Shengjie Yin1, Chengyao Guo1,2, Kunliang Qiu1, Tsz Kin Ng1,2,3, Yuancun Li1,2, Yali Du1, Bingyao Chen1, Hongxi Wang1,2, Mingzhi Zhang4. 1. Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China. 2. Shantou University Medical College, Shantou, Guangdong, China. 3. Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Shatin, Hong Kong. 4. Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China. zmz@jsiec.org.
Abstract
PURPOSE: Hyperopic surprises tend to occur in axial myopic eyes and other factors including corneal curvature have rarely been analyzed in cataract surgery, especially in eyes with long axial length (≥ 26.0 mm). Thus, the purpose of our study was to evaluate the influence of keratometry on four different formulas (SRK/T, Barrett Universal II, Haigis and Olsen) in intraocular lens (IOL) power calculation for long eyes. METHODS: Retrospective case series. A total of 180 eyes with axial length (AL) ≥ 26.0 mm were divided into 3 keratometry (K) groups: K ≤ 42.0 D (Flat), K ≥ 46.0 D (Steep), 42.0 < K < 46.0 D (Average), and all the eyes were underwent phacoemulsification cataract surgery with Rayner (Hove, UK) 920H IOL implantation. Prediction errors (PE) were compared between different formulas to assess the accuracy of different formulas. Multiple regression analysis was performed to investigate factors associated with the PE. RESULTS: The mean absolute error was higher for all evaluated formulas in Steep group (ranging from 0.66 D to 1.02 D) than the Flat (0.34 D to 0.67 D) and Average groups (0.40 D to 0.74D). The median absolute errors predicted by Olsen formula were significantly lower than that predicted by Haigis formula (0.42 D versus 0.85 D in Steep and 0.29 D versus 0.69 D in Average) in Steep and Average groups (P = 0.012, P < 0.001, respectively). And the Olsen formula demonstrated equal accuracy to the Barrett II formula in Flat and Average groups. The predictability of the SRK/T formula was affected by the AL and K, while the predictability of Olsen and Haigis formulas was affected by the AL only. CONCLUSIONS: Steep cornea has more influence on the accuracy of IOL power calculation than the other corneal shape in long eyes. Overall, both the Olsen and Barrett Universal II formulas are recommended in long eyes with unusual keratometry.
PURPOSE: Hyperopic surprises tend to occur in axial myopic eyes and other factors including corneal curvature have rarely been analyzed in cataract surgery, especially in eyes with long axial length (≥ 26.0 mm). Thus, the purpose of our study was to evaluate the influence of keratometry on four different formulas (SRK/T, Barrett Universal II, Haigis and Olsen) in intraocular lens (IOL) power calculation for long eyes. METHODS: Retrospective case series. A total of 180 eyes with axial length (AL) ≥ 26.0 mm were divided into 3 keratometry (K) groups: K ≤ 42.0 D (Flat), K ≥ 46.0 D (Steep), 42.0 < K < 46.0 D (Average), and all the eyes were underwent phacoemulsification cataract surgery with Rayner (Hove, UK) 920H IOL implantation. Prediction errors (PE) were compared between different formulas to assess the accuracy of different formulas. Multiple regression analysis was performed to investigate factors associated with the PE. RESULTS: The mean absolute error was higher for all evaluated formulas in Steep group (ranging from 0.66 D to 1.02 D) than the Flat (0.34 D to 0.67 D) and Average groups (0.40 D to 0.74D). The median absolute errors predicted by Olsen formula were significantly lower than that predicted by Haigis formula (0.42 D versus 0.85 D in Steep and 0.29 D versus 0.69 D in Average) in Steep and Average groups (P = 0.012, P < 0.001, respectively). And the Olsen formula demonstrated equal accuracy to the Barrett II formula in Flat and Average groups. The predictability of the SRK/T formula was affected by the AL and K, while the predictability of Olsen and Haigis formulas was affected by the AL only. CONCLUSIONS: Steep cornea has more influence on the accuracy of IOL power calculation than the other corneal shape in long eyes. Overall, both the Olsen and Barrett Universal II formulas are recommended in long eyes with unusual keratometry.
Authors: Li Wang; Mariko Shirayama; Xingxuan Jack Ma; Thomas Kohnen; Douglas D Koch Journal: J Cataract Refract Surg Date: 2011-11 Impact factor: 3.351
Authors: Kenneth J Hoffer; Jaime Aramberri; Wolfgang Haigis; Thomas Olsen; Giacomo Savini; H John Shammas; Stanley Bentow Journal: Am J Ophthalmol Date: 2015-06-25 Impact factor: 5.258