Modern Revision Femoral Stem Designs Have No Difference in Rates of Subsidence.

Steven Yacovelli1, Jesse Ottaway1, Samik Banerjee1, P Maxwell Courtney1.   

Abstract

BACKGROUND: Both modular and monoblock tapered fluted titanium (TFT) stems have gained popularity over fully porous-coated cylindrical (FPCC) femoral stem designs, but limited data exist comparing subsidence rates following revision total hip arthroplasty (THA). The purpose of this study is to determine differences in subsidence and clinical outcomes among 3 revision femoral stem designs.
METHODS: We reviewed a consecutive series of 335 patients who underwent femoral component revision to a cementless modular TFT (n = 225), monoblock TFT (n = 63), or FPCC (n = 47) stem between 2012 and 2019. We evaluated radiographic subsidence rates, re-revision rates, and patient-reported outcomes between the 3 stems. A multivariate regression analysis was performed to determine the independent effect of stem type on the risk of subsidence >5 mm.
RESULTS: At an average follow-up of 39 months (range, 12 to 96 months), there were no differences in mean subsidence rates (3.5 vs 2.4 vs 2.1 mm, P = .14), HOOS Jr scores (78 vs 74 vs 64 points, P = .15), or aseptic re-revision rates (4% vs 3% vs 0%, P = .29) between modular TFT, monoblock TFT, and FPCC stems. Although modular TFT stems were more often used in patients with extensive femoral bone loss (Paprosky III and IV), there were no differences in subsidence rates >5 mm among the 3 stems (P > .05) in multivariate analysis.
CONCLUSION: Modular TFT, monoblock TFT, and FPCC femoral stem designs all perform well in revision THA with no difference in clinical outcomes or subsidence rates. Surgeons should select the stem which they feel is the most clinically appropriate.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  femoral revision; fully porous-coated stem; revision hip arthroplasty; stem design; tapered fluted titanium stem

Year:  2020        PMID: 32863074     DOI: 10.1016/j.arth.2020.07.078

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  2 in total

1.  Minimum ten-year results in revision total hip arthroplasty using titanium fully porous long stem.

Authors:  Masahiro Hasegawa; Shine Tone; Yohei Naito; Hiroki Wakabayashi; Akihiro Sudo
Journal:  Int Orthop       Date:  2021-04-07       Impact factor: 3.075

2.  Subsidence of monoblock and modular titanium fluted tapered stems in revision hip arthroplasty: A retrospective multicentre comparison study.

Authors:  Eoghan Pomeroy; Seán O Flynn; Mihai Grigoras; Terence P Murphy; Alexandra I Stavrakis; Fiachra E Rowan
Journal:  J Clin Orthop Trauma       Date:  2022-09-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.