Literature DB >> 32950507

Accuracy of Artificial Intelligence Formulas and Axial Length Adjustments for Highly Myopic Eyes.

Huanhuan Cheng1, Li Wang2, Jack X Kane3, Jianbing Li4, Liangping Liu4, Mingxing Wu5.   

Abstract

PURPOSE: To compare the accuracy of artificial intelligence formulas (Kane formula and Radial Basis Function [RBF] 2.0) and other formulas, including the original and modified Wang-Koch (MWK) adjustment formulas for Holladay 1 (H1-MWK) and SRK/T (SRK/T-WK and SRK/T-MWK), the Barrett Universal II (BUII), the emmetropia-verifying optical (EVO), and the Haigis equation in highly myopic eyes.
DESIGN: Retrospective consecutive case-series study.
METHODS: A total of 370 eyes with an axial length (AL) ≥26.0 mm of 370 patients were enrolled, and subgroup analyses was performed based on ALs. The median absolute error (MedAE), the percentages of eyes with hyperopic outcome and within ±0.25 diopters (D), ±0.50 D, and ±1.00 D of prediction error were determined.
RESULTS: Overall, the Kane equation had the lowest MedAE (0.26 D), followed by H1-WK (0.27 D) and H1-MWK (0.28 D). There were no significant differences in MedAE among the Kane equation, the RBF 2.0, the BUII, the H1-MWK, and the H1-WK, whereas the Kane equation had a significantly lower MedAE than EVO (P < .001), SRK/T-MWK (P = .001), SRK/T-WK (P = .006), and Haigis (P < .001). In extremely myopic eyes with an AL ≥30.0 mm (n = 115), the Kane equation had a significantly lower MedAE than the RBF 2.0 (P = .001), the EVO (P = .019), the BUII (P = .013), and the Haigis method (P = .005), whereas no significant differences were found among the Kane, H1-MWK, and H1-WK equations.
CONCLUSIONS: The Kane equation was comparable to RBF 2.0, BUII, H1-MWK, and H1-WK in highly myopic eyes and was better than RBF 2.0 and BUII in extremely myopic eyes. The Kane, H1-MWK, and H1-WK methods were equally accurate in eyes with high to extreme myopia.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 32950507     DOI: 10.1016/j.ajo.2020.09.019

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  8 in total

1.  Accuracy of new-generation intraocular lens calculation formulas in eyes with variations in predicted refraction.

Authors:  Pingjun Chang; Shuyi Qian; Yalan Wang; Siyan Li; Fuman Yang; Yiwen Hu; Zhuohan Liu; Yun-E Zhao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-08       Impact factor: 3.117

2.  Subfoveal scleral thickness is associated with peripheral retinal changes in high myopia in children and adolescents.

Authors:  Wenli Zhang; Tingkun Shi; Shirong Chen; Haoyu Chen
Journal:  Int Ophthalmol       Date:  2022-01-29       Impact factor: 2.031

3.  Assessment of the influence of keratometry on intraocular lens calculation formulas in long axial length eyes.

Authors:  Shengjie Yin; Chengyao Guo; Kunliang Qiu; Tsz Kin Ng; Yuancun Li; Yali Du; Bingyao Chen; Hongxi Wang; Mingzhi Zhang
Journal:  Int Ophthalmol       Date:  2022-09-03       Impact factor: 2.029

4.  Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes.

Authors:  Ling Wei; Kaiwen Cheng; Wenwen He; Xiangjia Zhu; Yi Lu
Journal:  Eye Vis (Lond)       Date:  2022-06-09

5.  Comparison of Formula-Specific Factors and Artificial Intelligence Formulas with Axial Length Adjustments in Bilateral Cataract Patients with Long Axial Length.

Authors:  Chuang Li; Mingwei Wang; Rui Feng; Feiyan Liang; Xialin Liu; Chang He; Shuxin Fan
Journal:  Ophthalmol Ther       Date:  2022-08-02

6.  Investigating the Prediction Accuracy of Recently Updated Intraocular Lens Power Formulas with Artificial Intelligence for High Myopia.

Authors:  Miki Omoto; Kaoruko Sugawara; Hidemasa Torii; Erisa Yotsukura; Sachiko Masui; Yuta Shigeno; Yasuyo Nishi; Kazuno Negishi
Journal:  J Clin Med       Date:  2022-08-18       Impact factor: 4.964

7.  Accuracy of Six Intraocular Lens Power Calculations in Eyes with Axial Lengths Greater than 28.0 mm.

Authors:  Majid Moshirfar; Kathryn M Durnford; Jenna L Jensen; Daniel P Beesley; Telyn S Peterson; Ines M Darquea; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  J Clin Med       Date:  2022-10-08       Impact factor: 4.964

8.  Correlating Kane formula with existing intraocular lens formulae for corneal curvatures and axial lengths.

Authors:  P Priji; Sajeev Cherian Jacob; Lavanya Kalikivayi; Venkataramana Kalikivayi
Journal:  Oman J Ophthalmol       Date:  2021-06-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.