Literature DB >> 32895856

Development, diagnostic performance, and interobserver agreement of a 18F-flurpiridaz PET automated perfusion quantitation system.

René R Sevag Packard1, C David Cooke2,3, Kenneth F Van Train3, John R Votaw2, James W Sayre4, Joel L Lazewatsky5, Kelly M Champagne3, Cesare Orlandi5, Ernest V Garcia2, Jamshid Maddahi6,7.   

Abstract

BACKGROUND: Computerized methodologies standardize the myocardial perfusion imaging (MPI) interpretation process.
METHODS: To develop an automated relative perfusion quantitation approach for 18F-flurpiridaz, PET MPI studies from all phase III trial participants of 18F-flurpiridaz were divided into 3 groups. Count distributions were obtained in N = 40 normal patients undergoing pharmacological or exercise stress. Then, N = 90 additional studies were selected in a derivation group. Following receiver operating characteristic curve analysis, various standard deviations below the mean normal were used as cutoffs for significant CAD, and interobserver variability determined. Finally, diagnostic performance was compared between blinded visual readers and blinded derivations of automated relative quantitation in the remaining N = 548 validation patients.
RESULTS: Both approaches yielded comparable accuracies for the detection of global CAD, reaching 71% and 72% by visual reads, and 72% and 68% by automated relative quantitation, when using CAD ≥ 70% or ≥ 50% stenosis for significance, respectively. Similar results were observed when analyzing individual coronary territories. In both pharmacological and exercise stress, automated relative quantitation demonstrated significantly more interobserver agreement than visual reads.
CONCLUSIONS: Our automated method of 18F-flurpiridaz relative perfusion analysis provides a quantitative, objective, and highly reproducible assessment of PET MPI in normal and CAD subjects undergoing either pharmacological or exercise stress.
© 2020. American Society of Nuclear Cardiology.

Entities:  

Keywords:  Flurpiridaz; PET MPI; automated relative quantitation; diagnostic performance; interobserver variability

Mesh:

Substances:

Year:  2020        PMID: 32895856      PMCID: PMC7936994          DOI: 10.1007/s12350-020-02335-6

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  30 in total

1.  Quantitative (82)Rb PET/CT: development and validation of myocardial perfusion database.

Authors:  Cesar A Santana; Russell D Folks; Ernest V Garcia; Liudmila Verdes; Rupan Sanyal; Jon Hainer; Marcelo F Di Carli; Fabio P Esteves
Journal:  J Nucl Med       Date:  2007-06-15       Impact factor: 10.057

2.  Phase I, first-in-human study of BMS747158, a novel 18F-labeled tracer for myocardial perfusion PET: dosimetry, biodistribution, safety, and imaging characteristics after a single injection at rest.

Authors:  Jamshid Maddahi; Johannes Czernin; Joel Lazewatsky; Sung-Cheng Huang; Magnus Dahlbom; Heinrich Schelbert; Richard Sparks; Alexander Ehlgen; Paul Crane; Qi Zhu; Marybeth Devine; Michael Phelps
Journal:  J Nucl Med       Date:  2011-08-17       Impact factor: 10.057

3.  Prognostic value of PET myocardial perfusion imaging in obese patients.

Authors:  Benjamin J W Chow; Sharmila Dorbala; Marcelo F Di Carli; Michael E Merhige; Brent A Williams; Emir Veledar; James K Min; Michael J Pencina; Yeung Yam; Li Chen; Sai Priya Anand; Terrence D Ruddy; Daniel S Berman; Leslee J Shaw; Rob S Beanlands
Journal:  JACC Cardiovasc Imaging       Date:  2014-02-19

4.  Interpretive reproducibility of stress Tc-99m sestamibi tomographic myocardial perfusion imaging.

Authors:  R J Golub; A W Ahlberg; J R McClellan; S D Herman; M I Travin; J F Mather; P W Aitken; J I Baron; G V Heller
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

Review 5.  Cardiac PET perfusion tracers: current status and future directions.

Authors:  Jamshid Maddahi; René R S Packard
Journal:  Semin Nucl Med       Date:  2014-09       Impact factor: 4.446

Review 6.  Clinical decision support systems in myocardial perfusion imaging.

Authors:  Ernest V Garcia; J Larry Klein; Andrew T Taylor
Journal:  J Nucl Cardiol       Date:  2014-01-31       Impact factor: 5.952

Review 7.  Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease?: A systematic review and meta-analysis.

Authors:  Brian A Mc Ardle; Taylor F Dowsley; Robert A deKemp; George A Wells; Rob S Beanlands
Journal:  J Am Coll Cardiol       Date:  2012-10-03       Impact factor: 24.094

8.  Regadenoson induces comparable left ventricular perfusion defects as adenosine: a quantitative analysis from the ADVANCE MPI 2 trial.

Authors:  John J Mahmarian; Manuel D Cerqueira; Ami E Iskandrian; Timothy M Bateman; Gregory S Thomas; Robert C Hendel; Lemuel A Moye; Ann W Olmsted
Journal:  JACC Cardiovasc Imaging       Date:  2009-08

9.  Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

Authors:  Timothy M Bateman; Gary V Heller; A Iain McGhie; John D Friedman; James A Case; Jan R Bryngelson; Ginger K Hertenstein; Kelly L Moutray; Kimberly Reid; S James Cullom
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

10.  Added value of myocardial blood flow using 18F-flurpiridaz PET to diagnose coronary artery disease: The flurpiridaz 301 trial.

Authors:  Venkatesh L Murthy; Edward P Ficaro; Jonathan B Moody; Alexis Poitrasson-Rivière; Tomoe Hagio; Christopher Buckley; Richard L Weinberg; James R Corbett
Journal:  J Nucl Cardiol       Date:  2020-01-30       Impact factor: 5.952

View more
  4 in total

1.  Automation in Nuclear Cardiology: Time for Flurpiridaz to Join the Club.

Authors:  Ahmed Aljizeeri; Firas Al Badarin; Mouaz H Al-Mallah
Journal:  J Nucl Cardiol       Date:  2020-11-17       Impact factor: 5.952

2.  Rest/stress myocardial perfusion imaging by positron emission tomography with 18F-Flurpiridaz: A feasibility study in mice.

Authors:  Susan Bengs; Geoffrey I Warnock; Catherine Gebhard; Ahmed Haider; Angela Portmann; Nidaa Mikail; Alexia Rossi; Hazem Ahmed; Dominik Etter; Valerie Treyer; Livio Gisler; Stefanie K Pfister; Caitlin V M L Jie; Alexander Meisel; Claudia Keller; Steven H Liang; Roger Schibli; Linjing Mu; Ronny R Buechel; Philipp A Kaufmann; Simon M Ametamey
Journal:  J Nucl Cardiol       Date:  2022-04-28       Impact factor: 5.952

Review 3.  Novel Tracers and Radionuclides in PET Imaging.

Authors:  Christian Mason; Grayson R Gimblet; Suzanne E Lapi; Jason S Lewis
Journal:  Radiol Clin North Am       Date:  2021-09       Impact factor: 1.947

4.  Diagnostic Performance of PET Versus SPECT Myocardial Perfusion Imaging in Patients with Smaller Left Ventricles: A Substudy of the 18F-Flurpiridaz Phase III Clinical Trial.

Authors:  René R Sevag Packard; Joel L Lazewatsky; Cesare Orlandi; Jamshid Maddahi
Journal:  J Nucl Med       Date:  2020-11-27       Impact factor: 10.057

  4 in total