| Literature DB >> 33034277 |
Yurday Ozdemir1, Ibrahim Acibuci1, Ugur Selek2,3, Erkan Topkan1.
Abstract
BACKGROUND: This preliminary simulation study aimed to compare the dosimetric outcomes of carotid arteries (CAs) and pharyngeal constrictor muscle (PCM) in patients with T1N0M0 glottic carcinoma undergoing helical tomotherapy-intensity modulated radiotherapy (HT-IMRT) and 3-dimensional conformal radiotherapy (3D-CRT) plans.Entities:
Keywords: 3D-conformal radiotherapy; carotid arteries; glottic carcinoma; helical-tomotherapy; pharyngeal constrictor muscle
Year: 2020 PMID: 33034277 PMCID: PMC7549151 DOI: 10.1177/1533033820956989
Source DB: PubMed Journal: Technol Cancer Res Treat ISSN: 1533-0338
Figure 1.Delineation of target and organ at risk volumes.
Figure 2.Isodose curves on an axial slice for a representative case planned with (A) helical tomotherapy-intensity-modulated radiotherapy plan. (B) 3D- conformal radiotherapy plan. dose-volume histogram of the planning target volume and organ at risk volumes for 2 treatment modalities (C) helical tomotherapy-intensity-modulated radiotherapy. (D) 3D- conformal radiotherapy. abbreviations: RCA, right carotid artery; LCA, left carotid artery; PCM, pharyngeal constrictor muscle; SC, spinal cord; PTV, planning target volume.
Comparisons of Dosimetric Characteristics for 2 Treatment Techniques.
| Parameter | HT-IMRT | 3D-CRT | p-value |
|---|---|---|---|
|
| |||
| Mean dose, Gy (range) | 20.7 (9.2-27.6) | 48.7 (36.2-65.7) | <0.001 |
| Dmax, Gy (range) | 53.6 (32.6-67.2) | 67.4 (62.4-70.4) | 0.003 |
| V30 (%) | 25.0 (0.6-47.5) | 77.6 (55.8-100) | <0.001 |
| V40 (%) | 8.0 (0.0-15.6) | 74.6 (52.8-100) | <0.001 |
| V50 (%) | 2.0 (0.0-5.3) | 70.0 (47.8-98.1) | <0.001 |
|
| |||
| Mean dose, Gy (range) | 21.5 (11-30.5) | 50.5 (31.5-66.5) | <0.001 |
| Dmax, Gy (range) | 52.0 (38.3-64.5) | 67.7 (65-70.5) | <0.001 |
| V30 (%) | 27.1 (3.3-52.7) | 80.3 (49.6-100) | <0.001 |
| V40 (%) | 7.9 (0.0-20.5) | 71.9 (6.4-100) | <0.001 |
| V50 (%) | 1.2 (0-4.9) | 71.6 (42.4-100) | <0.001 |
|
| |||
| Mean dose, Gy (range) | 49.6 (35.0-57.3) | 62.5 (55.3-65.1) | <0.001 |
| Dmax, Gy (range) | 65.6 (59.6-67.5) | 66.0 (64.3-68.0) | 0.513 |
|
| |||
| Dmax, Gy (range) | 69.1 (67.2-71.3) | 69.1 (67.4-70.2) | 0.864 |
| D95% | 64.7 (64.4-66.7) | 63.5 (62.4-64.2) | <0.001 |
| V95% | 99.3 (97.3-100.0) | 100.0 (98.5-100.0) | 0.13 |
| V100% | 95.2 (95.0-95.5) | 84.5 (72.0-93.3) | <0.001 |
|
| |||
| Dmax, Gy (range) | 31.4 (21.1-38.3) | 4.8 (1.9-19.4) | <0.001 |
Abbreviations: Gy, gray; HT-IMRT, helical tomotherapy-intensity modulated radiotherapy; 3DCRT, 3 dimensional conformal radiotherapy; PCM, pharyngeal constrictor muscle; PTV, planning target volume; Dmax, maximum dose; VD, the percentage of the organ volume that received D Gy or more; DX, dose received by the X% of the volume.