Literature DB >> 33047176

Pronator quadratus repair after volar plate fixation in distal radial fractures: evaluation of the clinical and functional outcome and of the protective role on the flexor tendons-a randomized controlled study.

C K Goorens1, P B De Keyzer2,3, K Van Royen3, S Provyn4, J F Goubau3.   

Abstract

The objective was to evaluate pronator quadratus (PQ) repair following volar plating of distal radial fractures on clinical and functional outcome, as well as flexor tendon friction, during the first 12 months in ideally positioned plates (Soong 0). Confounding factors like variation in plate positioning, anatomical consolidation of the fracture and associated lesions were excluded. Eighty patients were included with distal radius fractures treated by volar locking plate in Soong grade 0 position, who were randomized to group PQ repair and group no repair. Sixty-five patients completed the 1-year follow-up: group PQ repair (n = 35) and group no repair (n = 30). Primary outcomes included range of motion, grip strength, pain level and QuickDASH. Secondary outcomes included distance between flexor pollicis longus (FPL) and volar rim and the largest distance between FPL and plate (soft tissue thickness occupied by PQ), assessed by ultrasonography. Mobility, grip strength and QuickDASH revealed no significant differences, except extension was significantly higher only in first 3 months and radial deviation was significantly higher only at 6 weeks after PQ repair. Pain level was significantly lower after PQ repair only in the first 3 months. Distance between FPL and volar rim and the largest distance between FPL and plate were significantly higher after PQ repair. No friction contact between FPL and volar rim was measured in both groups at all measurement moments. Consequently, protective flexor tendon effect of PQ repair could consequently not be concluded. In conclusion, clinical and functional short term benefits, except improved wrist extension and reduced pain in the first 3 months, were not proven in this study. In Soong grade 0, PQ repair is probably not necessary to prevent flexor tendon pathology. In Soong grade 1 or 2, this is still to be investigated. LEVEL OF EVIDENCE: 2.

Entities:  

Keywords:  Distal radius; FPL; PQ; Pronator quadratus repair; Volar plate; Volar rim; Watershed line

Year:  2020        PMID: 33047176     DOI: 10.1007/s00590-020-02804-1

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  1 in total

1.  Pronator quadratus repair after volar plate fixation in distal radial fractures: evaluation of the clinical and functional outcome and of the protective role on the flexor tendons-a randomized controlled study.

Authors:  C K Goorens; P B De Keyzer; K Van Royen; S Provyn; J F Goubau
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-10-12
  1 in total
  3 in total

1.  Pronator quadratus repair after volar plate fixation in distal radial fractures: evaluation of the clinical and functional outcome and of the protective role on the flexor tendons-a randomized controlled study.

Authors:  C K Goorens; P B De Keyzer; K Van Royen; S Provyn; J F Goubau
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-10-12

2.  Evaluation of sparing the pronator quadratus for volar plating of distal radius fractures: a retrospective clinical study.

Authors:  Xiaoxia Huang; Qiyu Jia; Huaqiang Li; Erxat Kerem; Cong Peng; Weiqi Kong; Maimaitiaili Tusunniyazi; Yimurang Hamiti; Dongwei Feng; Yan Zhao
Journal:  BMC Musculoskelet Disord       Date:  2022-06-30       Impact factor: 2.562

3.  Minimally Invasive Pronator Quadratus Sparing Approach versus Extended Flexor Carpi Radialis Approach with Pronator Quadratus Repair for Volar Plating in Distal Radial Fractures.

Authors:  Chul Ki Goorens; Niels Debaenst; Kjell Van Royen; Steven Provyn; Jean F Goubau
Journal:  J Wrist Surg       Date:  2021-07-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.