Literature DB >> 32975704

Effect of heat application on the physical properties and chemical structure of calcium silicate-based sealers.

Hacer Aksel1, Steven Makowka2, Fatima Bosaid3, Mary Grace Guardian4, Debanjan Sarkar5, Adham A Azim6.   

Abstract

OBJECTIVE: To determine the effect of heat application on the setting and chemical properties of HiFlow BC Sealer and compare to other calcium silicate (CSBS) and epoxy resin-based root canal sealers.
MATERIALS AND METHODS: AH Plus, BioRoot RCS (BioRoot), Endosequence BC (Endosequence), and HiFlow BC (HiFlow) sealers were placed at 37 °C or subjected to heat at 200 °C for 10 or 30 s, followed by incubation at 37 °C in a humidified incubator during experiments. Setting time, viscosity, and flow were assessed, and changes in chemical structure were evaluated using the Fourier-transform infrared spectroscopy (FTIR). Thermogravimetric analysis was also used to evaluate the weight change (%) of the sealers upon heating from room temperature to 37 °C or 200 °C at a rate of 20 °C/min. Data were analyzed using a two-way ANOVA with a Bonferroni post-hoc test (p = 0.05).
RESULTS: Application of heat extended the setting time for Endosequence and HiFlow but resulted in a faster setting of AH Plus and BioRoot. The highest flow and lower viscosity were observed in HiFlow at high temperature (p < 0.05), whereas the lowest flow with the highest viscosity and greatest weight loss were observed in BioRoot after heat application (p < 0.05). FTIR spectra demonstrated no changes to functional groups after heat application, except for the strong H-O-H absorption peak corresponding to water in BioRoot.
CONCLUSIONS: Endosequence and HiFlow showed similar chemical properties with a higher flow and lower viscosity in HiFlow after heat application. Heat application resulted in reduced flow, increased viscosity, and weight loss for BioRoot. The setting of AH Plus was fastened with heat, while its weight loss, viscosity, and flow characteristics were stable. CLINICAL RELEVANCE: HiFlow, Endosequence, and AH Plus can be all used with WVC obturation techniques. Heat application resulted in minor changes in their physical properties including setting time, flow, weight loss, and chemical properties, while BioRoot showed a significant amount of weight loss, increase in viscosity, and reduced flowability after heat application.

Entities:  

Keywords:  Calcium silicate; FTIR; Flow; Sealer; Setting time; Viscosity; Warm obturation

Year:  2020        PMID: 32975704     DOI: 10.1007/s00784-020-03586-w

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  30 in total

Review 1.  Calcium silicate bioactive cements: Biological perspectives and clinical applications.

Authors:  Carlo Prati; Maria Giovanna Gandolfi
Journal:  Dent Mater       Date:  2015-02-07       Impact factor: 5.304

2.  Filling root canals in three dimensions. 1967.

Authors:  Herbert Schilder
Journal:  J Endod       Date:  2006-04       Impact factor: 4.171

3.  Defining Endodontic Residents' Clinical Experiences: A National Survey.

Authors:  Jonathan D Blacher; Kamran E Safavi; Robert H Aseltine; Blythe M Kaufman
Journal:  J Dent Educ       Date:  2019-02-25       Impact factor: 2.264

4.  Antibiofilm activity, pH and solubility of endodontic sealers.

Authors:  N B Faria-Júnior; M Tanomaru-Filho; F L C V Berbert; J M Guerreiro-Tanomaru
Journal:  Int Endod J       Date:  2013-02-26       Impact factor: 5.264

5.  Chemical characterization and bioactivity of epoxy resin and Portland cement-based sealers with niobium and zirconium oxide radiopacifiers.

Authors:  Raqueli Viapiana; Juliane Maria Guerreiro-Tanomaru; Marco Antonio Hungaro-Duarte; Mário Tanomaru-Filho; Josette Camilleri
Journal:  Dent Mater       Date:  2014-06-18       Impact factor: 5.304

6.  Investigation of chemical changes in sealers during application of the warm vertical compaction technique.

Authors:  R Viapiana; C A Baluci; M Tanomaru-Filho; J Camilleri
Journal:  Int Endod J       Date:  2014-03-20       Impact factor: 5.264

Review 7.  Are Premixed Calcium Silicate-based Endodontic Sealers Comparable to Conventional Materials? A Systematic Review of In Vitro Studies.

Authors:  Luiza Helena Silva Almeida; Rafael Ratto Moraes; Renata Dornelles Morgental; Fernanda Geraldo Pappen
Journal:  J Endod       Date:  2017-02-16       Impact factor: 4.171

8.  The Antimicrobial Effect of Bioceramic Sealer on an 8-week Matured Enterococcus faecalis Biofilm Attached to Root Canal Dentinal Surface.

Authors:  Sarah Bukhari; Bekir Karabucak
Journal:  J Endod       Date:  2019-05-31       Impact factor: 4.171

9.  Techniques and materials used by general dentists during endodontic treatment procedures: Findings from The National Dental Practice-Based Research Network.

Authors:  Paul D Eleazer; Gregg H Gilbert; Ellen Funkhouser; Gregg J Reams; Alan S Law; Paul L Benjamin
Journal:  J Am Dent Assoc       Date:  2015-11-06       Impact factor: 3.634

10.  Evaluation of calcium-releasing and apatite-forming abilities of fast-setting calcium silicate-based endodontic materials.

Authors:  L Han; S Kodama; T Okiji
Journal:  Int Endod J       Date:  2014-05-14       Impact factor: 5.264

View more
  3 in total

1.  Intratubular penetration ability in the canal perimeter using HiFlow bioceramic sealer with warm obturation techniques and single cone.

Authors:  Alberto Casino-Alegre; Susana Aranda-Verdú; Jose-Ignacio Zarzosa-López; Jorge Rubio-Climent; Eliseo Plasencia-Alcina; Antonio Pallarés-Sabater
Journal:  J Clin Exp Dent       Date:  2022-08-01

2.  Physico-Chemical Investigation of Endodontic Sealers Exposed to Simulated Intracanal Heat Application: Hydraulic Calcium Silicate-Based Sealers.

Authors:  David Donnermeyer; Magdalena Ibing; Sebastian Bürklein; Iris Weber; Maximilian P Reitze; Edgar Schäfer
Journal:  Materials (Basel)       Date:  2021-02-04       Impact factor: 3.623

3.  Intratubular penetration capacity of HiFlow bioceramic sealer used with warm obturation techniques and single cone: A confocal laser scanning microscopic study.

Authors:  Alberto Casino Alegre; Susana Aranda Verdú; José Ignacio Zarzosa López; Eliseo Plasencia Alcina; Jorge Rubio Climent; Antonio Pallarés Sabater
Journal:  Heliyon       Date:  2022-08-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.