| Literature DB >> 32859195 |
Charles Caraguel1, Sarah Bassett1, David González-Barrio2, Peter Elsworth3, Anne-Lise Chaber4.
Abstract
BACKGROUND: Coxiella burnetii causes Q fever, a zoonotic bacterial disease with a multi-host cycle and reservoirs in wild and domestic animal species. Q fever has a significant impact on the Australian public health and economy but its ecology and contributing reservoir species remain poorly understood. In Europe, rabbits (Oryctolagus cuniculus) were identified as a major reservoir of C. burnetii and it is possible that they play a similar role in Australia. In absence of commercial kit available for rabbit, the Thermo Fisher - PrioCHECK™ Ruminant Q fever Ab Plate Kit was adapted to successfully screen rabbits population in Europe. However, this assay is not accessible in Australia and we assessed the equivalency of two commercially available kits in Australia - IDEXX - CHEKIT Q Fever Antibody ELISA kit and IDVet - ID Screen® Q Fever Indirect Multi-species with the Thermo Fisher kit (reference kit).Entities:
Keywords: Coxiella burnetii; ELISA; European rabbit; Oryctolagus cuniculus; Q fever; Serology
Mesh:
Substances:
Year: 2020 PMID: 32859195 PMCID: PMC7456029 DOI: 10.1186/s12917-020-02526-w
Source DB: PubMed Journal: BMC Vet Res ISSN: 1746-6148 Impact factor: 2.741
Pearson’s correlarion coefficient (r), bias-corretion factor (C), concordance correlation coefficient (r = r x C), reduced major axis slope and intercept estimates for each pairwise comparison of sample-to-positve ratios between CHEKIT Q Fever Antibody ELISA kit (IDEXX), ELISA kits - PrioCHECK™ Ruminant Q fever Ab Plate Kit (Thermo Fisher) and ID Screen® Q Fever Indirect Multi-species (IDvet)
| Pairwise comparisons | Pearson’s correlarion coefficient ( | Bias-correction factor ( | Concordance correlation coefficient ( | Regression slope | Regression intercept |
|---|---|---|---|---|---|
| IDEXX vs. Thermo Fisher | 0.883 | 0.871 | 0.769 | 0.594 | −0.030 |
| IDvet vs. Thermo Fisher | 0.969 | 0.957 | 0.927 | 1.021 | 0.056 |
| IDEXX vs. IDvet | 0.844 | 0.776 | 0.654 | 0.582 | −0.062 |
Fig. 1Concordance plots of the sample-to-positive ratios (S/P) between CHEKIT Q Fever Antibody ELISA kit (IDEXX kit) and PrioCHECK™ Ruminant Q fever Ab Plate Kit (Thermo Fisher kit) (a) or ID Screen® Q Fever Indirect Multi-species (IDVet kit) (b), and between IDVet and Thermo Fisher kits (c). The continuous line is the fitted regression line and the dotted line is the identity line. Using manufacturers’ guidelines for ruminants, illustrative S/P cutoff values were set at 0.3 (dashed line) and 0.4 (dash-dotted line) – S/P < 0.3: seronegative; S/P ≥ 0.3 and < 0.4: borderline; S/P ≥ 0.4: seropositive