Fast Acting Insulin Aspart Compared with Insulin Aspart in the Medtronic 670G Hybrid Closed Loop System in Type 1 Diabetes: An Open Label Crossover Study.

Kerem Ozer1, Alison M Cooper1, Lily P Ahn1, Cassidy R Waggonner1, Thomas C Blevins1.   

Abstract

This is a single-center randomized open label active-controlled crossover trial comparing efficacy and safety of fast acting insulin aspart (FA) (FIASP®) versus insulin aspart (IAsp) (NovoLog®) when used in the Medtronic 670G system in auto mode in patients with type 1 diabetes. Forty patients were randomized to either IAsp or FA. Each treatment period was 7 weeks and a standardized meal test was administered 6 weeks after the start of each treatment period. The primary endpoint was postprandial glucose (PPG) increment after the meal test at 1 h. Treatment with FA using the MiniMed 670G hybrid closed loop (HCL) led to a greater reduction in 1-h postprandial glucose increase compared with treatment with IAsp during the standardized mixed meal test. Change in glucose: [estimated treatment difference (ETD ± standard deviation [SD]); 95% confidence interval]: 70.27 (±17.36) mg/dL (3.9 ± 1.0 mmol/L) with FA versus 98.42 (±17.36) mg/dL (5.5 ± 1.0 mmol/L) with IAsp (P = 0.008). Patients spent 1.81% (P = 0.016) more time (equivalent to 26 min per day) in the 70-180 mg/dL (3.89-9.99 mmol/L) range with FA than with IAsp. The entire sample spent only 0.5% of time <54 mg/dL (<3.0 mmol/L) range. The increment in the 1 h postmeal test glucose was significantly lower with FA versus IAsp. FA in a HCL setting is safe and effective with patients spending more time in the 70-180 mg/dL (3.89-9.99 mmol/L) target range than with IAsp. Trial registration: Clinicaltrials.gov identifier: NCT03977727.

Entities:  

Keywords:  Fast acting insulin aspart; Medtronic 670G hybrid closed loop; Type 1 diabetes

Year:  2021        PMID: 33090016      PMCID: PMC7994433          DOI: 10.1089/dia.2020.0500

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  4 in total

1.  A Comparison of Postprandial Glucose Control in the Medtronic Advanced Hybrid Closed-Loop System Versus 670G.

Authors:  Stuart A Weinzimer; Ryan J Bailey; Richard M Bergenstal; Revital Nimri; Roy W Beck; Desmond Schatz; Louise Ambler-Osborn; Darja Smigoc Schweiger; Thekla von dem Berge; Judy Sibayan; Mary L Johnson; Peter Calhoun; Moshe Phillip
Journal:  Diabetes Technol Ther       Date:  2022-04-28       Impact factor: 7.337

2.  Adjunctive Therapies to Optimize Closed-loop Glucose Control.

Authors:  Shylaja Srinivasan; Laya Ekhlaspour; Eda Cengiz
Journal:  J Diabetes Sci Technol       Date:  2021-07-27

Review 3.  Dual-hormone artificial pancreas for management of type 1 diabetes: Recent progress and future directions.

Authors:  Marco Infante; David A Baidal; Michael R Rickels; Andrea Fabbri; Jay S Skyler; Rodolfo Alejandro; Camillo Ricordi
Journal:  Artif Organs       Date:  2021-07-15       Impact factor: 2.663

Review 4.  What is the value of faster acting prandial insulin? Focus on ultra rapid lispro.

Authors:  Tim Heise; Carolina Piras de Oliveira; Rattan Juneja; Anderson Ribeiro; Farai Chigutsa; Thomas Blevins
Journal:  Diabetes Obes Metab       Date:  2022-06-15       Impact factor: 6.408

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.