Literature DB >> 1419454

Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation.

J C Berridge1.   

Abstract

The influence of cardiac output on the correlation between central venous oxygen saturation and mixed venous oxygen saturation was assessed in 51 patients who had both a pulmonary artery catheter and separate central venous catheter in situ. Seventy-six paired samples were taken from the catheters and oxygen saturation measured immediately in a Ciba Corning 2500 Co-oximeter. Cardiac output was measured using a standard thermodilution technique. The data were separated into groups with low cardiac index (< 2.5 litre min-1 m-2; n = 20), medium cardiac index (2.5-4.0 litre min-1 m-2; n = 36) and high cardiac index (> 4.0 litre min-1 m-2; n = 20). The correlation coefficients of the three groups were: low cardiac index 0.95, medium cardiac index 0.88 and high cardiac index 0.95 (P < .001 for all three groups). All measurements were made before any x-ray and necessary repositioning of the central venous catheter. These results suggest that central venous oxygen saturation is a useful estimate of mixed venous oxygen saturation and that the influence of cardiac output on that estimate is minimal.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1419454     DOI: 10.1093/bja/69.4.409

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  12 in total

1.  Flurbiprofen axetil increases arterial oxygen partial pressure by decreasing intrapulmonary shunt in patients undergoing one-lung ventilation.

Authors:  Xiao-Qing Chai; Jun Ma; Yan-Hu Xie; Di Wang; Kun-Zhou Chen
Journal:  J Anesth       Date:  2015-08-14       Impact factor: 2.078

Review 2.  From system to organ to cell: oxygenation and perfusion measurement in anesthesia and critical care.

Authors:  Patrick Schober; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2012-03-22       Impact factor: 2.502

3.  Central venous oxygen saturation accurately reflects mixed venous oxygen saturation during laparotomy.

Authors:  Masayasu Nakayama; Noriaki Kanaya; Hideaki Tsuchida; Akiyoshi Namiki
Journal:  J Anesth       Date:  1996-12       Impact factor: 2.078

4.  Novel noninvasive estimation of mixed venous oxygen saturation by echocardiography and expired gas analysis.

Authors:  Takeshi Onoue; Mai Iwataki; Masaru Araki; Jun Akashi; Tetsuji Kitano; Yosuke Nabeshima; Soshi Hei; Yasufumi Nagata; Atsushi Hayashi; Yuki Tsuda; Shinjo Sonoda; Yoshihisa Fujino; Robert A Levine; Yutaka Otsuji
Journal:  Am J Physiol Heart Circ Physiol       Date:  2020-09-18       Impact factor: 4.733

5.  Intra-dialytic blood oxygen saturation (SO2): association with dialysis hypotension (the SOGLIA Study).

Authors:  E Mancini; C Perazzini; L Gesualdo; F Aucella; A Limido; F Scolari; S Savoldi; M Tramonti; L Corazza; M Atti; S Severi; P Bolasco; A Santoro
Journal:  J Nephrol       Date:  2016-08-29       Impact factor: 3.902

6.  Clinical impact of vasopressin infusion on hemodynamics, liver and renal function in pediatric patients.

Authors:  Nameet Jerath; Helena Frndova; Brian W McCrindle; Rebecca Gurofsky; Tilman Humpl
Journal:  Intensive Care Med       Date:  2008-03-19       Impact factor: 17.440

7.  Agreement of central venous saturation and mixed venous saturation in cardiac surgery patients.

Authors:  Michael Sander; Claudia D Spies; Achim Foer; Lisa Weymann; Jan Braun; Thomas Volk; Herko Grubitzsch; Christian von Heymann
Journal:  Intensive Care Med       Date:  2007-05-25       Impact factor: 17.440

8.  Should We Monitor ScVO(2) in Critically Ill Patients?

Authors:  Sophie Nebout; Romain Pirracchio
Journal:  Cardiol Res Pract       Date:  2011-09-21       Impact factor: 1.866

9.  Lactate concentration gradient from right atrium to pulmonary artery.

Authors:  Guillermo Gutierrez; Lakhmir S Chawla; Michael G Seneff; Nevin M Katz; Hasan Zia
Journal:  Crit Care       Date:  2005-06-10       Impact factor: 9.097

Review 10.  Equipment review: the success of early goal-directed therapy for septic shock prompts evaluation of current approaches for monitoring the adequacy of resuscitation.

Authors:  Scott R Gunn; Mitchell P Fink; Benjamin Wallace
Journal:  Crit Care       Date:  2005-05-27       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.