Abstract
INTRODUCTION: This study aimed to assess the diagnostic performance and the added value to radiologists of different levels of a computer-aided diagnosis (CAD) system for the detection of thyroid cancers.Entities:
Keywords: computer-aided system; diagnosis; thyroid cancer; thyroid nodule; ultrasonography
Year: 2020 PMID: 33042840 PMCID: PMC7518212 DOI: 10.3389/fonc.2020.557169
Source DB: PubMed Journal: Front Oncol ISSN: 2234-943X Impact factor: 6.244
FIGURE 1Representative cases of benign (A) and malignant (B) thyroid nodules. For the benign nodule (A), both the CAD system and the senior and the junior radiologists diagnosed it as a benign nodule. The CAD system rate the nodule of 0.34. For the malignant nodule (B), both the CAD system and the senior and the junior radiologists diagnosed it as a malignant nodule. The CAD system rate the nodule of 0.7.
Characteristics of study subjects.
| Parameter | Value |
| Mean age (years) | 46.4 ± 14.6 |
| Male | 59 (19.5%) |
| Female | 244 (80.5%) |
| Benign nodules | 179 (49%) |
| Malignant nodules | 186 (51%) |
| Total nodules | 18.33 ± 13.5 |
| Benign nodules | 25.58 ± 13.7 |
| Malignant nodules | 11.36 ± 8.8 |
FIGURE 2Determination of the positive threshold for the CAD system score through the Youden index.
Diagnostic performance of CAD System, radiologists and CAD-assisted radiologists.
| Diagnostic measures (%) | Sensitivity | Specificity | PPV | NPV | Accuracy | Area under the ROC curve |
| CAD system | 71.5 (133/186) | 86.0 (154/179) | 84.2 (133/158) | 74.4 (154/207) | 78.6 (287/365) | 0.788 |
| Senior radiologist | 95.2 (177/186) | 86.0 (154/179) | 87.6 (177/202) | 94.5 (154/163) | 90.7 (331/365) | 0.906 |
| CAD + senior radiologist | 97.8 (182/186) | 76.0 (136/179) | 80.9 (182/225) | 97.1 (136/140) | 87.1 (318/365) | 0.869 |
| Junior radiologist | 75.3 (140/186) | 78.8 (141/179) | 78.7 (140/178) | 75.4 (141/187) | 77.0 (281/365) | 0.770 |
| CAD + Junior radiologist | 88.2 (164/186) | 74.3 (133/179) | 78.1 (164/210) | 85.8 (133/155) | 81.4 (297/365) | 0.812 |
| <0.001 | >0.99 | <0.001 | <0.001 | |||
| 0.063 | <0.001 | 0.011 | 0.031 | |||
| 0.419 | 0.024 | 0.586 | 0.552 | |||
| <0.001 | 0.008 | 0.121 | 0.022 | |||
| 0.015 | 0.003 | <0.001 | <0.001 |
FIGURE 3The receiver operating characteristic (ROC) curves for the performance of the computer-aided diagnosis (CAD) system, the senior radiologist, the junior radiologist, and CAD-assisted radiologists.
Comparison of the diagnostic performance of the CAD system in differentiating the thyroid nodules of different sizes.
| Sensitivity (%) | Specificity (%) | Accuracy (%) | |
| 76.3 (116/152) | 65.5 (36/55) | 73.4 (152/207) | |
| 15 < | 55.0 (11/20) | 87.5 (28/32) | 75 (39/52) |
| 42.9 (6/14) | 97.8 (90/92) | 90.5 (96/106) | |
| 0.041 | 0.025 | 0.818 | |
| 0.016* | <0.001* | <0.001* | |