Literature DB >> 32887150

Detection of cardiac troponin-I by optic biosensors with immobilized anti-cardiac troponin-I monoclonal antibody.

Duygu Çimen1, Nilay Bereli1, Serdar Günaydın2, Adil Denizli3.   

Abstract

In this study, it is aimed to determine cardiac troponin I by a surface plasmon resonance biosensor immobilized anti-cardiac troponin I monoclonal antibody. The immobilized anti-cardiac troponin I monoclonal antibody surface plasmon resonance biosensors were characterized with ellipsometry, atomic force microscopy and contact angle analysis. After that, surface plasmon resonance biosensor system was completed to biosensor system to investigate kinetic properties for cardiac tropinin I. The sensing ability of surface plasmon resonance biosensor was investigated with 0.001-8.0 ng/mL concentrations of cardiac tropinin I solutions. The limit of detection and limit of quantification were calculated as 0.00012 ng/mL and 0.00041 ng/mL, respectively. To show the selectivity of surface plasmon resonance biosensor competitive adsorption of cardiac tropinin I, myoglobin, immunoglobulin G and prostate specific antigen were investigated. Surface plasmon resonance biosensor was investigated five times with 0.5 ng/mL concentrations of cardiac tropinin I solution to show reuse of the chip. The results showed that surface plasmon resonance biosensor has high selectivity for cardiac tropinin I. The reproducibility of surface plasmon resonance sensors was investigated both on the same day and on different days for five times. To determine the usability, selectivity and validation studies of surface plasmon resonance biosensors were performed by enzyme-linked immunosorbent assay method.
Copyright © 2020. Published by Elsevier B.V.

Entities:  

Keywords:  Biomarker; Biosensor; Cardiac tropinin I; Diagnosis; Surface plasmon resonance

Mesh:

Substances:

Year:  2020        PMID: 32887150     DOI: 10.1016/j.talanta.2020.121259

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Fluorescence Based on Surface Plasmon Coupled Emission for Ultrahigh Sensitivity Immunoassay of Cardiac Troponin I.

Authors:  Vien Thi Tran; Heongkyu Ju
Journal:  Biomedicines       Date:  2021-04-21

2.  Surface Plasmon Resonance Based on Molecularly Imprinted Polymeric Film for l-Phenylalanine Detection.

Authors:  Duygu Çimen; Nilay Bereli; Adil Denizli
Journal:  Biosensors (Basel)       Date:  2021-01-15

3.  A Novel Graphene-Based Nanomaterial Modified Electrochemical Sensor for the Detection of Cardiac Troponin I.

Authors:  Jing Li; Shenwei Zhang; Li Zhang; Yu Zhang; Hua Zhang; Chuanxi Zhang; Xuexi Xuan; Mingjie Wang; Jinying Zhang; Yiqiang Yuan
Journal:  Front Chem       Date:  2021-05-14       Impact factor: 5.221

4.  Consistency analysis of high-sensitivity cardiac troponin I in peripheral blood and venous blood by quantum dot immunofluorescence assay and clinical application in acute myocardial infarction.

Authors:  Haohao Liu; Fang Luo; Lizhu Zhang; Zhijun Han; Mingxiang Shao; Hong Du
Journal:  J Thorac Dis       Date:  2022-04       Impact factor: 2.895

Review 5.  Cardiac Troponin Biosensor Designs: Current Developments and Remaining Challenges.

Authors:  Andreea Campu; Ilinca Muresan; Ana-Maria Craciun; Simona Cainap; Simion Astilean; Monica Focsan
Journal:  Int J Mol Sci       Date:  2022-07-13       Impact factor: 6.208

Review 6.  Recent Advances of Optical Sensors for Copper Ion Detection.

Authors:  Zeynep Gerdan; Yeşeren Saylan; Adil Denizli
Journal:  Micromachines (Basel)       Date:  2022-08-11       Impact factor: 3.523

  6 in total