Literature DB >> 3286002

Non-invasive measurement of renal blood flow with 99mTc DTPA: comparison with radiolabelled microspheres.

A M Peters1, J Brown, G G Hartnell, M J Myers, C Haskell, J P Lavender.   

Abstract

This technique for non-invasive measurement of renal blood flow is based on the principle of fractionation of cardiac output, and applicable with any recirculating gamma activity tracer. It effectively determines the count rate that would be recorded over the kidney if the tracer behaved like radiolabelled microspheres and was completely trapped in the kidney on first pass. After correction for kidney depth, the estimated first pass activity plateau, expressed as a fraction of the injected dose, is equal to the kidney's fraction of cardiac output. The principle of the technique was validated by comparison with renal blood flow based on radiolabelled microspheres. Nine separate comparisons were made in two anaesthetised dogs. A known dose of 99mTc radiolabelled microspheres (particle size 23-45 microns) was injected into the left ventricle and the count rate over each kidney recorded. A known dose of 99mTc diethylenetriaminepenta acetic acid (DTPA) was then given as an intravenous bolus and the data recorded dynamically with a gamma camera online to a computer. After subtraction of the stable signal arising from the preceding radiolabelled microspheres, the theoretical first pass activity plateau from the DTPA that would have been recorded if the DTPA, after reaching the systemic circulation, had behaved like radiolabelled microspheres and become completely trapped in the renal vascular bed, was estimated. Using doses based on syringe counts before and after injection the ratio of renal blood flow values given by the two techniques (DTPA:RLMS) was 1.14 (SD 0.22) for the left kidney and 1.1(0.17) for the right. Using doses based on whole body counts, corresponding ratios were 1.05(0.11) and 1.02(0.13).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3286002     DOI: 10.1093/cvr/21.11.830

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  7 in total

1.  Quantification of right to left shunt at rest and during exercise in patients with pulmonary arteriovenous malformations.

Authors:  M K Whyte; A M Peters; J M Hughes; B L Henderson; G J Bellingan; J E Jackson; E R Chilvers
Journal:  Thorax       Date:  1992-10       Impact factor: 9.139

2.  Repeatability of renal arterial spin labelling MRI in healthy subjects.

Authors:  Marica Cutajar; David L Thomas; Tina Banks; Christopher A Clark; Xavier Golay; Isky Gordon
Journal:  MAGMA       Date:  2012-01-13       Impact factor: 2.310

3.  Evaluation of flow measurement from the first pass bolus T1 weighted images using inversion recovery sequence.

Authors:  M Nazarpoor
Journal:  Br J Radiol       Date:  2010-10-19       Impact factor: 3.039

Review 4.  Quantification of renal haemodynamics with radionuclides.

Authors:  A M Peters
Journal:  Eur J Nucl Med       Date:  1991

5.  Measurement of blood flow from first-pass radionuclide angiography: influence of bolus volume.

Authors:  S D Bell; A M Peters
Journal:  Eur J Nucl Med       Date:  1991

6.  Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility.

Authors:  Marica Cutajar; David L Thomas; Patrick W Hales; T Banks; Christopher A Clark; Isky Gordon
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

7.  Combined renal MRA and perfusion with a single dose of contrast.

Authors:  Parmede Vakil; James C Carr; Timothy J Carroll
Journal:  Magn Reson Imaging       Date:  2012-04-20       Impact factor: 2.546

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.