Literature DB >> 3294884

Evaluation of the syphilis Bio-EnzaBead assay for detection of treponemal antibody.

N M Burdash, K K Hinds, J A Finnerty, J P Manos.   

Abstract

An enzyme-linked immunosorbent assay for Treponema pallidum antibody (Syphilis Bio-EnzaBead Kit; Organon Teknika Corp., formerly Litton Bionetics, Kensington, Md.) was compared with the standard fluorescent treponemal antibody absorption test for syphilis (indirect fluorescent-antibody confirmatory test; Zeus Scientific Inc., Raritan, N.J.). Six hundred specimens tested in the rapid plasma Reagin card test (Hynson, Westcott and Dunning, Inc., Baltimore, Md.) and microhemagglutination assay for antibodies to T. pallidum (Ames Division, Miles Laboratories, Inc., Elkhart, Ind.) were used for comparison testing. One hundred and sixty-two specimens were from either persons with syphilis or persons whose history was unknown but who showed reactive serology, whereas 438 were from persons without syphilis. The reactivity of each serum by the Bio-EnzaBead test was determined visually and from optical density readings. Excellent reproducibility of visual readings was obtained; all results were within +/- 1 gradation of the expected readings in all 60 coded sera tested. Overall agreement between the Bio-EnzaBead and fluorescent treponemal antibody absorption test results was 96.3% when read visually and greater than or equal to 95.7% when using optical density readings. Our data indicate that Bio-EnzaBead results read at 405 nm and determined by using the mean antigen optical density reading of the nonreactive control plus 0.025 as the cutoff value provide an overall sensitivity and specificity of 93.0 and 98.6%, respectively, along with the best agreement with the fluorescent treponemal antibody absorption assay. Ease of performance and objectivity also contribute toward the acceptability of this assay as an alternative confirmatory test for syphilis.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3294884      PMCID: PMC266093          DOI: 10.1128/jcm.25.5.808-811.1987

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  Application of the enzyme-linked immunosorbent assay (ELISA) in the serodiagnosis of syphilis.

Authors:  J Veldkamp; A M Visser
Journal:  Br J Vener Dis       Date:  1975-08

2.  AN IMPROVED FTA TEST FOR SYPHILIS, THE ABSORPTION PROCEDURE (FTA-ABS).

Authors:  E F HUNTER; W E DEACON; P E MEYER
Journal:  Public Health Rep       Date:  1964-05       Impact factor: 2.792

3.  Evaluation of an enzyme-linked immunosorbent assay for treponemal antibody.

Authors:  R W Stevens; M E Schmitt
Journal:  J Clin Microbiol       Date:  1985-03       Impact factor: 5.948

4.  Reactivity of microhemagglutination, fluorescent treponemal antibody absorption, Venereal Disease Research Laboratory, and rapid plasma reagin tests in primary syphilis.

Authors:  T W Huber; S Storms; P Young; L E Phillips; T E Rogers; D G Moore; R P Williams
Journal:  J Clin Microbiol       Date:  1983-03       Impact factor: 5.948

5.  Evaluation of the microenzyme-linked immunosorbent assay with Treponema pallidum antigen.

Authors:  V Pope; E F Hunter; J C Feeley
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

  5 in total
  5 in total

Review 1.  Laboratory techniques in the diagnosis of syphilis: a review.

Authors:  J J van der Sluis
Journal:  Genitourin Med       Date:  1992-12

2.  Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various stages of syphilis.

Authors:  A Ebel; L Bachelart; J M Alonso
Journal:  J Clin Microbiol       Date:  1998-02       Impact factor: 5.948

3.  Evaluation of the Captia enzyme immunoassays for detection of immunoglobulins G and M to Treponema pallidum in syphilis.

Authors:  J C Lefevre; M A Bertrand; R Bauriaud
Journal:  J Clin Microbiol       Date:  1990-08       Impact factor: 5.948

Review 4.  Laboratory diagnosis and interpretation of tests for syphilis.

Authors:  S A Larsen; B M Steiner; A H Rudolph
Journal:  Clin Microbiol Rev       Date:  1995-01       Impact factor: 26.132

5.  Evaluation of immunoglobulin G enzyme immunoassay for serodiagnosis of yaws.

Authors:  J L Backhouse; B J Hudson
Journal:  J Clin Microbiol       Date:  1995-07       Impact factor: 5.948

  5 in total