Literature DB >> 31352496

Modern total knee arthroplasty designs do not reliably replicate anterior femoral morphology.

Alexander W Kuo1, Darren B Chen2, Jil Wood2, Samuel J MacDessi3,4.   

Abstract

PURPOSE: Biomechanical studies suggest that PF tracking is not reliably restored to physiological values in TKA despite surgical technique optimization. A clinical observation is that current TKA designs may not replicate anterior femoral offset. The aim was to examine the intraoperative resection thicknesses of the anterior femoral condyles during TKA and correlate these findings relative to modern prostheses.
METHODS: This was a retrospective analysis of 199 patients who underwent 233 TKAs using a single implant design with measured anterior femoral condylar resection thicknesses. The aim was to restore posterior condylar offset whilst minimizing overstuffing of the anterior compartment of the knee by choosing the smallest prosthesis to allow for the maximal anterior resection as close to the cortex without inducing notching. Prosthetic measurements from 7 commonly used TKAs were collected by analysis of 3D models of median sized explants.
RESULTS: An average of 7.9 mm (SD 2.5 mm, range 2-16.5 mm) and 11.5 mm (SD 2.5 mm, range 2-21 mm) was resected from the medial and lateral aspects of the anterior femur, respectively. The average anterior flange thickness for the prosthesis data set was 6.6 mm (SD 0.6 mm, range 6.1-7.9 mm) medially and 7.6 mm (SD 0.7 mm, range 6.8-9.0 mm) laterally. Comparison across patients who received the median prosthesis size of 5 (SD 1.3, range 2-8) was inadequately restored by 1.4 mm (p < 0.00001) medially and 3.4 mm (p < 0.00001) laterally.
CONCLUSION: Host anatomy is not routinely restored during TKA. The surgical teaching to aim for an anterior femoral osteotomy close to the anterior cortex will result in understuffing of the PFJ and based on current prosthesis designs, the risk of overstuffing is not as significant as once believed. Future prostheses and surgical techniques should aim to restore not only posterior femoral but also anterior femoral offset. LEVEL OF EVIDENCE: IV, Case series.

Entities:  

Keywords:  Anterior condyles; Femoral offset; Patellofemoral; Total knee arthroplasty; Total knee replacement; Trochlear morphology

Mesh:

Year:  2019        PMID: 31352496     DOI: 10.1007/s00167-019-05610-3

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  4 in total

1.  Alignment philosophy influences trochlea recreation in total knee arthroplasty: a comparative study using image-based robotic technology.

Authors:  Jobe Shatrov; Benoit Coulin; Cécile Batailler; Elvire Servien; Bill Walter; Sebastien Lustig
Journal:  Int Orthop       Date:  2022-09-16       Impact factor: 3.479

2.  Component gap measurement reflects the planned gap balance during total knee arthroplasty more accurately and reliably than bone surface gap measurement.

Authors:  Kyun-Ho Shin; Ki-Mo Jang; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-10-17       Impact factor: 4.114

Review 3.  Patella resurfacing during total knee arthroplasty is cost-effective and has lower re-operation rates compared to non-resurfacing.

Authors:  Thomas Parsons; Talal Al-Jabri; Nick D Clement; Nicola Maffulli; Deiary F Kader
Journal:  J Orthop Surg Res       Date:  2021-03-11       Impact factor: 2.359

4.  Functional Alignment Philosophy in Total Knee Arthroplasty - Rationale and technique for the varus morphotype using a CT based robotic platform and individualized planning.

Authors:  Jobe Shatrov; Cécile Battelier; Elliot Sappey-Marinier; Stanislas Gunst; Elvire Servien; Sebastien Lustig
Journal:  SICOT J       Date:  2022-04-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.