OBJECTIVE: This study analyzed the effect of ionizing radiation on bone microarchitecture and biomechanical properties in the bone tissue surrounding a dental implant.Entities:
Mesh:
Substances:
Year: 2020 PMID: 32997090 PMCID: PMC7521423 DOI: 10.1590/1678-7757-2020-0191
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Figure 1Implant installation on the rabbit tibia. A - Two implants installed on the right tibia with dissection of soft tissue and periosteum. B - Schematic 3D model of transverse tibia section showing the implant installed in cortical bone
Figure 2Dynamic Indentation test. A - Indentation moment in metallic device with the tibia embedded in polyester resin. B - Two indentations in a cortical bone close to the implant surface
Mean and standard deviation values of cortical volume (Ct.V), cortical thickness (Ct.Th), and porosity (Ct.Po) measured by micro-CT analysis for nonirradiated and irradiated group close and distant from the implant surface
| Groups | Ct.V (mm3) | Ct.Th (mm) | Ct.Po (%) | |
|---|---|---|---|---|
| Nonirradiated animals group | 6.9±0.3A | 0.30±0.06A | 65.9±1.4A | |
| Irradiated animal group | Measured distant to the implant surface | 6.5±0.3B | 0.31±0.03A | 68.4±1.1B |
| Measured close to the implant surface | 6.1±0.3C | 0.33±0.03A | 71.9±1.7C | |
Superscript letters represent significant difference within each morphological parameter, defined by Tukey test (P<0.05).
Mean and standard deviation values of elastic modulus and Vickers hardness measured by dynamic indentation test for non-irradiated group and irradiated group close and distant from the implant surface
| Groups | Elastic modulus (GPa) | Vickers hardness (N/mm2) | |
|---|---|---|---|
| Nonirradiated animals group | 20.8±3.2A | 115.9±32.5A | |
| Irradiated animals group | Measured distant to the implant surface | 18.3±2.5B | 91.5±32.0B |
| Measured close to the implant surface | 16.1±2.5C | 69.7±27.2C | |
Superscript letters represent significant difference within each mechanical property, defined by Student’s t-test (P<0.05).
Mean and standard deviation values of failure load, displacement up to the failure point and interface stiffness measured by pull-out test for nonirradiated and irradiated group
| Groups | Failure load (N) | Displacement (mm) | Stiffness (N/mm) |
|---|---|---|---|
| Nonirradiated animals group | 406.7±51.8A | 1.67±0.74A | 339.8±89.4A |
| Irradiated implants group | 321.4±89.4B | 0.79±0.20B | 287.9±64.6B |
Superscript letters represent significant difference within each mechanical parameter, defined by Tukey test (P<0.05).