Literature DB >> 29444542

Kinematically Aligned Total Knee Arthroplasty or Mechanically Aligned Total Knee Arthroplasty.

Tsuneari Takahashi1,2, Juned Ansari3, Hemant G Pandit1.   

Abstract

Kinematically aligned total knee arthroplasty (KATKA) was developed to more anatomically align the knee prosthesis to restore the native alignment of the knee and promote physiological kinematics. Even though there are concerns with implant survival, and follow-up at 10 years or more after KATKA has not been reported, there is a negligible incidence of failure of a tibial component at 2 to 9 years. Early clinical results with this technique are encouraging and demonstrate better functional outcomes compared with mechanically aligned TKA (MATKA). The purpose of this study is to perform a systematic review and meta-analysis of the literature to determine whether there are any clinical differences between KATKA and MATKA. The authors conducted a systematic review of the English literature. Five randomized controlled trials (RCTs) which compared clinical outcomes of KATKA and MATKA were finally included. Four RCTs used patient-specific instrument, and one RCT used navigation. Data were extracted and meta-analysis was conducted. KATKA patients had better outcomes: Mean difference between KATKA and MATKA and p-value are presented in brackets after each variable: the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) (-12.5; p < 0.0001), Oxford Knee Score (OKS) (2.3; p = 0.030), combined Knee Society Score (C-KSS) (13.1; p < 0.0001), Knee Function Score (KFS) (6.4; p = 0.0070), and postoperative range of motion (ROM) (4.1°; p = 0.0010). There was no significant difference concerning the complication rates which needed reoperations or revision surgery (odds ratio, 1.01; p = 0.99). KATKA components had a more femoral valgus (-1.8°; p < 0.0001), more tibial varus (1.2°; p = 0.0001), and more tibial slope (1.2°; p = 0.0001), all being statistically significantly different. Better clinical outcomes were obtained in KATKA and component placement in KATKA is significantly different from that in MATKA. There was no increase of patients with poor clinical results due to implant position especially for varus placement of tibial component. This systematic review of five RCTs suggests that KATKA is of potential alternative method to MATKA since the risk of revision for tibial loosening is negligible compared with MATKA for the same follow-up period. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2018        PMID: 29444542     DOI: 10.1055/s-0038-1632378

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  9 in total

1.  Pathologic mechanism of hidden blood loss after total knee arthroplasty: oxidative stress induced by free fatty acids.

Authors:  Tao Yuan; Shaoqiang Yang; Chengteng Lai; Xin Yu; Hong Qian; Jia Meng; Nirong Bao; Jianning Zhao
Journal:  Int J Clin Exp Pathol       Date:  2022-03-15

Review 2.  [Kinematic alignment-management of deformities and flexion contractures].

Authors:  M Malavolta; K Kley
Journal:  Orthopade       Date:  2021-03       Impact factor: 1.087

3.  Combining kinematic alignment and medial stabilized design in total knee arthroplasty: Basic rationale and preliminary clinical evidences.

Authors:  Salvatore Risitano; Luigi Sabatini; Luca Barberis; Federico Fusini; Michele Malavolta; Pier Francesco Indelli
Journal:  J Orthop       Date:  2020-08-27

4.  Linked kinematic knee balancing in unicompartmental knee arthroplasty.

Authors:  Ryan Mortman; Casey Gioia; Seth Stake; Peter Z Berger; Alex Gu; Safa C Fassihi; Kamran N Sadr; Evan H Argintar
Journal:  J Orthop       Date:  2021-02-20

5.  Less gap imbalance with restricted kinematic alignment than with mechanically aligned total knee arthroplasty: simulations on 3-D bone models created from CT-scans.

Authors:  William Blakeney; Yann Beaulieu; Marc-Olivier Kiss; Charles Rivière; Pascal-André Vendittoli
Journal:  Acta Orthop       Date:  2019-10-15       Impact factor: 3.717

6.  Three-year clinical and radiological results of a cruciate-retaining type of the knee prosthesis with anatomical geometry developed in Japan.

Authors:  Arata Nakajima; Manabu Yamada; Masato Sonobe; Yorikazu Akatsu; Masahiko Saito; Keiichiro Yamamoto; Junya Saito; Masaki Norimoto; Keita Koyama; Hiroshi Takahashi; Yasuchika Aoki; Toru Suguro; Koichi Nakagawa
Journal:  BMC Musculoskelet Disord       Date:  2021-03-03       Impact factor: 2.362

7.  Safety and Efficacy of Single Condylar Knee Prosthesis When Treating Knee Single Compartment Osteoarthritis: A Prospective, Case-Randomized Controlled Study.

Authors:  Shaofeng Wang; Yang Wang; Jiong Wang
Journal:  Comput Intell Neurosci       Date:  2022-07-30

8.  Accurate determination of post-operative 3D component positioning in total knee arthroplasty: the AURORA protocol.

Authors:  Edgar A Wakelin; Linda Tran; Joshua G Twiggs; Willy Theodore; Justin P Roe; Michael I Solomon; Brett A Fritsch; Brad P Miles
Journal:  J Orthop Surg Res       Date:  2018-10-30       Impact factor: 2.359

9.  Arthroplasty of the Knee: Current Techniques for Implant Alignment.

Authors:  Patrick Weber; Hans Gollwitzer
Journal:  Z Orthop Unfall       Date:  2021-03-01       Impact factor: 0.923

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.