Jay M Patel1,2, Mackenzie L Sennett1,2,3, Anthony R Martin1,2,4, Kamiel S Saleh1,2, Michael R Eby1, Blair S Ashley1, Liane M Miller1,2, George R Dodge1,2, Jason A Burdick1,2,5, James L Carey1, Robert L Mauck1,2,5. 1. McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA. 2. Translational Musculoskeletal Research Center, Corporal Michael J Crescenz VA Medical Center, Philadelphia, PA, USA. 3. Penn State College of Medicine, Pennsylvania State University, Hershey, PA, USA. 4. Miller School of Medicine, University of Miami, Miami, FL, USA. 5. Department of Bioengineering, University of Pennsylvania, Philadelphia PA.
Abstract
OBJECTIVE: Cartilage repair strategies have seen improvement in recent years, especially with the use of scaffolds that serve as a template for cartilage formation. However, current fixation strategies are inconsistent with regards to retention, may be technically challenging, or may damage adjacent tissues or the implant itself. Therefore, the goal of this study was to evaluate the retention and repair potential of cartilage scaffolds fixed with an easy-to-implement bioresorbable pin. DESIGN: Electrospun hyaluronic acid scaffolds were implanted into trochlear groove defects in 3 juvenile and 3 adult pigs to evaluate short-term retention (2 weeks; pin fixation vs. press-fit and fibrin fixation) and long-term repair (8 months; scaffold vs. microfracture), respectively. RESULTS: For the retention study, press-fit and fibrin fixation resulted in short-term scaffold dislodgment (n = 2 each), whereas pin fixation retained all scaffolds that were implanted (n = 6). Pin fixation did not cause any damage to the opposing patellar surface, and only minor changes in the subchondral bone were observed. For long-term repair, no differences were observed between microfracture and scaffold groups, in terms of second-look arthroscopy and indentation testing. On closer visualization with micro computed tomography and histology, a high degree of variability was observed between animals with regard to subchondral bone changes and cartilage repair quality, yet each Scaffold repair displayed similar properties to its matched microfracture control. CONCLUSIONS: In this study, pin fixation did not cause adverse events in either the short- or the long-term relative to controls, indicating that pin fixation successfully retained scaffolds within defects without inhibiting repair.
OBJECTIVE: Cartilage repair strategies have seen improvement in recent years, especially with the use of scaffolds that serve as a template for cartilage formation. However, current fixation strategies are inconsistent with regards to retention, may be technically challenging, or may damage adjacent tissues or the implant itself. Therefore, the goal of this study was to evaluate the retention and repair potential of cartilage scaffolds fixed with an easy-to-implement bioresorbable pin. DESIGN: Electrospun hyaluronic acid scaffolds were implanted into trochlear groove defects in 3 juvenile and 3 adult pigs to evaluate short-term retention (2 weeks; pin fixation vs. press-fit and fibrin fixation) and long-term repair (8 months; scaffold vs. microfracture), respectively. RESULTS: For the retention study, press-fit and fibrin fixation resulted in short-term scaffold dislodgment (n = 2 each), whereas pin fixation retained all scaffolds that were implanted (n = 6). Pin fixation did not cause any damage to the opposing patellar surface, and only minor changes in the subchondral bone were observed. For long-term repair, no differences were observed between microfracture and scaffold groups, in terms of second-look arthroscopy and indentation testing. On closer visualization with micro computed tomography and histology, a high degree of variability was observed between animals with regard to subchondral bone changes and cartilage repair quality, yet each Scaffold repair displayed similar properties to its matched microfracture control. CONCLUSIONS: In this study, pin fixation did not cause adverse events in either the short- or the long-term relative to controls, indicating that pin fixation successfully retained scaffolds within defects without inhibiting repair.
Entities:
Keywords:
animal model; cartilage; fixation; microfracture; subchondral bone
Authors: Guilherme C Gracitelli; Vinícius Y Moraes; Carlos Es Franciozi; Marcus V Luzo; João Carlos Belloti Journal: Cochrane Database Syst Rev Date: 2016-09-03
Authors: Iris L Kim; Christian G Pfeifer; Matthew B Fisher; Vishal Saxena; Gregory R Meloni; Mi Y Kwon; Minwook Kim; David R Steinberg; Robert L Mauck; Jason A Burdick Journal: Tissue Eng Part A Date: 2015-09-24 Impact factor: 3.845
Authors: Hannah M Zlotnick; Ryan C Locke; Sanjana Hemdev; Brendan D Stoeckl; Sachin Gupta; Ana P Peredo; David R Steinberg; James L Carey; Daeyeon Lee; George R Dodge; Robert L Mauck Journal: Biofabrication Date: 2022-07-05 Impact factor: 11.061
Authors: David C Browe; Ross Burdis; Pedro J Díaz-Payno; Fiona E Freeman; Jessica M Nulty; Conor T Buckley; Pieter A J Brama; Daniel J Kelly Journal: Mater Today Bio Date: 2022-07-05
Authors: H M Zlotnick; R C Locke; B D Stoeckl; J M Patel; S Gupta; K D Browne; J Koh; J L Carey; R L Mauck Journal: Eur Cell Mater Date: 2021-05-19 Impact factor: 3.942