Literature DB >> 32943829

Combining kinematic alignment and medial stabilized design in total knee arthroplasty: Basic rationale and preliminary clinical evidences.

Salvatore Risitano1,2, Luigi Sabatini3, Luca Barberis3, Federico Fusini3, Michele Malavolta4, Pier Francesco Indelli2.   

Abstract

Objective: kinematic alignment technique has been recently described as a new surgical procedure able to restore the patient specific physiological knee alignment; furthermore, new prosthesis, as medial stabilized (MS) third generation TKA, were designed to better reproduce the anatomical shape of the knee. In this prospective study, the authors evaluated early clinical improvement and radiological outcomes of patients having pre-operative small coronal limb deformity underwent TKA using a surgical technique combining a "restricted kinematic alignment" with medial stabilized polyethylene insert.
METHODS: Fifteen consecutive patients (8 female and 7 male) scheduled for a total knee replacement have been enrolled for this study and treated using a modern third generation knee implant with a medial congruent tibial polyethylene. Clinical improvements have been assessed pre-operatively and at 6 and 12 months Follow up (FU) using the Oxford knee Score (OKS)( Ishikawa et al., Jun. 2015) 12 the Knee Society Score (KSS)( Pinskerova and et al., Aug. 2004) 13 and Forgotten Joint Score (FJS) as patient reported outcomes measurement system (PROMs). A radiological evaluation was made by a single physician at 6 months.
RESULTS: Average improvement in OKS was from 20.2 (SD 5.5) pre-operatively to 41.3 (SD 2.1) at the final FU. KSS pain/motion improved with a mean score from 40.1 (SD 4.0) pre-op to 89.1 (SD 6.3) while KSS function improved with an average score from 51.0 (SD 6.2) pre-op to 81.8 (SD 8.4) showing good to excellent results in all the knee treated. The mean FJS at 6 months follow up was 75.1 (SD 4.2) improving to 79.3 (SD 3.3) at one year FU. Post-operative XR showing an average varus Hip-Knee-Ankle (HKA) angle of 178.8° (range from 176° to 182°, SD 2,3°); We found no statistically significant difference between pre-operative and post-operative HKA (p < 0,05).
CONCLUSION: The current authors assumed appropriate to combine a modern TKA implant designed replicating the anatomical shape of the native knee with a surgical technique able to better reproduce the physiological, patient specific, knee biomechanics. Our findings suggest that combining MS implant with KA technique may results in better short-term functional results, helping the patient to "forget" their replaced joint and restoring their pre-arthritic quality of life.
© 2020 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Kinematic alignment; Knee; Medial stabilized design; Restricted KA; TKA; Total knee arthroplasty

Year:  2020        PMID: 32943829      PMCID: PMC7479312          DOI: 10.1016/j.jor.2020.08.025

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  35 in total

Review 1.  Early Outcomes of Kinematic Alignment in Primary Total Knee Arthroplasty: A Meta-Analysis of the Literature.

Authors:  P Maxwell Courtney; Gwo-Chin Lee
Journal:  J Arthroplasty       Date:  2017-02-27       Impact factor: 4.757

2.  Roentgenographic analysis of patellofemoral congruence.

Authors:  A C Merchant; R L Mercer; R H Jacobsen; C R Cool
Journal:  J Bone Joint Surg Am       Date:  1974-10       Impact factor: 5.284

3.  Redefining knee replacement.

Authors:  P-A Vendittoli; W Blakeney
Journal:  Orthop Traumatol Surg Res       Date:  2017-09-06       Impact factor: 2.256

4.  The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis.

Authors:  C Rivière; F Iranpour; S Harris; E Auvinet; A Aframian; P Chabrand; J Cobb
Journal:  Orthop Traumatol Surg Res       Date:  2017-09-01       Impact factor: 2.256

5.  Intraoperative medial pivot affects deep knee flexion angle and patient-reported outcomes after total knee arthroplasty.

Authors:  Yusuke Nishio; Tomohiro Onodera; Yasuhiko Kasahara; Daisuke Takahashi; Norimasa Iwasaki; Tokifumi Majima
Journal:  J Arthroplasty       Date:  2013-08-17       Impact factor: 4.757

Review 6.  Kinematically Aligned Total Knee Arthroplasty or Mechanically Aligned Total Knee Arthroplasty.

Authors:  Tsuneari Takahashi; Juned Ansari; Hemant G Pandit
Journal:  J Knee Surg       Date:  2018-02-14       Impact factor: 2.757

7.  Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty.

Authors:  T Matsumoto; K Takayama; K Ishida; S Hayashi; S Hashimoto; R Kuroda
Journal:  Bone Joint J       Date:  2017-05       Impact factor: 5.082

Review 8.  Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty.

Authors:  Yong Seuk Lee; Stephen M Howell; Ye-Yeon Won; O-Sung Lee; Seung Hoon Lee; Hamed Vahedi; Seow Hui Teo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

Review 9.  Indication criteria for total hip or knee arthroplasty in osteoarthritis: a state-of-the-science overview.

Authors:  Maaike G J Gademan; Stefanie N Hofstede; Thea P M Vliet Vlieland; Rob G H H Nelissen; Perla J Marang-van de Mheen
Journal:  BMC Musculoskelet Disord       Date:  2016-11-09       Impact factor: 2.362

10.  Comparison of kinematic and mechanical alignment techniques in primary total knee arthroplasty: A meta-analysis.

Authors:  Jung-Ro Yoon; Seung-Beom Han; Min-Kyo Jee; Young-Soo Shin
Journal:  Medicine (Baltimore)       Date:  2017-09       Impact factor: 1.889

View more
  3 in total

Review 1.  Restricted kinematic alignment in primary total knee arthroplasty: A systematic review of radiographic and clinical data.

Authors:  Salvatore Risitano; Giorgio Cacciola; Luigi Sabatini; Marcello Capella; Francesco Bosco; Fortunato Giustra; Alessandro Massè; Raju Vaishya
Journal:  J Orthop       Date:  2022-07-02

2.  Similar migration for medial congruent and cruciate-retaining tibial components in an anatomic TKA system: a randomized controlled trial of 60 patients followed with RSA for 2 years.

Authors:  Albin Christensson; Magnus Tveit; Uldis Kesteris; Gunnar Flivik
Journal:  Acta Orthop       Date:  2022-01-03       Impact factor: 3.717

Review 3.  Clinical radiographic outcomes and survivorship of medial pivot design total knee arthroplasty: a systematic review of the literature.

Authors:  Mattia Alessio-Mazzola; Antonio Clemente; Antonio Russo; Peter Mertens; Giorgio Burastero; Matteo Formica; Lamberto Felli
Journal:  Arch Orthop Trauma Surg       Date:  2021-10-11       Impact factor: 2.928

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.