Literature DB >> 24697552

Investigation of chemical changes in sealers during application of the warm vertical compaction technique.

R Viapiana1, C A Baluci, M Tanomaru-Filho, J Camilleri.   

Abstract

AIM: To assess (i) heat generated by pluggers during warm vertical compaction of gutta-percha and investigation of temperature changes on the external root surface during canal filling, and (ii) the chemical changes of root canal sealers induced by heat.
METHODOLOGY: Four sealers, namely AH Plus, MTA Plus and two other experimental sealers based on tricalcium silicate, were characterised. External temperatures generated on the root surface during warm vertical compaction of gutta-percha with different sealers inside the root canal were monitored using an infrared thermography camera. Chemical changes induced by heating the sealers were assessed by Fourier transform infrared (FT-IR) spectroscopy.
RESULTS: MTA Plus and the experimental sealers were composed of a cement and radiopacifier, with epoxy resin or a water-soluble polymer as dispersant, whilst AH Plus was epoxy resin-based. The heat generated at the tips of the continuous wave pluggers was found to be lower than the temperature set and indicated on the device LCD display. The sealers reduced the heat generated on the external root surfaces during the heating phase. AH Plus sustained changes to its chemical structure after exposure to heat, whilst the other sealers were unaffected.
CONCLUSIONS: The temperatures recorded at the tips of continuous wave pluggers varied with their taper and were lower than the temperature set on the System B LCD display. Root canal sealers reduced the dissipation of heat generated during warm vertical compaction, with the temperature at the external root surface maintained at 37-41 °C, a temperature below that is necessary to cause irreversible damage to bone and periodontium. The use of AH Plus sealer during warm vertical compaction techniques results in chemical changes in the sealer. The effect on sealer properties needs to be further investigated.
© 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  AH Plus; MTA Plus; System B; characterisation; root canal obturation; root canal sealers

Mesh:

Substances:

Year:  2014        PMID: 24697552     DOI: 10.1111/iej.12271

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  9 in total

1.  Model assessing thermal changes during high temperature root canal irrigation.

Authors:  Analise Bartolo; Edmond Koyess; Josette Camilleri; Christopher Micallef
Journal:  Healthc Technol Lett       Date:  2016-08-05

2.  Microstructural composition, ion release, and bioactive potential of new premixed calcium silicate-based endodontic sealers indicated for warm vertical compaction technique.

Authors:  J L Sanz; S López-García; A Lozano; M P Pecci-Lloret; C Llena; J Guerrero-Gironés; F J Rodríguez-Lozano; L Forner
Journal:  Clin Oral Investig       Date:  2020-07-10       Impact factor: 3.573

3.  Effect of heat application on the physical properties and chemical structure of calcium silicate-based sealers.

Authors:  Hacer Aksel; Steven Makowka; Fatima Bosaid; Mary Grace Guardian; Debanjan Sarkar; Adham A Azim
Journal:  Clin Oral Investig       Date:  2020-09-25       Impact factor: 3.573

4.  A comparative study of dentinal tubule penetration and the retreatability of EndoSequence BC Sealer HiFlow, iRoot SP, and AH Plus with different obturation techniques.

Authors:  Ruiqi Yang; Jun Tian; Xiangya Huang; Shuxiang Lei; Yanling Cai; Zhezhen Xu; Xi Wei
Journal:  Clin Oral Investig       Date:  2021-02-26       Impact factor: 3.573

Review 5.  Genotoxicity, Bioactivity and Clinical Properties of Calcium Silicate Based Sealers: A Literature Review.

Authors:  Farnaz Jafari; Sanaz Jafari; Paria Etesamnia
Journal:  Iran Endod J       Date:  2017

6.  Physico-Chemical Investigation of Endodontic Sealers Exposed to Simulated Intracanal Heat Application: Hydraulic Calcium Silicate-Based Sealers.

Authors:  David Donnermeyer; Magdalena Ibing; Sebastian Bürklein; Iris Weber; Maximilian P Reitze; Edgar Schäfer
Journal:  Materials (Basel)       Date:  2021-02-04       Impact factor: 3.623

Review 7.  Retrievability of bioceramic-based sealers in comparison with epoxy resin-based sealer assessed using microcomputed tomography: A systematic review of laboratory-based studies.

Authors:  Buvaneshwari Arul; Aswathi Varghese; Anisha Mishra; Subashini Elango; Sairathna Padmanaban; Velmurugan Natanasabapathy
Journal:  J Conserv Dent       Date:  2022-03-07

8.  In vitro study of dentinal tubule penetration and filling quality of bioceramic sealer.

Authors:  Yahui Wang; Siyi Liu; Yanmei Dong
Journal:  PLoS One       Date:  2018-02-01       Impact factor: 3.240

9.  Plugger temperature of cordless heat carriers according to the time elapsed.

Authors:  Hoon-Sang Chang; Se-Hee Park; Kyung-Mo Cho; Jin-Woo Kim
Journal:  Restor Dent Endod       Date:  2018-02-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.