Literature DB >> 32946269

Novel noninvasive estimation of mixed venous oxygen saturation by echocardiography and expired gas analysis.

Takeshi Onoue1, Mai Iwataki1, Masaru Araki1, Jun Akashi1, Tetsuji Kitano1, Yosuke Nabeshima1, Soshi Hei1, Yasufumi Nagata1, Atsushi Hayashi1, Yuki Tsuda1, Shinjo Sonoda1, Yoshihisa Fujino2, Robert A Levine3, Yutaka Otsuji1.   

Abstract

Mixed venous oxygen (O2) saturation ([Formula: see text]) is an important measure for evaluating the sufficiency of cardiac output (CO) relative to whole body O2 consumption (V̇o2), while clinical use is limited to the required invasive catheterization. According to Fick's equation, V̇o2 (mL/min) = CO (L/min) × Hb (g/dL) × 1.36 (mL/g) × ([Formula: see text] - [Formula: see text])/10 (Hb = hemoglobin concentration, [Formula: see text] = arterial blood O2 saturation). Because V̇o2, CO, Hb, and [Formula: see text] can be measured noninvasively with expired gas analysis, echocardiography, a simple blood test, and percutaneous O2 saturation, respectively, [Formula: see text] can be calculated noninvasively. We hypothesized that noninvasively calculated [Formula: see text] shows a significant correlation and agrees well with invasively measured [Formula: see text]. In 47 patients (29 men; mean age, 70 ± 12 yr) who underwent right heart catheterization, [Formula: see text] was directly measured by sampling pulmonary artery blood. Noninvasively calculated [Formula: see text] was also obtained by the method described above. The calculated [Formula: see text] was significantly correlated with the measured [Formula: see text] (r = 0.79, P < 0.001) and was significantly smaller than the measured [Formula: see text] (70 ± 5.1 vs. 72.1 ± 4.9%, P < 0.001). Bias at [Formula: see text] was -2.2% (95% confidence interval, -3.2 to -1.1%) with limits of agreement from -9.5 to 5.2%, demonstrating acceptable agreement. The optimal cutoff value of calculated [Formula: see text] was 69% for reduced measured [Formula: see text] < 70% with an area under the curve of 0.94. Reduced calculated [Formula: see text] < 69% indicated a sensitivity of 92.9% and a specificity of 90.9% for reduced measured [Formula: see text] < 70%. Noninvasive [Formula: see text] calculated from echocardiography, expired gas analysis, percutaneous arterial blood O2 saturation, and hemoglobin level significantly correlated and agreed well with direct [Formula: see text] measured by catheterization. This novel method allows for practical evaluation of [Formula: see text] to assess the sufficiency of CO according to whole body metabolism.NEW & NOTEWORTHY Clinical use of mixed venous oxygen saturation ([Formula: see text]) is limited to the required invasive procedure. With Fick's equation, expired gas analysis, echocardiography, simple blood tests, and percutaneous oxygen saturation, [Formula: see text] can be calculated noninvasively. We hypothesized that noninvasively calculated [Formula: see text] shows a significant correlation and agrees well with invasively measured [Formula: see text]. The present study examined the relationship between measured [Formula: see text] and calculated [Formula: see text] in patients who underwent right heart catheterization and demonstrated acceptable agreement. This novel method can expand the indication of evaluating [Formula: see text].

Entities:  

Keywords:  echocardiography; heart failure; mixed venous oxygen saturation

Mesh:

Substances:

Year:  2020        PMID: 32946269      PMCID: PMC8083080          DOI: 10.1152/ajpheart.00429.2020

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  39 in total

1.  Early goal-directed therapy in the treatment of severe sepsis and septic shock.

Authors:  E Rivers; B Nguyen; S Havstad; J Ressler; A Muzzin; B Knoblich; E Peterson; M Tomlanovich
Journal:  N Engl J Med       Date:  2001-11-08       Impact factor: 91.245

2.  Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation.

Authors:  J C Berridge
Journal:  Br J Anaesth       Date:  1992-10       Impact factor: 9.166

3.  Predictive factors for usefulness of fiberoptic pulmonary artery catheter for continuous oxygen saturation in mixed venous blood monitoring in cardiac surgery.

Authors:  C Vedrinne; O Bastien; R De Varax; P Blanc; P G Durand; B Du Grès; H Bouvier; C Saroul; J J Lehot
Journal:  Anesth Analg       Date:  1997-07       Impact factor: 5.108

4.  Statistical considerations in reporting cardiovascular research.

Authors:  Merry L Lindsey; Gillian A Gray; Susan K Wood; Douglas Curran-Everett
Journal:  Am J Physiol Heart Circ Physiol       Date:  2018-07-20       Impact factor: 4.733

5.  Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging.

Authors:  Sherif F Nagueh; Otto A Smiseth; Christopher P Appleton; Benjamin F Byrd; Hisham Dokainish; Thor Edvardsen; Frank A Flachskampf; Thierry C Gillebert; Allan L Klein; Patrizio Lancellotti; Paolo Marino; Jae K Oh; Bogdan Alexandru Popescu; Alan D Waggoner
Journal:  J Am Soc Echocardiogr       Date:  2016-04       Impact factor: 5.251

6.  Assessment of oxygen-consumption by use of reverse Fick-principle and indirect calorimetry in critically ill patients.

Authors:  B Schneeweiss; W Druml; W Graninger; G Grimm; G Kleinberger; K Lenz; A Laggner
Journal:  Clin Nutr       Date:  1989-04       Impact factor: 7.324

Review 7.  Medical therapy of acute myocardial infarction by application of hemodynamic subsets (first of two parts).

Authors:  J S Forrester; G Diamond; K Chatterjee; H J Swan
Journal:  N Engl J Med       Date:  1976-12-09       Impact factor: 91.245

8.  Comparison of Minimally and More Invasive Methods of Determining Mixed Venous Oxygen Saturation.

Authors:  Marli Smit; Andrew I Levin; Johan F Coetzee
Journal:  J Cardiothorac Vasc Anesth       Date:  2015-09-25       Impact factor: 2.628

9.  Hemodynamic variables related to outcome in septic shock.

Authors:  Marjut Varpula; Minna Tallgren; Katri Saukkonen; Liisa-Maria Voipio-Pulkki; Ville Pettilä
Journal:  Intensive Care Med       Date:  2005-06-23       Impact factor: 17.440

10.  Guideline from Japanese Society of Echocardiography: 2018 focused update incorporated into Guidance for the Management and Maintenance of Echocardiography Equipment.

Authors:  Masao Daimon; Makoto Akaishi; Toshihiko Asanuma; Shuji Hashimoto; Chisato Izumi; Shiro Iwanaga; Hiroya Kawai; Hiroyuki Toide; Akihiro Hayashida; Hirotsugu Yamada; Mitsushige Murata; Yutaka Hirano; Kengo Suzuki; Satoshi Nakatani
Journal:  J Echocardiogr       Date:  2018-01-23
View more
  1 in total

1.  Risk prediction in pulmonary hypertension due to chronic heart failure: incremental prognostic value of pulmonary hemodynamics.

Authors:  Ruilin Quan; Shian Huang; Lingpin Pang; Jieyan Shen; Weifeng Wu; Fangming Tang; Xiulong Zhu; Weiqing Su; Jingzhi Sun; Zaixin Yu; Lemin Wang; Xianyang Zhu; Changming Xiong; Jianguo He
Journal:  BMC Cardiovasc Disord       Date:  2022-02-16       Impact factor: 2.298

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.