felipe Albuquerque; Rene Chapot; Alain Bonafe; Shervin R Dashti; Josser E Delgado Almandoz; Curtis Given; Michael E Kelly; DeWitte T Cross; Gary Duckwiler; Nasser Razack; Ciaran J Powers; Sebastian Fischer; Demetrius Lopes; Mark R Harrigan; Daniel Huddle; Raymond Turner; Osama O Zaidat; Luc Defreyne; Vitor Mendes Pereira; Saruhan Cekirge; David Fiorella; Ricardo A Hanel; Pedro Lylyk; Cameron McDougall; Adnan Siddiqui; Istvan Szikora; Elad Levy
Journal:  Interv Neurol       Date:  2016-05-26

9.  Current Treatment Strategies for Intracranial Aneurysms: An Overview.

Authors:  Junjie Zhao; Hao Lin; Richard Summers; Mingmin Yang; Brian G Cousins; Janice Tsui
Journal:  Angiology       Date:  2017-03-30       Impact factor: 3.619

10.  Treatment of intracranial aneurysms using the pipeline flex embolization device with shield technology: angiographic and safety outcomes at 1-year follow-up.

Authors:  Mario Martínez-Galdámez; Saleh M Lamin; Konstantinos G Lagios; Thomas Liebig; Elisa F Ciceri; Rene Chapot; Luc Stockx; Swarupsinh Chavda; Christoph Kabbasch; Giuseppe Faragò; Hannes Nordmeyer; Thierry Boulanger; Mariangela Piano; Edoardo P Boccardi
Journal:  J Neurointerv Surg       Date:  2018-09-27       Impact factor: 5.836

View more
  4 in total

Review 1.  Delayed leukoencephalopathy from suspected polymer embolism after neuroendovascular procedures.

Authors:  Thomas Mellemkjær; Ronil V Chandra; Lasse Speiser; Benedicte P Ulhøi; Claus Z Simonsen
Journal:  Neuroradiol J       Date:  2021-07-05

Review 2.  Biomimetic materials based on zwitterionic polymers toward human-friendly medical devices.

Authors:  Kazuhiko Ishihara
Journal:  Sci Technol Adv Mater       Date:  2022-09-13       Impact factor: 7.821

3.  The Silk Vista Baby - The UK experience.

Authors:  P Bhogal; Hld Makalanda; K Wong; P Keston; J Downer; J C Du Plessis; A Nania; D Simonato; M Fuschi; W Chong; S O'Reilly; I Rennie
Journal:  Interv Neuroradiol       Date:  2021-06-02       Impact factor: 1.764

4.  Early clinical experience with the p48MW HPC and p64MW HPC flow diverters in the anterior circulation aneurysm using single anti-platelet treatment.

Authors:  Pervinder Bhogal; Andrey Petrov; Ganbaatar Rentsenkhu; Baatarjan Nota; Erdenebat Ganzorig; Boldbat Regzengombo; Sara Jagusch; Elina Henkes; Hans Henkes
Journal:  Interv Neuroradiol       Date:  2021-07-07       Impact factor: 1.764

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.