Literature DB >> 32970848

Development of fast multi-slice apparent T1 mapping for improved arterial spin labeling MRI measurement of cerebral blood flow.

Yang Ji1, Dongshuang Lu1, Yinghua Jiang2, Xiaoying Wang2, Yuguang Meng3, Phillip Zhe Sun1,3,4.   

Abstract

PURPOSE: To develop fast multi-slice apparent T1 (T1app ) mapping for accurate cerebral blood flow (CBF) quantification with arterial spin labeling (ASL) MRI.
METHODS: Fast multi-slice T1app was measured using a modified inversion recovery echo planar imaging (EPI) sequence with simultaneous application of ASL tagging radiofrequency (RF) and gradient pulses. The fast multi-slice T1app measurement was compared with the single-slice T1app imaging approach, repeated per slice. CBF was assessed in healthy adult Wistar rats (N = 5) and rats with acute stroke 24 hours after a transient middle cerebral artery occlusion (N = 5).
RESULTS: The fast multi-slice T1app measurement was in good agreement with that of a single-slice T1app imaging approach (Lin's concordance correlation coefficient = 0.92). CBF calculated using T1app reasonably accounted for the finite labeling RF duration, whereas the routine T1 -normalized ASL MRI underestimated the CBF, particularly at short labeling durations. In acute stroke rats, the labeling time and the CBF difference (ΔCBF) between the contralateral normal area and the ischemic lesion were significantly correlated when using T1 -normalized perfusion calculation (R = 0.844, P = .035). In comparison, T1app -normalized ΔCBF had little labeling time dependence based on the linear regression equation of ΔCBF = -0.0247*τ + 1.579 mL/g/min (R = -0.352, P = .494).
CONCLUSIONS: Our study found fast multi-slice T1app imaging improves the accuracy and reproducibility of CBF measurement.
© 2020 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  apparent longitudinal relaxation time; arterial spin labeling; cerebral blood flow; magnetization transfer; stroke

Mesh:

Substances:

Year:  2020        PMID: 32970848      PMCID: PMC7718392          DOI: 10.1002/mrm.28510

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  41 in total

1.  Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: feasibility study.

Authors:  Jiongjiong Wang; Yan Zhang; Ronald L Wolf; Anne C Roc; David C Alsop; John A Detre
Journal:  Radiology       Date:  2005-02-16       Impact factor: 11.105

2.  Perfusion imaging with compensation for asymmetric magnetization transfer effects.

Authors:  J Pekar; P Jezzard; D A Roberts; J S Leigh; J A Frank; A C McLaughlin
Journal:  Magn Reson Med       Date:  1996-01       Impact factor: 4.668

3.  On the accuracy of T1 mapping: searching for common ground.

Authors:  Nikola Stikov; Mathieu Boudreau; Ives R Levesque; Christine L Tardif; Joëlle K Barral; G Bruce Pike
Journal:  Magn Reson Med       Date:  2014-02-27       Impact factor: 4.668

4.  Ultrafast CEST imaging.

Authors:  Jörg Döpfert; Moritz Zaiss; Christopher Witte; Leif Schröder
Journal:  J Magn Reson       Date:  2014-03-20       Impact factor: 2.229

5.  NMR measurement of perfusion using arterial spin labeling without saturation of macromolecular spins.

Authors:  W Zhang; A C Silva; D S Williams; A P Koretsky
Journal:  Magn Reson Med       Date:  1995-03       Impact factor: 4.668

6.  Spatiotemporal characteristics of postischemic hyperperfusion with respect to changes in T1, T2, diffusion, angiography, and blood-brain barrier permeability.

Authors:  Qiang Shen; Fang Du; Shiliang Huang; Timothy Q Duong
Journal:  J Cereb Blood Flow Metab       Date:  2011-05-04       Impact factor: 6.200

7.  Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo.

Authors:  S D Wolff; R S Balaban
Journal:  Magn Reson Med       Date:  1989-04       Impact factor: 4.668

8.  Regional variation of cerebral blood flow and arterial transit time in the normal and hypoperfused rat brain measured using continuous arterial spin labeling MRI.

Authors:  David L Thomas; Mark F Lythgoe; Louise van der Weerd; Roger J Ordidge; David G Gadian
Journal:  J Cereb Blood Flow Metab       Date:  2006-02       Impact factor: 6.200

Review 9.  Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia.

Authors:  David C Alsop; John A Detre; Xavier Golay; Matthias Günther; Jeroen Hendrikse; Luis Hernandez-Garcia; Hanzhang Lu; Bradley J MacIntosh; Laura M Parkes; Marion Smits; Matthias J P van Osch; Danny J J Wang; Eric C Wong; Greg Zaharchuk
Journal:  Magn Reson Med       Date:  2014-04-08       Impact factor: 4.668

10.  Modeling pulsed magnetization transfer.

Authors:  Sharon Portnoy; Greg J Stanisz
Journal:  Magn Reson Med       Date:  2007-07       Impact factor: 3.737

View more
  6 in total

1.  Consistent depiction of the acidic ischemic lesion with APT MRI-Dual RF power evaluation of pH-sensitive image in acute stroke.

Authors:  Phillip Zhe Sun
Journal:  Magn Reson Med       Date:  2021-09-30       Impact factor: 4.668

2.  Quasi-steady-state amide proton transfer (QUASS APT) MRI enhances pH-weighted imaging of acute stroke.

Authors:  Phillip Zhe Sun
Journal:  Magn Reson Med       Date:  2022-08-19       Impact factor: 3.737

3.  Quasi-steady-state chemical exchange saturation transfer (QUASS CEST) MRI analysis enables T1 normalized CEST quantification - Insight into T1 contribution to CEST measurement.

Authors:  Phillip Zhe Sun
Journal:  J Magn Reson       Date:  2021-06-08       Impact factor: 2.734

4.  Quasi-steady state chemical exchange saturation transfer (QUASS CEST) analysis-correction of the finite relaxation delay and saturation time for robust CEST measurement.

Authors:  Phillip Zhe Sun
Journal:  Magn Reson Med       Date:  2021-01-23       Impact factor: 3.737

5.  Quasi-steady-state CEST (QUASS CEST) solution improves the accuracy of CEST quantification: QUASS CEST MRI-based omega plot analysis.

Authors:  Phillip Zhe Sun
Journal:  Magn Reson Med       Date:  2021-03-10       Impact factor: 3.737

6.  Effects of red blood cells with reduced deformability on cerebral blood flow and vascular water transport: measurements in rats using time-resolved pulsed arterial spin labelling at 9.4 T.

Authors:  Adnan Bibic; Tea Sordia; Erik Henningsson; Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  Eur Radiol Exp       Date:  2021-12-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.