Literature DB >> 36057757

Assessment of the influence of keratometry on intraocular lens calculation formulas in long axial length eyes.

Shengjie Yin1, Chengyao Guo1,2, Kunliang Qiu1, Tsz Kin Ng1,2,3, Yuancun Li1,2, Yali Du1, Bingyao Chen1, Hongxi Wang1,2, Mingzhi Zhang4.   

Abstract

PURPOSE: Hyperopic surprises tend to occur in axial myopic eyes and other factors including corneal curvature have rarely been analyzed in cataract surgery, especially in eyes with long axial length (≥ 26.0 mm). Thus, the purpose of our study was to evaluate the influence of keratometry on four different formulas (SRK/T, Barrett Universal II, Haigis and Olsen) in intraocular lens (IOL) power calculation for long eyes.
METHODS: Retrospective case series. A total of 180 eyes with axial length (AL) ≥ 26.0 mm were divided into 3 keratometry (K) groups: K ≤ 42.0 D (Flat), K ≥ 46.0 D (Steep), 42.0 < K < 46.0 D (Average), and all the eyes were underwent phacoemulsification cataract surgery with Rayner (Hove, UK) 920H IOL implantation. Prediction errors (PE) were compared between different formulas to assess the accuracy of different formulas. Multiple regression analysis was performed to investigate factors associated with the PE.
RESULTS: The mean absolute error was higher for all evaluated formulas in Steep group (ranging from 0.66 D to 1.02 D) than the Flat (0.34 D to 0.67 D) and Average groups (0.40 D to 0.74D). The median absolute errors predicted by Olsen formula were significantly lower than that predicted by Haigis formula (0.42 D versus 0.85 D in Steep and 0.29 D versus 0.69 D in Average) in Steep and Average groups (P = 0.012, P < 0.001, respectively). And the Olsen formula demonstrated equal accuracy to the Barrett II formula in Flat and Average groups. The predictability of the SRK/T formula was affected by the AL and K, while the predictability of Olsen and Haigis formulas was affected by the AL only.
CONCLUSIONS: Steep cornea has more influence on the accuracy of IOL power calculation than the other corneal shape in long eyes. Overall, both the Olsen and Barrett Universal II formulas are recommended in long eyes with unusual keratometry.
© 2022. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Axial length; Cataract surgery; Intraocular lens power calculation; Keratometry

Year:  2022        PMID: 36057757     DOI: 10.1007/s10792-022-02322-5

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.029


  31 in total

1.  Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm.

Authors:  Li Wang; Mariko Shirayama; Xingxuan Jack Ma; Thomas Kohnen; Douglas D Koch
Journal:  J Cataract Refract Surg       Date:  2011-11       Impact factor: 3.351

2.  Corneal topography and myopia. A cross-sectional study.

Authors:  L G Carney; J C Mainstone; B A Henderson
Journal:  Invest Ophthalmol Vis Sci       Date:  1997-02       Impact factor: 4.799

3.  Protocols for studies of intraocular lens formula accuracy.

Authors:  Kenneth J Hoffer; Jaime Aramberri; Wolfgang Haigis; Thomas Olsen; Giacomo Savini; H John Shammas; Stanley Bentow
Journal:  Am J Ophthalmol       Date:  2015-06-25       Impact factor: 5.258

4.  Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery.

Authors:  Giacomo Savini; Kenneth J Hoffer; Piero Barboni
Journal:  J Cataract Refract Surg       Date:  2015-04       Impact factor: 3.351

5.  Reply.

Authors:  Kenneth J Hoffer; Giacomo Savini
Journal:  Ophthalmology       Date:  2020-12-01       Impact factor: 12.079

Review 6.  Effect of Gender and Race on Ocular Biometry.

Authors:  Kenneth J Hoffer; Giacomo Savini
Journal:  Int Ophthalmol Clin       Date:  2017

7.  Effect of Axial Length Adjustment Methods on Intraocular Lens Power Calculation in Highly Myopic Eyes.

Authors:  Jiaqing Zhang; Xuhua Tan; Wei Wang; Guangyao Yang; Jingmin Xu; Xiaoting Ruan; Xiaoxun Gu; Lixia Luo
Journal:  Am J Ophthalmol       Date:  2020-03-12       Impact factor: 5.258

8.  Intraocular lens power calculation for eyes with high and low average keratometry readings: Comparison between various formulas.

Authors:  Olga Reitblat; Adi Levy; Guy Kleinmann; Tsahi T Lerman; Ehud I Assia
Journal:  J Cataract Refract Surg       Date:  2017-09       Impact factor: 3.351

Review 9.  Evidence-based guidelines for cataract surgery: guidelines based on data in the European Registry of Quality Outcomes for Cataract and Refractive Surgery database.

Authors:  Mats Lundström; Peter Barry; Ype Henry; Paul Rosen; Ulf Stenevi
Journal:  J Cataract Refract Surg       Date:  2012-04-26       Impact factor: 3.351

Review 10.  Role of the sclera in the development and pathological complications of myopia.

Authors:  Neville A McBrien; Alex Gentle
Journal:  Prog Retin Eye Res       Date:  2003-05       Impact factor: 21.198

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.