Effects of suture site or penetration depth on anchor location in all-inside meniscal repair.

Ryohei Uchida1, Tatsuo Mae2, Kunihiko Hiramatsu3, Ryo Iuchi4, Kazutaka Kinugasa3, Konsei Shino4, Hideki Yoshikawa3, Ken Nakata3.   

Abstract

BACKGROUND: To evaluate the effects of suture site or penetration depth on anchor location in all-inside meniscal repair.
METHODS: Eight fresh-frozen cadaveric knees were evaluated after meniscal repair using eight FasT-Fix360 (FF360) devices (Smith & Nephew Endoscopy, Andover, MA) (16 anchors) for each knee. The penetration depth was 14mm, the distance same from the periphery to insertion point, in four knees (Group A) and that in the remaining four knees (Group B) was 18mm. The anchor location in two groups was evaluated after attentive dissection.
RESULTS: Of 32 anchors for the medial meniscus, 94% were on the capsule, including the superficial medial collateral ligament (sMCL) in both groups. For the lateral meniscus, 47% anchors in Group A and 44% anchors in Group B were on the capsule. Total three anchors were over the lateral collateral ligament (LCL), whereas 15 anchors were behind the popliteus tendon (POP). Although all three anchors settled in the subcutaneous fat were in Group B, no significant difference was observed in anchor location between two groups.
CONCLUSIONS: Secure fixation to thin membranous tissue can be achieved for the medial meniscal repair using FF360, while some were located in/on bunchy LCL or POP in lateral meniscal repair. Only anchors with additional four-millimeter penetration depth were in the subcutaneous fat, although there was no effect of the penetration depth to anchor location. Clinically, for lateral meniscal repair, penetrating toward POP/LCL should be avoided and four-millimeter deeper penetration depth might be a risk for the subcutaneous irritation. Copyright Â
© 2016 Elsevier B.V. All rights reserved.

Keywords:  All-inside technique; Anchor location; Cadaveric study; Meniscal repair; Penetration depth

Mesh:

Year:  2016        PMID: 27802925     DOI: 10.1016/j.knee.2016.06.012

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  2 in total

1.  The popliteus tendon provides a safe and reliable location for all-inside meniscal repair device placement.

Authors:  Hervé Ouanezar; William G Blakeney; Charles Latrobe; Adnan Saithna; Levi Reina Fernandes; Jean Romain Delaloye; Mathieu Thaunat; Bertrand Sonnery-Cottet
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-03       Impact factor: 4.342

2.  [Clinical observation of arthroscopic all-inside combined with outside-in "suture loop" repair for meniscus bucket-handle tear].

Authors:  Yong Jia; Gang Xu; Chunqing He; Fei Zhang; Jian Liu; Pengbo Wang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-10-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.