Literature DB >> 32935593

Comparison of the Visual Performance after Implantation of Three Aberration-correcting Aspherical Intraocular Lens.

Yuqi Liu1, Jiangyue Zhao1, Yiping Hu1, Bowen Li1, Jing Wang1,2, Jinsong Zhang1,2.   

Abstract

PURPOSE: To compare the visual performance after implantation of three aberration-correcting aspherical intraocular lens (IOL).
MATERIALS AND METHODS: Seventy-seven eyes of 77 cataract patients were divided into three groups: 26 eyes implanted with a non-constant aberration IOL (LUCIA 601P IOL, Zeiss Company, Germany); 26 eyes implanted with a spherical aberration -0.18μm IOL (CT ASPHINA 509M, Zeiss Company, Germany) and 27 eyes implanted with a spherical aberration -0.27μm IOL (AMO Tecnis ZCB00, Johnson & Johnson Surgical Vision, USA). Three months after operation, the distance visual acuity, wavefront aberrometry, contrast sensitivity, intraocular stray light, IOL decentration, and tilt were evaluated.
RESULTS: Three months postoperatively, no statistically significant differences were found in uncorrected distance visual acuity and corrected distance visual acuity (p≥.83). The RMS for total ocular coma was statistically significantly lower in the Lucia group (p=.03) and spherical aberration was statistically significantly lower in the Tecnis group (p<.01). No statistically significant differences were observed among the three lenses in higher order aberration (p=.85) and in contrast sensitivity under both photopic and mesopic lighting conditions (p≥.05). The intraocular stray light was statistically significantly better in the Lucia group (p=.04). No statistically significant differences were observed with respect to IOL decentration (p=.75) and tilt (p=.89).
CONCLUSIONS: Cataract surgery with non-constant aberration IOL resulted in lower coma and better intraocular stray light than with the spherical aberration -0.18μm and -0.27μm IOLs despite equivalent postoperative levels of visual acuity and contrast sensitivity.

Entities:  

Keywords:  Intraocular lens; contrast sensitivity; non-constant aberration; spherical aberration; wavefront aberrometry

Mesh:

Year:  2020        PMID: 32935593     DOI: 10.1080/02713683.2020.1798467

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  3 in total

1.  Clinical and Aberrometric Evaluation of a New Monofocal IOL with Intermediate Vision Improvement.

Authors:  Alessandro Bova; Stefano Vita
Journal:  J Ophthalmol       Date:  2022-07-07       Impact factor: 1.974

2.  Refractive and Visual Outcomes of a Monofocal Non-Constant Aberration Aspheric Intraocular Lens.

Authors:  Adrián Hernández-Martínez; Miguel A Díaz-Del-Rio; María Ruiz-Santos; Ramón Ruiz-Mesa; Pedro Tañá-Rivero
Journal:  Clin Ophthalmol       Date:  2022-08-10

3.  Outcomes of a multicenter U.S. clinical trial of a new monofocal single-piece hydrophobic acrylic IOL.

Authors:  Steven C Schallhorn; Michael Bonilla; Seth M Pantanelli
Journal:  J Cataract Refract Surg       Date:  2022-03-25       Impact factor: 3.528

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.