| Literature DB >> 33082292 |
Matthias Bechstein1, Samer Elsheikh2, Fritz Wodarg3, Christian A Taschner2, Uta Hanning4, Jan-Hendrik Buhk5, Rosalie McDonough4, Einar Goebell4, Jens Fiehler4, Maxim Bester4.
Abstract
This is a report of the first three cases of endovascular aneurysm treatment that were proctored by a remote interventionalist using a novel high-resolution low-latency streaming technology. The proctor was located in a neurovascular centre and supported the treating interventional teams in two distant cities (up to 800 km/500 miles apart). All aneurysms were treated using the Woven EndoBridge (WEB) embolisation system, either electively or following subarachnoid haemorrhage. On-site proctoring was not possible due to travel restrictions during the COVID-19 pandemic. WEB placement was feasible in all cases. Good rapport between proctors and treating physicians was reported, enabled by the high-resolution image transmission and uninterrupted feedback/discussion via audiostream. No clinical complications were encountered. Short-term follow-up revealed adequate occlusion of all treated aneurysms. The employed streaming technology provided effective remote proctoring during complex aneurysm cases, including the management of technical complications. © BMJ Publishing Group Limited 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.Entities:
Keywords: aneurysm; angiography; intervention; subarachnoid
Mesh:
Year: 2020 PMID: 33082292 DOI: 10.1136/neurintsurg-2020-016722.rep
Source DB: PubMed Journal: J Neurointerv Surg ISSN: 1759-8478 Impact factor: 5.836