Literature DB >> 33063486

[Clinical observation of arthroscopic all-inside combined with outside-in "suture loop" repair for meniscus bucket-handle tear].

Yong Jia1, Gang Xu1, Chunqing He1, Fei Zhang1, Jian Liu1, Pengbo Wang1.   

Abstract

OBJECTIVE: To investigate the effectiveness of arthroscopic all-inside combined with outside-in "suture loop" repair for meniscus bucket-handle tear (BHT).
METHODS: Between August 2016 and May 2019, 44 case of meniscus BHT were treated with arthroscopic all-inside combined outside-in "suture loop". There were 29 males and 15 females with an average age of 26.6 years (range, 18-42 years). The causes of injury included sports injury in 31 cases, falling injury in 7 cases, and sprain in 6 cases. There were 32 cases of medial meniscus posterior horn tears and 12 cases of lateral meniscus posterior horn tears. The disease duration ranged from 6 weeks to 3 months. Thirty-three cases were complicated with anterior cruciate ligament rupture. All patients had normal lower limb alignment. The preoperative Lysholm score was 42.1±9.1. According to the evaluation criteria of MRI and Barrett et al., the healing of meniscus was evaluated, and the effectiveness was evaluated by Lysholm score.
RESULTS: All the 44 patients were followed up 8-36 months with an average of 16.8 months. At last follow-up, according to the evaluation criteria of Barrett et al., 39 cases were clinically healed, 5 cases were not healed, the clinical healing rate was 88.6%; according to MRI evaluation, 32 cases were completely healed, 7 cases were partially healed, and 5 cases were not healed, the total healing rate was 88.6%, and the complete healing rate was 72.7%. Lysholm score was 87.8±4.8, which was significantly different from that before operation ( t=31.060, P=0.000).
CONCLUSION: Arthroscopic all-inside combined with outside-in "suture loop" repair is a reliable and effective method for the meniscus BHT, which can obtain good joint function.

Entities:  

Keywords:  Menisics; arthroscope; bucket-handle tear; outside-in “suture loop” repair

Mesh:

Year:  2020        PMID: 33063486      PMCID: PMC8171879          DOI: 10.7507/1002-1892.202003132

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  15 in total

1.  Bucket-handle meniscal tears of the knee: sensitivity and specificity of MRI signs.

Authors:  Theodore A Dorsay; Clyde A Helms
Journal:  Skeletal Radiol       Date:  2003-03-20       Impact factor: 2.199

2.  How effective is multiple needle puncturing for medial soft tissue balancing during total knee arthroplasty? A cadaveric study.

Authors:  In Jun Koh; Dai-Soon Kwak; Tae Kyun Kim; In Joo Park; Yong In
Journal:  J Arthroplasty       Date:  2013-11-09       Impact factor: 4.757

3.  In vivo mechanical behaviour of the anterior cruciate ligament: A study of six daily and high impact activities.

Authors:  Elisa Roldán; Neil D Reeves; Glen Cooper; Kirstie Andrews
Journal:  Gait Posture       Date:  2017-08-01       Impact factor: 2.840

4.  Effects of suture site or penetration depth on anchor location in all-inside meniscal repair.

Authors:  Ryohei Uchida; Tatsuo Mae; Kunihiko Hiramatsu; Ryo Iuchi; Kazutaka Kinugasa; Konsei Shino; Hideki Yoshikawa; Ken Nakata
Journal:  Knee       Date:  2016-10-29       Impact factor: 2.199

5.  Thomas Annandale: the first meniscus repair.

Authors:  Berardo Di Matteo; Vittorio Tarabella; Giuseppe Filardo; Anna Viganò; Patrizia Tomba; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-11       Impact factor: 4.342

6.  Comparable Outcomes After Bucket-Handle Meniscal Repair and Vertical Meniscal Repair Can Be Achieved at a Minimum 2 Years' Follow-up.

Authors:  Gilbert Moatshe; Mark E Cinque; Jonathan A Godin; Alexander R Vap; Jorge Chahla; Robert F LaPrade
Journal:  Am J Sports Med       Date:  2017-08-14       Impact factor: 6.202

7.  The role of the meniscus in the anterior-posterior stability of the loaded anterior cruciate-deficient knee. Effects of partial versus total excision.

Authors:  S C Shoemaker; K L Markolf
Journal:  J Bone Joint Surg Am       Date:  1986-01       Impact factor: 5.284

8.  Meniscal repair using the FasT-Fix all-inside meniscal repair device.

Authors:  Andrew L Haas; Anthony A Schepsis; Joshua Hornstein; Cory M Edgar
Journal:  Arthroscopy       Date:  2005-02       Impact factor: 4.772

9.  Meniscal repair with the RapidLoc meniscal repair device.

Authors:  F Alan Barber; David A Coons; Michell Ruiz-Suarez
Journal:  Arthroscopy       Date:  2006-09       Impact factor: 4.772

10.  Preliminary results of the T-fix endoscopic meniscus repair technique in an anterior cruciate ligament reconstruction population.

Authors:  G R Barrett; S H Treacy; C G Ruff
Journal:  Arthroscopy       Date:  1997-04       Impact factor: 4.772

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.