Literature DB >> 33068127

Component gap measurement reflects the planned gap balance during total knee arthroplasty more accurately and reliably than bone surface gap measurement.

Kyun-Ho Shin1, Ki-Mo Jang1, Seung-Beom Han2.   

Abstract

PURPOSE: This study aimed to compare the reliability of two gap assessment methods (component and bone surface gap measurement vs. planned gap balance) and identify the contributors to component gaps other than planned gaps.
METHODS: The prospectively collected data for 122 consecutive primary total knee arthroplasties (TKAs; 114 patients). After femoral planning for gap balancing, the medial and lateral planned gaps were calculated (planned gap). The established medial extension and flexion gaps (MEG and MFG, respectively) and lateral extension and flexion gaps (LEG and LFG, respectively) were measured with and without the TKA components (bone surface and component gaps) at 0° and 90° flexion. The intraclass and Pearson correlation coefficients for each gap measurement method were assessed using planned gap values, and multiple linear regression analyses were performed to identify the contributors to component gaps.
RESULTS: Compared with the bone surface gap measurement, the component gap measurement showed higher reliability and stronger correlation with the planned gap balance for each gap. The changes in the medial posterior femoral offset contributed to the MEG and LEG, whereas those in the joint line height contributed to the LEG. The changes in the hip-knee-ankle angle and lateral posterior femoral offset contributed to the LFG.
CONCLUSION: Component gap measurements of the established gap more accurately and reliably reflect the planned gap balance than do bone surface gap measurements. The established gaps are affected by several factors other than femoral planning.
© 2020. European Society of Sports Traumatology, Knee Surgery, Arthroscopy (ESSKA).

Entities:  

Keywords:  Computer-assisted surgeries; Gap balancing; Gap measurement; Laxity; Total knee arthroplasty; Total knee replacement

Mesh:

Year:  2020        PMID: 33068127     DOI: 10.1007/s00167-020-06324-7

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.114


  16 in total

Review 1.  Computer assisted navigation in knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song
Journal:  Clin Orthop Surg       Date:  2011-12-01

2.  Joint gap changes with patellar tendon strain and patellar position during TKA.

Authors:  Ryuichi Gejo; Yuji Morita; Isao Matsushita; Kazuhito Sugimori; Tomoatsu Kimura
Journal:  Clin Orthop Relat Res       Date:  2008-02-09       Impact factor: 4.176

3.  The effect of overstuffing the patellofemoral joint on the extensor retinaculum of the knee.

Authors:  K M Ghosh; A M Merican; F Iranpour; D J Deehan; Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-06-13       Impact factor: 4.342

4.  Bone landmarks are more reliable than tensioned gaps in TKA component alignment.

Authors:  Hirofumi Hanada; Leo A Whiteside; Jerry Steiger; Paul Dyer; Masatoshi Naito
Journal:  Clin Orthop Relat Res       Date:  2007-09       Impact factor: 4.176

5.  Frontal plane knee alignment: a call for standardized measurement.

Authors:  T Derek V Cooke; Elizabeth A Sled; R Allan Scudamore
Journal:  J Rheumatol       Date:  2007-09       Impact factor: 4.666

6.  Modern total knee arthroplasty designs do not reliably replicate anterior femoral morphology.

Authors:  Alexander W Kuo; Darren B Chen; Jil Wood; Samuel J MacDessi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-07-27       Impact factor: 4.342

7.  Phenotyping the knee in young non-osteoarthritic knees shows a wide distribution of femoral and tibial coronal alignment.

Authors:  Michael T Hirschmann; Lukas B Moser; Felix Amsler; Henrik Behrend; Vincent Leclercq; Silvan Hess
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-04-12       Impact factor: 4.342

8.  Functional knee phenotypes: a novel classification for phenotyping the coronal lower limb alignment based on the native alignment in young non-osteoarthritic patients.

Authors:  Michael T Hirschmann; Lukas B Moser; Felix Amsler; Henrik Behrend; Vincent Leclerq; Silvan Hess
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-04-11       Impact factor: 4.342

9.  Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee.

Authors:  N Bellamy; W W Buchanan; C H Goldsmith; J Campbell; L W Stitt
Journal:  J Rheumatol       Date:  1988-12       Impact factor: 4.666

10.  What Factors Are Associated With Femoral Component Internal Rotation in TKA Using the Gap Balancing Technique?

Authors:  Seung-Yup Lee; Hong-Chul Lim; Ki-Mo Jang; Ji-Hoon Bae
Journal:  Clin Orthop Relat Res       Date:  2017-03-23       Impact factor: 4.176

View more