| Literature DB >> 32943838 |
Divya Narayanan1, Garrick Wallstrom2, John Rodriguez1, Donna Welch1, Matthew Chapin1, Paul Arrigg3,4, Rajkumar Patil1, Mark Abelson1,4,5.
Abstract
PURPOSE: Early detection and treatment of age-related macular degeneration require a clear understanding of the early progress of the disease. The purpose of this study was to investigate whether minimal macular ophthalmoscopic changes corresponded to changes in visual function.Entities:
Keywords: AMD; macula; visual function
Year: 2020 PMID: 32943838 PMCID: PMC7478363 DOI: 10.2147/OPTH.S260787
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Scaling Used to Define Groups with and without Minimal Macular Changes
| Group 0-A ( | Group 0-B ( |
|---|---|
| Best VA 20/25 or better AND no macular changes observed | Best VA 20/25 or better AND minimal macular changes such as mottling, pigment changes or small drusen (<63 µm observed) |
Figure 1Examples of fundus photos from two study eyes graded as 0-A (left; no minimal macular changes) and 0-B (right; with minimal macular changes). The black circle indicates the region in the macula where fundus retinal changes were observed.
Figure 2Images from same eyes as shown in Figure 1 under high magnification (A, B) and under gray scale (C, D) to better visualize the minimal macular changes seen in subject ID 042. The black circle indicates the region in the macula where fundus retinal changes were observed.
Mean ± SD of Visual Function Tests for 0-A and 0-B Groups
| Tests | Group 0-A ( | Group 0-B ( |
|---|---|---|
| ETDRS Distance VA Regular (LogMAR) | 0.0 ± 0.11 | 0.08 ± 0.12 |
| ETDRS Distance VA 2.0 (LogMAR) | 0.24 ± 0.15 | 0.29 ± 0.14 |
| Pell-Robson CS (log) | 1.75 ± 0.29 | 1.78 ± 0.17 |
| MN Read (wpm) | 214 ± 47.4 | 210 ± 64.7 |
| MN Read Reading Acuity (LogMAR) | 0.15 ± 0.18 | 0.07 ± 0.09 |
| VCF Threshold | 0.47 ± 0.25 | 0.43 ± 0.22 |
| High-Contrast High-Luminance (HCHL) Tablet Reading (wpm) | 176 ± 66.4 | 183 ± 32.3 |
| LowLuminance Tablet Reading (wpm) | 137 ± 71.8 | 151 ± 39.4 |
| LowContrast Tablet Reading (wpm) | 57 ± 42.6 | 61 ± 41.5 |
| Crowded Tablet Reading (wpm) | 182 ± 70.0 | 170 ± 46.7 |
| Pepper Tablet Reading (wpm) | 93 ± 39.4 | 97 ± 22.0 |
| Vanishing Optotypes Tablet Reading (wpm) | 159 ± 70.3 | 174 ± 43.9 |
Notes: Groups 0-A vs 0-B: p > 0.05 for all comparisons, with and without adjustment for ETDRS VA.