Literature DB >> 33052845

Phase-Aberration Correction for HIFU Therapy Using a Multielement Array and Backscattering of Nonlinear Pulses.

Gilles P L Thomas, Tatiana D Khokhlova, Christopher R Bawiec, Alex T Peek, Oleg A Sapozhnikov, Matthew O'Donnell, Vera A Khokhlova.   

Abstract

Phase aberrations induced by heterogeneities in body wall tissues introduce a shift and broadening of the high-intensity focused ultrasound (HIFU) focus, associated with decreased focal intensity. This effect is particularly detrimental for HIFU therapies that rely on shock front formation at the focus, such as boiling histotripsy (BH). In this article, an aberration correction method based on the backscattering of nonlinear ultrasound pulses from the focus is proposed and evaluated in tissue-mimicking phantoms. A custom BH system comprising a 1.5-MHz 256-element array connected to a Verasonics V1 engine was used as a pulse/echo probe. Pulse inversion imaging was implemented to visualize the second harmonic of the backscattered signal from the focus inside a phantom when propagating through an aberrating layer. Phase correction for each array element was derived from an aberration-correction method for ultrasound imaging that combines both the beamsum and the nearest neighbor correlation method and adapted it to the unique configuration of the array. The results were confirmed by replacing the target tissue with a fiber-optic hydrophone. Comparing the shock amplitude before and after phase-aberration correction showed that the majority of losses due to tissue heterogeneity were compensated, enabling fully developed shocks to be generated while focusing through aberrating layers. The feasibility of using a HIFU phased-array transducer as a pulse-echo probe in harmonic imaging mode to correct for phase aberrations was demonstrated.

Entities:  

Mesh:

Year:  2021        PMID: 33052845      PMCID: PMC8476183          DOI: 10.1109/TUFFC.2020.3030890

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  44 in total

1.  Propagation of finite amplitude sound through turbulence: modeling with geometrical acoustics and the parabolic approximation.

Authors:  Philippe Blanc-Benon; Bart Lipkens; Laurent Dallois; Mark F Hamilton; David T Blackstock
Journal:  J Acoust Soc Am       Date:  2002-01       Impact factor: 1.840

2.  MR-guided adaptive focusing of therapeutic ultrasound beams in the human head.

Authors:  L Marsac; D Chauvet; B Larrat; M Pernot; B Robert; M Fink; A L Boch; J F Aubry; M Tanter
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

3.  Transcostal high-intensity-focused ultrasound: ex vivo adaptive focusing feasibility study.

Authors:  J-F Aubry; M Pernot; F Marquet; M Tanter; M Fink
Journal:  Phys Med Biol       Date:  2008-05-12       Impact factor: 3.609

4.  Transcranial ultrasonic therapy based on time reversal of acoustically induced cavitation bubble signature.

Authors:  Jérôme Gâteau; Laurent Marsac; Mathieu Pernot; Jean-Francois Aubry; Mickaël Tanter; Mathias Fink
Journal:  IEEE Trans Biomed Eng       Date:  2009-09-18       Impact factor: 4.538

5.  Measurement and correction of ultrasonic pulse distortion produced by the human breast.

Authors:  L M Hinkelman; D L Liu; R C Waag; Q Zhu; B D Steinberg
Journal:  J Acoust Soc Am       Date:  1995-03       Impact factor: 1.840

6.  The effect of abdominal wall morphology on ultrasonic pulse distortion. Part I. Measurements.

Authors:  L M Hinkelman; T D Mast; L A Metlay; R C Waag
Journal:  J Acoust Soc Am       Date:  1998-12       Impact factor: 1.840

7.  Harmonic source wavefront aberration correction for ultrasound imaging.

Authors:  Scott W Dianis; Olaf T von Ramm
Journal:  J Acoust Soc Am       Date:  2011-01       Impact factor: 1.840

8.  Direct estimation of aberrating delays in pulse-echo imaging systems.

Authors:  D Rachlin
Journal:  J Acoust Soc Am       Date:  1990-07       Impact factor: 1.840

Review 9.  Histotripsy methods in mechanical disintegration of tissue: towards clinical applications.

Authors:  Vera A Khokhlova; J Brian Fowlkes; William W Roberts; George R Schade; Zhen Xu; Tatiana D Khokhlova; Timothy L Hall; Adam D Maxwell; Yak-Nam Wang; Charles A Cain
Journal:  Int J Hyperthermia       Date:  2015-02-24       Impact factor: 3.914

10.  Soft-Tissue Aberration Correction for Histotripsy.

Authors:  Jonathan J Macoskey; Timothy L Hall; Jonathan R Sukovich; Sang Won Choi; Kimberly Ives; Eric Johnsen; Charles A Cain; Zhen Xu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

View more
  4 in total

1.  Effects of phase aberration on transabdominal focusing for a large aperture, lowf-number histotripsy transducer.

Authors:  Ellen Yeats; Dinank Gupta; Zhen Xu; Timothy L Hall
Journal:  Phys Med Biol       Date:  2022-07-19       Impact factor: 4.174

2.  Robust and durable aberrative and absorptive phantom for therapeutic ultrasound applications.

Authors:  Alex T Peek; Gilles P L Thomas; Daniel F Leotta; Petr V Yuldashev; Vera A Khokhlova; Tatiana D Khokhlova
Journal:  J Acoust Soc Am       Date:  2022-05       Impact factor: 2.482

3.  Biological current source imaging method based on acoustoelectric effect: A systematic review.

Authors:  Hao Zhang; Minpeng Xu; Miao Liu; Xizi Song; Feng He; Shanguang Chen; Dong Ming
Journal:  Front Neurosci       Date:  2022-07-18       Impact factor: 5.152

4.  Ultrastructural Analysis of Volumetric Histotripsy Bio-effects in Large Human Hematomas.

Authors:  Ekaterina M Ponomarchuk; Pavel B Rosnitskiy; Tatiana D Khokhlova; Sergey V Buravkov; Sergey A Tsysar; Maria M Karzova; Kseniya D Tumanova; Anna V Kunturova; Y-N Wang; Oleg A Sapozhnikov; Pavel E Trakhtman; Nicolay N Starostin; Vera A Khokhlova
Journal:  Ultrasound Med Biol       Date:  2021-06-09       Impact factor: 3.694

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.