Alice Macchiavelli1, Antonella Giffone2, Francesco Ferrarello3, Matteo Paci4. 1. School of Physiotherapy, University of Florence, Florence, Italy. 2. IRCCS Fondazione Don Gnocchi, Florence, Italy. 3. Unit of Functional Rehabilitation, Azienda USL Toscana Centro, Prato, Italy. 4. Unit of Functional Rehabilitation, Azienda USL Toscana Centro, Florence, Italy. matteo.paci@applicazione.it.
Abstract
PURPOSE: The six-minute walking test (6MWT) is a simple and widely used measure of functional capacity. The aim of this systematic review is to summarize findings on reliability of 6MWT in subjects who have had a stroke. METHODS: Two independent investigators conducted an extensive search in multidisciplinary electronic databases from inception to August 2019, and selected complete original studies on the reliability of the 6MWT used to assess individuals with stroke. Two reviewers independently extracted data and evaluated methodological quality. Outcome for meta-analysis was reliability, measured by intraclass correlation coefficient (ICC). In addition, standard error of measurement (SEM) and minimal detectable change (MDC) were recorded. RESULTS: Of the 241 potentially relevant articles screened, 6 met inclusion criteria and 5 of them were included in meta-analysis. Combined correlation coefficient of .98 (confidence interval .98-.99) was found for test-retest reliability. Only one study investigated inter-rater and intra-rater reliability. SEM and MDC values were rarely reported. CONCLUSIONS: The 6MWT has high test-retest reliability, when used to assess individuals with stroke. Other types of reliability and SEM and MDC need further investigations in populations with a stroke.
PURPOSE: The six-minute walking test (6MWT) is a simple and widely used measure of functional capacity. The aim of this systematic review is to summarize findings on reliability of 6MWT in subjects who have had a stroke. METHODS: Two independent investigators conducted an extensive search in multidisciplinary electronic databases from inception to August 2019, and selected complete original studies on the reliability of the 6MWT used to assess individuals with stroke. Two reviewers independently extracted data and evaluated methodological quality. Outcome for meta-analysis was reliability, measured by intraclass correlation coefficient (ICC). In addition, standard error of measurement (SEM) and minimal detectable change (MDC) were recorded. RESULTS: Of the 241 potentially relevant articles screened, 6 met inclusion criteria and 5 of them were included in meta-analysis. Combined correlation coefficient of .98 (confidence interval .98-.99) was found for test-retest reliability. Only one study investigated inter-rater and intra-rater reliability. SEM and MDC values were rarely reported. CONCLUSIONS: The 6MWT has high test-retest reliability, when used to assess individuals with stroke. Other types of reliability and SEM and MDC need further investigations in populations with a stroke.
Entities:
Keywords:
Outcome assessment; Outcomes; Reliability; Stroke; Walk test
Authors: Shamay S Ng; William W Tsang; Tracy H Cheung; Josiben S Chung; Fenny P To; Phoebe C Yu Journal: Arch Phys Med Rehabil Date: 2011-05 Impact factor: 3.966
Authors: L B Mokkink; H C W de Vet; C A C Prinsen; D L Patrick; J Alonso; L M Bouter; C B Terwee Journal: Qual Life Res Date: 2017-12-19 Impact factor: 4.147