Literature DB >> 32979366

An immunosensor for the determination of carcinoembryonic antigen by Surface Plasmon Resonance imaging.

Beata Szymanska1, Zenon Lukaszewski2, Kinga Hermanowicz-Szamatowicz3, Ewa Gorodkiewicz4.   

Abstract

Carcinoembryonic antigen (CEA) is one of the biomarkers most commonly used to determine tumor activity. In this work, a Surface Plasmon Resonance imaging (SPRi) immunosensor was developed. The immunosensor consists of a cysteamine linker attached to a gold chip and mouse monoclonal anti-CEA antibody bonded by the "EDC/NHS protocol". The formation of successive immunosensor layers was confirmed by AFM measurements. The concentration of the antibody was optimized. The linear response range of the developed immunosensor is between 0.40 and 20 ng mL-1, and it is suitable for CEA measurement in both blood cancer patients and healthy individuals. Only 3 μL of serum or plasma sample is required, and no preconcentration is used. The method has a precision of 2-16%, a recovery of 101-104% depending on CEA concentration, a detection limit of 0.12 ng mL-1 and a quantification limit of 0.40 ng mL-1. The method is selective (with respect to albumin, leptin, interleukin 6, metalloproteinase-1, metallopeptidase inhibitor 1 and CA 125/MUC16) and it was validated by comparison with the standard electrochemiluminescence method on a series of colorectal cancer blood samples. Published by Elsevier Inc.

Entities:  

Keywords:  Blood plasma; CEA; Colon cancer; SPRi

Mesh:

Substances:

Year:  2020        PMID: 32979366     DOI: 10.1016/j.ab.2020.113964

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  4 in total

1.  Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi.

Authors:  Beata Szymanska; Zenon Lukaszewski; Lukasz Oldak; Beata Zelazowska-Rutkowska; Kinga Hermanowicz-Szamatowicz; Ewa Gorodkiewicz
Journal:  Biosensors (Basel)       Date:  2022-06-14

Review 2.  Surface Plasmon Resonance (SPR) Spectroscopy and Photonic Integrated Circuit (PIC) Biosensors: A Comparative Review.

Authors:  Patrick Steglich; Giulia Lecci; Andreas Mai
Journal:  Sensors (Basel)       Date:  2022-04-09       Impact factor: 3.847

3.  A Comparison of Various Chips Used for the Manufacture of Biosensors Applied in Non-Fluidic Array SPRi, Based on the Example of Determination of Cathepsin D.

Authors:  Pawel Falkowski; Piotr Mrozek; Piotr Miluski; Zenon Lukaszewski; Ewa Gorodkiewicz
Journal:  Biosensors (Basel)       Date:  2021-12-31

Review 4.  A Review of Biosensors for Detecting Tumor Markers in Breast Cancer.

Authors:  Rui Hong; Hongyu Sun; Dujuan Li; Weihuang Yang; Kai Fan; Chaoran Liu; Linxi Dong; Gaofeng Wang
Journal:  Life (Basel)       Date:  2022-02-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.