| Literature DB >> 32894106 |
Christian Pfeifle1,2, Melanie Edel3,4, Stefan Schleifenbaum3,4, Andreas Kühnapfel5, Christoph-Eckhard Heyde3,4.
Abstract
BACKGROUND: The presence of muscular deficiency seems to be a major cause of back pain that requires counteractions. Considering that the autochthonous back muscles, responsible for straightening and stabilizing the spine, cannot be activated voluntarily, they can be strengthened only through specific training. The computer-supported test and training system (CTT) Centaur (BfMC GmbH, Leipzig, SN, Germany) seems well suited for this purpose. To show its potential as a reliable diagnostic and training tool, this study aimed to evaluate the test-retest reliability of this 3D spatial rotation device.Entities:
Keywords: Autochthonous musculature; BfMC; CTT centaur; Computer-supported diagnosis; Low back pain; Reliability
Mesh:
Year: 2020 PMID: 32894106 PMCID: PMC7487624 DOI: 10.1186/s12891-020-03597-4
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Inclusion and exclusion criteria
| Inclusion Criteria | Exclusion Criteria |
|---|---|
| Aged 18–75 years | Pregnancy |
| Body mass ≤ 130 kg | Tumor disease |
| Participation in all sessions | Recent bone fracture (in the last 6 months) |
| Constant lifestyle regarding medication consumption, | Recent operation (in the last 6 months) |
| Nutrition, sports participation, etc. | Findings suggesting the need for acute surgery |
| Spinal stiffening operation | |
| Spinal deformity | |
| Scar hernia | |
| Severe vascular disorder | |
| Severe inflammatory disorder | |
| Manifest and advanced osteoporosis | |
| Dementia | |
| Known heart failure > NYHA Class 2 | |
| Existing therapeutic anticoagulation | |
| Pre-existing paraesthesia | |
| Osteoporotic vertebral sintering | |
| Fresh prolapse of the intervertebral disc | |
| Pre-existing motor nerve damage | |
| Dizziness and known kinetosis tendency | |
| Retinal detachment | |
| Infectious diseases | |
| Simultaneous interventional study participation |
Fig. 1CTT Centaur with the subject tilted in the sagittal plane (transverse plane: 0°)
Fig. 2Measurement positions (transverse plane) of the one-minute endurance test (arrow: tilt direction in the sagittal plane)
Fig. 5Example of a subject’s movement profile with an interside comparison (upper table), representation of the time-dependent deviation and all upper body movements for one measurement assessed by CTT Centaur software
Fig. 3Example of a subject’s upper body movement with the calculated 95% confidence ellipses (green) for one measurement, calculated according to the subject’s position in the transverse plane
Sex-specific characteristics of the study group
| Sex | Minimum | Maximum | Mean | Standard Deviation | |
|---|---|---|---|---|---|
| Age in years | m | 23.0 | 43.8 | 31.7 | 6.31 |
| f | 21.4 | 37.0 | 27.5 | 4.33 | |
| Height in m | m | 1.80 | 1.92 | 1.84 | 0.04 |
| f | 1.60 | 1.83 | 1.70 | 0.08 | |
| Average mass in kg | m | 64.0 | 99.8 | 81.8 | 12.05 |
| f | 53.8 | 83.1 | 70.2 | 9.97 | |
| BMI in kg/m2 | m | 19.8 | 29.8 | 24.2 | 3.53 |
| f | 19.7 | 29.9 | 24.2 | 3.51 |
Characteristics of the 95% confidence ellipse areas for each measurement and the results of the normality test (p)
| Area a in mm2 | Minimum | Maximum | Mean | Standard Deviation | |
|---|---|---|---|---|---|
| t1 | 0.14 | 0.92 | 0.5297 | 0.2221 | 0.638 |
| t2 | 0.12 | 0.82 | 0.5034 | 0.2336 | 0.099 |
| t3 | 0.14 | 1.00 | 0.5336 | 0.2248 | 0.732 |
a Consideration of the sqrt transformed standardized data
ICC estimates with the 95% confidence intervals for all the pairs of time points
| Measurement a | Intraclass Correlation | 95%-Confidence Interval | |
|---|---|---|---|
| Lower Bound | Upper Bound | ||
| t1, t2, t3 | 0.805 | 0.643 | 0.910 |
| t1, t2 | 0.795 | 0.555 | 0.913 |
| t1, t3 | 0.779 | 0.519 | 0.907 |
| t2, t3 | 0.840 | 0.645 | 0.933 |
a Consideration of the sqrt transformed standardized data
Fig. 4Bland-Altman plots of all the pairs of time points, including the limits of agreement ( ), regression lines (―), and 95% confidence interval (- - -)
Bland-Altman analysis
| Measurement a | Mean Bias | Standard Deviation | Limits of Agreement (Mean Bias ±1,96 ▪ SD) | |
|---|---|---|---|---|
| Lower Limit | Upper Limit | |||
| t1, t2 | 0.026 | 0.147 | −0.262 | 0.315 |
| t1, t3 | −0.004 | 0.151 | −0.301 | 0.293 |
| t2, t3 | −0.030 | 0.129 | −0.284 | 0.223 |
a Consideration of the sqrt transformed standardized data