| Literature DB >> 32935824 |
Mauro Costa Morais Tavares-Júnior1, Fernando Barbosa Sanchez1, Jaime David Uquillas Iturralde1, Renan Jose Rodrigues Fernandes1, Raphael Martus Marcon1, Alexandre Fogaça Cristante1, Tarcisio Eloy Pessoa de Barros-Filho1, Olavo Biraghi Letaif2.
Abstract
OBJECTIVES: The recent advancements in spine fixation aid in the treatment of complex spinal pathologies. Both the iliac screw (IS) and the S2-alar-iliac (S2AI) screw provide adequate stability in the fixation of complex lumbosacral spine pathologies, leading to a significant increased rate of using these techniques in the daily practice of the spine surgeons. This study aims to analyze, describe, and compare the insertion and positioning parameters of the S2AI screw and IS techniques in children without spinal deformities.Entities:
Mesh:
Year: 2020 PMID: 32935824 PMCID: PMC7470428 DOI: 10.6061/clinics/2020/e1824
Source DB: PubMed Journal: Clinics (Sao Paulo) ISSN: 1807-5932 Impact factor: 2.365
Figure 1Example of the S2-alar-iliac screw (shown by the red cross) and the iliac screw (shown by the white cross) entry points.
Figure 2Example of iliac screw length measurement (shown by white line).
Figure 3Example of distance from skin iliac screw measurement (shown by red line).
Figure 4Example of S2AI screw length (shown by red line).
Figure 5Example of S2AI screw length on CT 3D (shown by white line).
Mann-Whitney and Shapiro-Wilk tests.
| Data | Iliac | S2AI | Mean difference iliac x S2AI | Standard deviation | 95% confidence interval (CI) - superior limit | 95% confidence interval (CI) - inferior limit |
|
|---|---|---|---|---|---|---|---|
| Screw length | 106.63 | 104.13 | 2.50 | 4.18 | 4.23 | 0.77 | <0.01 |
| Maximum bone thickness | 22.62 | 23.77 | -1.15 | 1.40 | -0.57 | -1.72 | <0.01 |
| Minimum bone thickness | 14.02 | 18.18 | -4.16 | 1.41 | -3.58 | -4.75 | <0.01 |
| Axial screw angle | 24.06 | 31.96 | -7.90 | 1.33 | -7.35 | -8.45 | <0.01 |
| Sagittal screw angle | 29.86 | 30.50 | -0.63 | 3.22 | 0.70 | -1.96 | 0.341 |
| Distance from skin | 28.13 | 39.96 | -11.84 | 5.26 | -9.66 | -14.01 | <0.01 |
Comparison of the intraclass correlation coefficients.
| Data | Intraclass correlation | 95% confidence interval (CI) - superior limit | 95% confidence interval (CI) - inferior limit |
|---|---|---|---|
| Screw length | |||
| Iliac | 0.984 | 0.992 | 0.971 |
| S2AI | 0.951 | 0.976 | 0.913 |
| Maximum bone thickness | |||
| Iliac | 0.840 | 0.917 | 0.732 |
| S2AI | 0.848 | 0.922 | 0.745 |
| Minimum bone thickness | |||
| Iliac | 0.771 | 0.878 | 0.631 |
| S2AI | 0.774 | 0.879 | 0.635 |
| Axial screw angle | |||
| Iliac | 0.774 | 0.862 | 0.594 |
| S2AI | 0.767 | 0.876 | 0.626 |
| Sagittal screw angle | |||
| Iliac | 0.798 | 0.893 | 0.670 |
| S2AI | 0.756 | 0.869 | 0.611 |
| Distance from skin | |||
| Iliac | 0.972 | 0.986 | 0.950 |
| S2AI | 0.954 | 0.977 | 0.918 |
Interpretation: less than 0.400: poor; 0.400-0.599: fair; 0.600-0.749: good; and 0.750-1.00: excellent.
Comparison of the Pearson’s correlation Coefficients.
| Data | Pearson’s correlation coefficient |
|
|---|---|---|
| Screw length | ||
| Iliac | 0.915 | <0.01 |
| S2AI | 0.904 | <0.01 |
| Maximum bone thickness | ||
| Iliac | 0.545 | 0.005 |
| S2AI | 0.593 | <0.01 |
| Minimum bone thickness | ||
| Iliac | 0.694 | <0.01 |
| S2AI | 0.796 | <0.01 |
| Axial screw angle | ||
| Iliac | -0.330 | 0.107 |
| S2AI | -0.243 | 0.242 |
| Sagittal screw angle | ||
| Iliac | 0.059 | 0.778 |
| S2AI | 0.008 | 0.971 |
| Distance from skin | ||
| Iliac | 0.345 | 0.091 |
| S2AI | 0.466 | 0.019 |